VNB Troubleshooting
Content of failure
Fluid leakage
Leakage from the P2 port
Operation failure
External leakage
Others
The shaded
Detailed failure content
Leakage from the valve seal
Others
Shaft seal leakage
Others
Insufficient pilot air
pressure
Increase in the sliding
resistance
Failure of the pilot valve
Others
O-ring failure
External force exists
Others
- 8 -
indicates the case of the solenoid valve type.
Entrainment of foreign matter
to the valve seal
Swelling and breakage of the
valve seal
Tearing of the valve seal
Deformation of the valve seal
Entrainment of foreign matter
to the shaft seal
Swelling and breakage of the
shaft seal
Wearing of the shaft seal
Setting pressure failure
Entrainment of foreign matter/
wearing
Voltage error
Air leakage due to entrainment
of foreign matter to the pilot
valve
O-ring getting caught or
forced out
External force to the pilot
valve
Possible causes
1
2
3
4
5
6
7
8
9
10
11
12
13
14