Annex to lECEx Certificate of Conformity
Certificate No:
I lECEx ETL 18.0017X
Issue No. I
Annex No. I
Technical Documents
Title:
Drawing No.:
Rev. Level:
Date:
lECEx Technical File
68432
A
11/12/19
Required
Manufacturer
Routine
Testing
Test Title/Description of Test
Standard and Clause
Completed equipment shall be subjected to a routine dielectric strength test.
Test procedures are as follows:
Voltage:
500 Vrms
Duration:
60s
Permitted leakage current:
5mA
IEC 60079-15 Clause 23.2.1
Alternatively, the equipment can be subjected to the following parameters.
Voltage:
600Vrms
Duration:
0.1s
Permitted leakage current:
5mA
The manufacturer is required to record and maintain all results obtained.
Certificate issued by:
Pane I of 1
lntertek Testing Services NA,
SFT-IECEx-OP-1
9f
(26 October
2018)
ntertek
3933 US Route II; Cortland, NY,
13045; USA
Total Quality. Assured.