Positioning of a cooker:
1. Remove the cooker drawer (fig. 5) and then, through the opening, adjust the foot height as needed
with a flat screwdriver.
2. Get the cooker out of plumb position (fig. 6) to get access to the feet from beneath. The regulation
can be done manually with the 8mm allen key. Put the allen key into the feet's hexagonal opening
and turn in the appropriate direction.
Fig. 5

2 PREPARING FOR USE

1. Clean enamel and glass surfaces with a soft, moist cloth.
2. Clean oven, wire shelf, baking trays and the like with the use of hot solution of washing liquid.
3. Before using the appliance for the very first time, we recommend heating particular cooking zones for
about 3 minutes. In this case, as an exception - without putting dishes on them.
4. Operate the oven at the highest temperature for about 1 hour. Any smoke and odour occurring is
harmless, if the kitchen is well ventilated, e.g. by opening the window. After cooling the oven should be
cleaned and dried.

3 INSTALLATION

3.1 ELECTRICAL CONNECTIONS

Cooker is not equipped with the AC power cable. Cooker shall be properly connected to mains by
qualified electrician. No modifications or changes to electric system of the cooker are allowed.
The terminal strip is located on the cooker rear wall and has six screwed cable clamps, including three
phase clamps identified with symbols L1 – L2 – L3, and two neutral terminals identified with symbols
N – N (fig. 7), which should be shorted. The short-circuiting switches, three items, are enclosed with the
terminal strip. The protective earthing terminal is marked with the symbol
INSTALLATION
When placing the cooker in series with kitchen furniture the
distance between the cooker lateral walls and the cupboards
cannot be less than 30mm (fig. 4)
There shall be empty space above the appliance for kitchen
vapours to scatter. In case of installing a kitchen hood the
distance between the ceramic hob and the hood shall be at
least 650mm
Kitchen master switch or the socket where the cooker is
plugged should be freely available for users.
Fig. 4
The cooker is equipped with adjustable feet which serve to
level uneven floor surfaces and to correspond to your work
surface. The regulation should be done by applying one of the
methods below: