Download Print this page

Saxby Lighting Seran 78607 Instruction Leaflet

Mw wall

Advertisement

Quick Links

Microwave Movement Sensor
This product is fitted with a microwave movement sensor. Please see below detailed operating instructions.
Technical Specifications:
Operating voltage
220 ~ 240V AC 50/60Hz
Rated load
400W (Capacitive load) 800W (Resistive load)
≤0.5W
Stand-by power
Ceiling mounted
100% / 75% / 50% / 25% / 10%
height: 3m
Sensitivity
Ceiling mounted
100% / 75% / 50%
height: 6m
*
Wall mounted
100% / 75% / 50% / 25% / 10%
height: 2m
Hold-time
5s / 30s / 90s / 3min / 20min / 30min
Daylight sensor
2Lux / 10Lux / 25Lux / 50Lux / Disable
Microwave frequency
5.8 GHz ±75MHz
Transmitting power
1mW Max.
Ceiling mounted
3- 6m (radius )
Detection range
height: 3m
Wall mounted
12-15m
height: 1.5-2m
Detection angle
360
0
(Ceiling) / 120
0
(Wall)
Working temperature
-20
0
C ~ 60
0
C
*
50%, 75%, 100% detection sensitivity is workable when installed at 6m mounting height. Only 10%, 25%
tion signal.
sensitivity is not able to detect mo
Settings:
1. Sensitivity
2. Hold-time
1 2 3
I –100%
I – 5s
100%
II – 75%
II – 30s
III – 50%
75%
III – 90s
IV – 3min
IV – 25%
50%
V – 20min
V – 10%
25%
VI – 30min
10%
Trouble shooting:
Malfunction Cause Remedy
Incorrect light-control setting selected
The light will not come on
Faulty lamp
No power supply
The lamp is always on
Continuous movement in the detection zone
The sensor is not mounted for reliably
detecting movement
The lamp is on without any
identifiable movement
Movement occurred, but not identified by the
sensor (Movement behind wall, movement of
small object in immediate lamp vicinity etc.)
Rapid movements are being suppressed to
The lamp will not work
minimize malfunctioning or the detection
despite movement
radius is too small.
Care and Safety
• We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.
• For your safety, always switch off the power supply before cleaning.
www.saxbylighting.com
3. Daylight sensor
4 5 6
7 8 9
I – 2Lux
5s
II – 10Lux
30s
III – 25Lux
IV – 50Lux
90s
V – Disable
3min
20min
30min
*Disable means the daylight sensor does not work. The sensor will turn
on light once motion is detected regardless of ambient light level.
Cause
Remedy
Adjust daylight threshold setting
Replace lamp
Check power to sensor
Check detection area setting
Securely mount enclosure
1. Reduce sensitivity.
2. Check the movement behind
walls to avoid facilities such as
water pipe, fan, which may
mis-trigger the sensor.
Check detection area setting
Saxby Lighting. BH17 7BY
Instruction leaflet
Seran MW Wall
78607, 78608, 78609, 78610
2Lux
10Lux
25Lux
50Lux
Disable*
V4 16/06/2021
78607
78608
78609
78610

Advertisement

loading
Need help?

Need help?

Do you have a question about the Seran 78607 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Saxby Lighting Seran 78607

  • Page 1 • We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish. • For your safety, always switch off the power supply before cleaning. V4 16/06/2021 www.saxbylighting.com Saxby Lighting. BH17 7BY...
  • Page 2 Installation Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory operation of this product. Please retain these instructions for future reference. Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully note the position of each set of wires.

This manual is also suitable for:

Seran 78608Seran 78609Seran 78610