ArcSystem Pro D1 and D2 Series Drivers Installation Guide Part Number: 7490M2180 Rev: C Released: 2024-06...
Page 2
To view a list of ETC trademarks and patents, go to etcconnect.com/ip. All other trademarks, both marked and not marked, are the property of their respective owners. For a complete list of all third-party licenses that are fully incorporated herein to the extent required by each third-party license terms and conditions, please visit etcconnect.com/licenses.
D1 and D2 Series Drivers, and full system integration. For more information on ArcMesh, the D1 Driver Quick Connect, or other ArcSystem Pro drivers and luminaires, see the manuals listed below. All ETC manuals are available for download free of charge at etcconnect.com.
Label Symbols ArcSystem luminaires and drivers are conveniently labeled with relevant symbols for your safety. Refer to the product label to see which symbols apply to your product. General warning Avertissement général This product should not be discarded as unsorted Ce produit ne doit pas être jeté...
System Overview Models are available to meet your installation requirements. This guide covers the products listed below. For complete specifications, view the product datasheets at etcconnect.com/ArcSystem. ArcSystem Pro One-Cell Luminaires Model Mounting Options Driver Power Input Options • 100–277 VAC, 50/60Hz hard-wired (non- emergency models) D1 Series •...
Page 6
D1 Series, D2 Series, and D4 Series Drivers D1 Driver D1 HO Driver D2 Driver Wall-Mount D4 Driver 150 (also available in 350 and 700 models) Rack-Mount D4 Driver 350 (also available in 700 model) Note: Antenna is not present on RDM models. ArcSystem Pro One-Cell luminaires require an external driver.
Page 7
Emergency System Overview ArcSystem drivers and luminaires can be purchased in UL924 listed variants. Each of the luminaires can be configured to be UL924 listed when wired into an existing emergency Emergency System One-Cell Installation on page 19 response system. See Install the luminaire and ArcSystem D1, D2, or D4 Series driver in a location that is accessible by qualified personnel for testing of the emergency operation.
Typical Installation The typical installation shown below is suitable for all ArcSystem Pro emergency drivers and ArcSystem Pro multi-cell emergency luminaires. ArcSystem Pro normal normal normal branch circuit multi-cell emergency Sense breaker used to sense normal power failure luminaire or panel ArcSystem Pro One-Cell luminaire...
WARNING: RISK OF DEATH BY ELECTRIC SHOCK! Failure to disconnect all power to the system before installation, maintenance, cleaning, or any other system modification could result in serious injury or death. AVERTISSEMENT : RISQUE DE MORT PAR DÉCHARGE ÉLECTRIQUE! Négliger de débrancher toutes les sources d’alimentation du système avant l’installation, l’entretien, le nettoyage ou toute autre modification du système peut causer des blessures graves ou la mort.
Page 10
D1 or D1 HO driver Flexible conduit* Luminaire *ETC recommends installing all wiring for D1, D1 HO, and D2 Series drivers in grounded metal conduit. D1 Quick Connect Drivers (available in CE regions only) do not have conduit entry knockouts and can be installed without conduit. Supplies The following supplies are required, but not provided: •...
Installation Accessories Several installation accessories are available for purchase separate from the luminaire. Contact ETC or your authorized ETC dealer to purchase these accessories. • ArcSystem Recessed Luminaire Ceiling Bracket: The ArcSystem Recessed Luminaire Ceiling Bracket is intended for use in new installations or when additional support is required for hanging a luminaire.
Page 12
*ETC recommends installing all wiring for D1, D1 HO, and D2 Series drivers in grounded metal conduit. D1 Quick Connect Drivers (available in CE regions only) do not have conduit entry knockouts and can be installed without conduit. D1 & D2 Series Drivers Installation Guide...
Page 13
(see page ). Contact ETC for custom mounting bracket options. 1. Remove the two screws on the cover of the driver and set them aside. 2. Remove the driver cover. The cover is tethered to the backbox. Be careful when handling.
Page 14
D1 Driver Quick Connect Mounting Strap The mounting strap (A in the illustration to the right) has two keyholes (B) and is secured to the driver by two screws (C). If you are installing the driver to a vertical surface, the narrow end of the keyholes should point toward the ceiling.
Page 15
Preparing the Ceiling for Recessed Luminaires This section is specific to recessed (flush-mount) luminaires. For yoke-mounted luminaires, see Installing One-Cell Yoke-Mounted Luminaires on page 18 The luminaire retaining clips accommodate Luminaire Minimum Hole Diameter 3–24 mm (1/8–15/16 in) ceiling thickness. Pro One-Cell 16.5 cm (6-1/2 in) Cut a hole in the ceiling or ceiling tile to accommodate the luminaire’s retaining clip...
Page 16
Wire the Driver Wiring of the driver consists of wiring power and data (DMX) to the driver for your luminaire and then running power out to the luminaire from the driver. If you are installing emergency system drivers, see Emergency System One-Cell Installation on page 19 D1 Driver Quick D1 Driver D1 HO Driver...
Page 17
WARNING: RISK OF ELECTRIC SHOCK! Circuits that are installed without an accessible power disconnect device cannot be serviced or operated safely. AVERTISSEMENT : RISQUE DE DÉCHARGE ÉLECTRIQUE! Il est imprudent d'utiliser ou de réparer les circuits installés sans qu'un dispositif de déconnexion de l'alimentation ne soit accessible.
Page 18
ArcSystem multi-cell luminaires and standalone drivers are not self- terminating. You must terminate the last multi-cell luminaire or standalone driver in line with a 120 Ω resistor. To purchase an RJ45 terminator, please contact your ETC customer service representative and request part number N4086. DMX Connection to Driver 1.
Page 19
Installing One-Cell Recessed Luminaires The installation procedure is similar for all recessed one-cell luminaires (fixed and adjustable). For Pro One-Cell yoke-mounted luminaires, continue on to Installing One-Cell Yoke-Mounted Luminaires on the next page WARNING: ArcSystem Pro One-Cell fixtures and drivers are NON-IC rated and therefore NOT suitable for installation in direct contact with combustible materials or thermal insulation.
Page 20
Installing One-Cell Yoke-Mounted Luminaires 1. Attach a C-clamp or other mounting hardware (not provided) to the yoke of the luminaire. 2. Attach the luminaire to a pipe or other approved mounting device. (A) Center Yoke (B) Off-Center Yoke Luminaire Hole Diameter Hole Diameter 10 mm 8 mm...
Page 21
Emergency System One-Cell Installation With the exception of power input terminations, ArcSystem emergency system installation requirements are the same as those of the standard ArcSystem. Complete the appropriate steps for your installation, referencing the following sections for any additional installation details before wiring the power: Prepare to Install the D1 or D2 Series Driver on page 8 •...
D1 Quick Connect Emergency Drivers D1 Quick Connect Emergency Drivers have hard-wired power input cables with bare ends for direct connection to your maintained/emergency and normal sense power supplies. The cables are labeled near the strain reliefs for "Maintained" and "Sense". 1. Make sure power is off at the main circuit breaker. 2.
If the firmware is not up to date, upgrade it using ETC Concert and ETC UpdaterAtor software before commissioning is completed. For more information on UpdaterAtor, download the UpdaterAtor Software Quick Guide for free at etcconnect.com.
Page 24
DMX System Control • ArcSystem is compliant with DMX 512-A (ANSI E1.11-2008 (R2013)). • DMX loss behavior is hold last look. For wired DMX installation, each luminaire can be addressed to any one of the 512 DMX addresses up to the maximum device limit of 32 devices on each DMX line. RDM Values Manufacturer ID: 0x6574 (Electronic Theatre Controls) Model IDs...
Page 25
Parameter RDM PID Value Notes DMX Start Address 0x00F0 Range = 001 to 512 Default is 001. Default is 2.This parameter doesn't affect DMX Personality 0x00E0 1 or 2 D1 and D2 Series Drivers. Set to 1 causes output(s) and LEDs of the 0 for stop identify, 1 for start Identify Device 0x1000...
être remplacées seulement par un technicien qualifié. Contactez le service client ETC pour obtenir de l’assistance. WARNING: Disconnect the fixture from power and DMX and allow it to cool before performing any cleaning and maintenance.
Page 27
32 device loads per daisy chain. This product is not self-terminating. You must terminate the last driver on the daisy chain with a 120 Ω resistor. To purchase an RJ45 terminator, please contact your ETC customer service representative and request part number N4086.