Download Print this page
Eastron SDM630MCT-RJV-333mV User Manual

Eastron SDM630MCT-RJV-333mV User Manual

Three phase multifunction din rail energy meter, plug-in solution; labor saving; wiring mistake free

Advertisement

Quick Links

EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1
SDM630MCT-RJV-333mV
SDM630MCT-RJA-100mA
Three phase multifunction din rail energy meter
Plug-in solution; labor saving; wiring mistake free
Measures kWh KVarh, KW, Kvar, KVA, P,
F, PF, Hz, dmd, V, A, THD,etc.
Bi-directional measurement IMP & EXP
Plug-in RJ-12 CT connection
Two pulse outputs
RS485 Modbus RTU
Din rail mounting 35mm
Better than Class 1 / B accuracy
Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China.
Tel: 0086-573-83698881/83698882 Fax: 0086-573-83698883 Web: www.eastron.com.cn
USER MANUAL
2016 V1.1

Advertisement

loading

Summary of Contents for Eastron SDM630MCT-RJV-333mV

  • Page 1 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 SDM630MCT-RJV-333mV SDM630MCT-RJA-100mA Three phase multifunction din rail energy meter Plug-in solution; labor saving; wiring mistake free  Measures kWh KVarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, THD,etc.  Bi-directional measurement IMP & EXP ...
  • Page 2 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 1.1 Introduction This document provides operating, maintenance and installation instructions. The unit measures and displays the characteristics of three phase four wires supplies, including voltage, frequency, current, power, active and reactive energy, imported or exported. Energy is measured in terms of kWh, kVarh.
  • Page 3 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 1.5Pulse output This provides two pulse outputs that clock up measured active and reactive energy. The Pulse output 1 is configurable. The pulse output 2 is fixed for the active energy, constant is 3200imp/kWh.
  • Page 4 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 Select the Power display screens In Set-up Mode, this is the “Down” button Select the Energy display screens In Set-up mode, this is the “Enter” or “Right” button Voltage and Current Each successive pressing of the...
  • Page 5 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 Frequency and Power factor and Demand Each successive pressing of the button selects a new range: Frequency and Power Factor (total) Power Factor of each phase Maximum Power Demand Maximum Current Demand Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China.
  • Page 6 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 Power Each successive pressing of the button select a new range: Instantaneous Active Power in kW Instantaneous Reactive Power in kVar Instantaneous Volt-amps in KVA Total kW, kVarh, kVA Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China.
  • Page 7 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 Energy Measurements Each successive pressing of the button selects a new range: Imported active energy in kWh Exported active energy in kWh Imported reactive energy in kVarh Exported reactive energy in kVarh Total active energy in kWh Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China.
  • Page 8 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 Total reactive energy in kVarh Setting Up To enter set-up mode, pressing the button for 3 seconds, until the password screen appears. Setting up is password-protected so you must enter the correct password (default ‘1000’) before processing.
  • Page 9 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 does not roll over between bottom and top of list 2) Press to confirm your selection 3) If an item flashes, then it can be adjusted by the buttons . If not, there may be a further layer.
  • Page 10 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 Press the button to enter the change password routine. The new password screen will appear with the first digit flashing to set the first digit and press to confirm your selection. The next digit will flash.
  • Page 11 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 DIT Demand Integration Time This sets the period in minutes over which the current and power readings are integrated for maximum demand measurement. The options are: off, 5, 8, 10, 15, 20, 30, 60 minutes From the set-up menu, use buttons to select the DIT option.
  • Page 12 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 Backlit set-up The meter provides a function to set the blue backlit lasting time. The backlit lasting time is settable Default lasting time is 60minutes For example, if it’s set as 5, the backlit will be off in 5minutes from the last time operation on the meter.
  • Page 13 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 CT (For SDM630MCT-RJA only) The CT option sets the Primary current (CT1) of the current transformer (CT) that wires to the meter. From the Set-up menu, use buttons to select the CT option.
  • Page 14 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 For example, if set the ratio to be 100,it means the primary voltage equals secondary voltagex100 Pulse output This option allows you to configure the pulse output. The output can be set to provide a pulse for a defined amount of energy active or reactive.
  • Page 15 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 Pulse rate Use this to set the energy represented by each pulse. Rate can be set to 1 pulse per 0.01kWh/0.1kWh/1kWh/10kWh/100/1000kWh. (It shows 1 impulse = 10kWh/kVarh) From the Set-up menu, use buttons to select the Pulse Rate option.
  • Page 16 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 From the Set-up menu, use buttons to select the Pulse width option. Press to enter the selection routine. The current setting will flash. buttons to choose pulse width. On completion of the entry procedure, press to confirm the setting and press to return to the main set up menu.
  • Page 17 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 buttons to choose the first Address(001 to 247) On completion of the entry procedure, press button to confirm the setting and press button to return the main set-up menu. Baud Rate From the Set-up menu, use buttons to select the Baud Rate option.
  • Page 18 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 Parity From the Set-up menu, use buttons to select the Parity option. Press to enter the selection routine. The current setting will flash. buttons to choose Parity (EVEN / ODD/ NONE) Default is NONE.
  • Page 19 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 Press to enter the selection routine. The current setting will flash. buttons to choose Stop Bit (2 or 1) On completion of the entry procedure, press to confirm the setting and press to return to the main set up menu.
  • Page 20 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 Reverse connected current inputs correction set-up buttons to select page “SET sys cont” Press to enter Phase A , the default is Frd (forward) buttons to Phase B or C setting pages How to operate if phase A is reversely connected...
  • Page 21 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 Specifications Measured Parameters The unit can monitor and display the following parameters of a single phase two wire (1p2w), three phase three wire (3p3w) or four phase four wire supply. Voltage and Current Phase to neutral voltages 100 to 289V a.c.
  • Page 22 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1  Reactive power (VAr) ±1% of range maximum  Apparent power (VA) ±1% of range maximum  Active energy (Wh) Class 1 IEC 62053-21  Reactive energy (VARh) ±1% of range maximum ...
  • Page 23 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1  Auxiliary supply voltage Nominal ±1%  Auxiliary supply frequency Nominal ±1%  Auxiliary supply waveform (if AC) Sinusoidal (distortion factor < 0· 05)  Magnetic field of external origin Terrestrial flux Environment ...
  • Page 24 EASTRON SDM630MCT-RJV / SDM630MCT-RJA User Manual V1.1 Installation 3 Phase 4 Wire for SDM630MCT-RJV 3 Phase 4 Wire for SDM630MCT-RJA Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China. - 23 - Tel: 0086-573-83698881/83698882 Fax: 0086-573-83698883 Web: www.eastron.com.cn...

This manual is also suitable for:

Sdm630mct-rja-100ma