R-410A
AFFINITY™ SERIES
DNZ024-060
2-5 Ton
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Location. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Rigging And Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Ductwork . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Roof Curb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Condensate Drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Service Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Power And Control Wiring. . . . . . . . . . . . . . . . . . . . . . . . . 10
Compressors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1 Unit Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 Weights and Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . 6
3 Unit Accessory Weights . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4 Unit Dimensions Front . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5 Unit Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
7 Single Stage Physical Data . . . . . . . . . . . . . . . . . . . . . . . 13
8 Two Stage Physical Data . . . . . . . . . . . . . . . . . . . . . . . . 14
9 Natural Gas Pipe Sizing Chart . . . . . . . . . . . . . . . . . . . . 16
10 Propane (LP) Gas Pipe Sizing Chart . . . . . . . . . . . . . . . 16
1 Component Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 Unit 4 Point Load Weight . . . . . . . . . . . . . . . . . . . . . . . . . 6
3 Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4 Dimensions Front and Bottom . . . . . . . . . . . . . . . . . . . . . 8
5 Dimensions Back and Bottom . . . . . . . . . . . . . . . . . . . . . 8
6 Roof Curb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Thermostat-Single Stage Gas Heat . . . . . . . . . . . . . . . . 11
Thermostat-Two Stage Gas Heat . . . . . . . . . . . . . . . . . 11
Thermostat-Two Stage Gas Heat . . . . . . . . . . . . . . . . . 12

General

®
YORK
Affinity Model DNZ units are cooling/heating air
conditioners designed for outdoor installation. Only gas piping,
electric power and duct connections are required at the point of
installation.
The single or two stage gas-fired heaters have spark to pilot
ignition. The tubular heat exchangers are aluminized steel.
The refrigerant system is fully charged with R-410A Refrigerant,
and is tested and factory sealed.

TABLE OF CONTENTS.

Phasing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Gas Heat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Flue Vent Hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Airflow Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Heating Sequence Of Operation . . . . . . . . . . . . . . . . . . . . 21
Cooling Sequence Of Operations . . . . . . . . . . . . . . . . . . . 23
Start-Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Adjustment of Temperature Rise. . . . . . . . . . . . . . . . . . . . 26
Checking Gas Heat Input . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Natural Gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Typical Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
LIST OF TABLES
15 Side Duct Application . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
16 Bottom Duct Application . . . . . . . . . . . . . . . . . . . . . . . . . 19
17 Additional Static Resistance . . . . . . . . . . . . . . . . . . . . . . 20
18 Indoor Blower Specifications . . . . . . . . . . . . . . . . . . . . . . 21
19 Ignition Control Board FLASH CODES . . . . . . . . . . . . . . 23
20 Gas Rate Cubic Feet Per Hour . . . . . . . . . . . . . . . . . . . . 26
LIST OF FIGURES
10 Typical Field Power Wiring Diagram . . . . . . . . . . . . . . . 12
12 Flue Vent Outlet Air Hood . . . . . . . . . . . . . . . . . . . . . . . 17
13 Single Stage Gas Valve Front . . . . . . . . . . . . . . . . . . . . 24
14 Two Stage Gas Valve Front . . . . . . . . . . . . . . . . . . . . . . 24
15 Single Stage Gas Valve Rear . . . . . . . . . . . . . . . . . . . . 24
16 Two Stage Gas Valve Rear . . . . . . . . . . . . . . . . . . . . . . 25
17 Proper Flame Adjustment . . . . . . . . . . . . . . . . . . . . . . . 25
18 R-410A Quick Reference Guide . . . . . . . . . . . . . . . . . . . 33
Safety Considerations
This is a safety alert symbol
labels or in manuals, be alert to the potential for personal injury.
Understand and pay particular attention to the signal words
DANGER, WARNING or CAUTION.
DANGER indicates an imminently hazardous situation, which,
if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation, which,
if not avoided, could result in death or serious injury.
CAUTION indicates a potentially hazardous situation, which, if
not avoided may result in minor or moderate injury. It is also
used to alert against unsafe practices and hazards involving
only property damage.
. When you see this symbol on
508258-YIM-E-0412

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AFFINITY DNZ060 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for York AFFINITY DNZ060

  • Page 1: Table Of Contents

    This is a safety alert symbol . When you see this symbol on ® YORK Affinity Model DNZ units are cooling/heating air labels or in manuals, be alert to the potential for personal injury. conditioners designed for outdoor installation. Only gas piping,...
  • Page 2 WHAT TO DO IF YOU SMELL GAS: Renewal Parts a. Do not try to light any appliance. ® Contact your local York parts distribution center for authorized b. Do not touch any electrical switch; do not use any replacement parts.
  • Page 3: Installation

    508258-YIM-E-0412 For installation on combustible material and may be installed directly on combustible flooring or, in the U.S., on wood flooring or Class A, Class B or Class C roof covering materials. Improper installation may create a condition where the For use with natural gas (convertible to LP with kit).
  • Page 4: Unit Limitations

    508258-YIM-E-0412 In Canada: If components are to be added to a unit to meet local codes, they are to be installed at the dealer’s and/or customer’s Canadian Electrical Code, CSA C22.1 expense. Installation Codes, CSA - B149.1. Size of unit for proposed installation should be based on heat Local plumbing and waste water codes, and loss/heat gain calculation made according to the methods of Air Other applicable local codes.
  • Page 5: Location

    If a unit is to be installed on a roof curb other than a ® York roof curb, gasketing must be applied to all Excessive exposure of this furnace to contaminated surfaces that come in contact with the unit underside.
  • Page 6: Weights And Dimensions

    508258-YIM-E-0412 "D" CENTER OF FRONT GRAVITY UNIT "A" "C" 49-1/8 "B" 47-1/4 Figure 2: Unit 4 Point Load Weight Table 2: Weights and Dimensions Weight (lbs.) Center of Gravity 4 Point Load Location (lbs.) Size (Tons) Shipping Operating 23.8 (2.0) (2.5) (3.0) 22.7...
  • Page 7: Unit Dimensions Front

    508258-YIM-E-0412 VENT AIR OUTLET HOOD BLOWER SERVICE ACCESS GAS SUPPLY CONDENSER COIL COMPARTMENT PANEL 1-1/4" DIAMETER HOLE (1/2" NPTF CONNECTION) UNIT CONDENSATE CONNECTION 3/4" NPTF (TRAP RECOMMENDED) 2-3/8 HIGH VOLTAGE CONN. 1-3/8" DIA. 3-3/4 KNOCKOUT REFRIGERANT CONNECTIONS 2-1/2 COMBUSTION AIR GAS SUPPLY INLET LOUVERS 1-1/4"...
  • Page 8: Dimensions Front And Bottom

    508258-YIM-E-0412 19-1/4 11-7/8 HIGH VOLTAGE 8-7/8 CONN. 1-3/32" FRONT DIA. KNOCKOUT GAS SUPPLY 1-5/8" DIA. KNOCKOUT (1/2" NPTF CONNECTION) LOW VOLTAGE CONN. 7/8" DIA. KNOCKOUT 4-5/8 CONDENSATE DRAIN 3/4" NPTF 26-3/4 Figure 4: Dimensions Front and Bottom SIDE SUPPLY 14-1/2 AIR OPENING *CONDENSER 28-3/8...
  • Page 9: Ductwork

    508258-YIM-E-0412 RECOMMENDED DUCT SIZE 17-1/2" x 16-3/4" 42-2/3 45-1/8 40-3/4 17-5/8 17-1/4 43-1/4 OPENING FOR 3-1/2 RETURN AIR DUCT OPENING FOR SUPPLY AIR DUCT RECOMMENDED DUCT SIZE 17-1/8" x 21-1/2" Figure 6: Roof Curb Ductwork Refer to Figures 4 and 5 for information concerning rear and bottom supply and return air duct openings.
  • Page 10: Condensate Drain

    508258-YIM-E-0412 Condensate Drain A condensate trap is recommended to be installed in the condensate drain. The plumbing must conform to local codes. Wear safety glasses and gloves when handling Use a sealing compound on male pipe threads. Install the refrigerants. Failure to follow this warning can cause condensate drain line (3/4”...
  • Page 11: Typical Field Control Wiring Diagram Single Stage Thermostat-Single Stage Gas Heat

    508258-YIM-E-0412 NOTE: HEAT ANTICIPATOR SHOULD BE SET AT 0.35 CFM CONTROL BOARD AMPS FOR ALL MODELS. THERMOSTAT TERMINAL STRIP ** = Minimum wire size of 18 AWG wire should be used for all field installed 24 volt wire. 24 VOLT TRANSFORMER PROGRAMMABLE THERMOSTAT ONLY...
  • Page 12: Electrical Data

    508258-YIM-E-0412 NOTE: HEAT ANTICIPATOR SHOULD BE SET AT 0.35 CFM CONTROL BOARD AMPS FOR ALL MODELS. THERMOSTAT TERMINAL STRIP ** = Minimum wire size of 18 AWG wire should be used for all field installed 24 volt wire. 24 VOLT TRANSFORMER PROGRAMMABLE THERMOSTAT ONLY...
  • Page 13: Single Stage Physical Data

    508258-YIM-E-0412 Table 7: Single Stage Physical Data Models Component DNZ024 DNZ030 DNZ036 DNZ042 DNZ048 DNZ060 Nominal Tonnage AHRI COOLING PERFORMANCE Gross Capacity @ AHRI A point 24.7 30.8 35.6 43.0 50.0 59.5 (Btu) AHRI net capacity (Btu) 24.0 30.0 34.2 41.5 48.0 57.5...
  • Page 14: Two Stage Physical Data

    508258-YIM-E-0412 Table 8: Two Stage Physical Data Models Component DNZ024 DNZ030 DNZ036 DNZ042 DNZ048 DNZ060 Nominal Tonnage AHRI COOLING PERFORMANCE Gross Capacity @ AHRI A point 24.7 30.8 35.6 43.0 50.0 59.5 (Btu) AHRI net capacity (Btu) 24.0 30.0 34.2 41.5 48.0 57.5...
  • Page 15: Compressors

    508258-YIM-E-0412 Compressors Phasing The scroll compressor used in this product is specifically Three-phase, scroll compressors operate in only one direction. designed to operate with R-410A Refrigerant and cannot be If the scroll is drawing low amperage, has similar suction and interchanged.
  • Page 16: Natural Gas Pipe Sizing Chart

    508258-YIM-E-0412 AUTOMATIC GAS VALVE If flexible stainless steel tubing is allowed by the 1/2” x 1/2” UNION authority having jurisdiction, wrought iron or steel pipe must be installed at the gas valve and extend a /2” x 1/2” GAS COCK minimum of two (2) inches outside of the unit casing.
  • Page 17: Natural Gas Application Data-Single Stage

    508258-YIM-E-0412 attached to the inside of the gas control/electrical compartment, see Figure 12. The flue exhaust hood must be properly installed and within the recommended clearances. Further communications and action must be given to the Flue hood surfaces may be hot. home or building owner(s) to eliminate any unauthorized human contact around this area during the heating cycle.
  • Page 18: Propane (Lp) Gas Application Data-Single Stage

    508258-YIM-E-0412 Table 13: Propane (LP) Gas Application Data-Single Stage Temp. Rise ºF Input Output Gas Rate Available On Models Number of Burners At Full Input (Mbh) (Mbh) /Hr. Min. Max. 2, 2-1/2, 3 Ton 2, 2-1/2 Ton 3 Ton 3-1/2, 4, 5 Ton 3 Ton 3-1/2 Ton 4, 5 Ton...
  • Page 19: Airflow Performance

    508258-YIM-E-0412 Airflow Performance Table 15: Side Duct Application External Static Pressure (Inch Water Gauge) Size Unit Speed (Tons) SCFM SCFM SCFM SCFM SCFM Low (1) Low/Medium (2) Medium (3) 1037 1116 (2.0) Medium/High (4) 1075 1146 High (5) 1104 1162 Low (1) Low/Medium (2) 1067...
  • Page 20: Additional Static Resistance

    508258-YIM-E-0412 Table 17: Additional Static Resistance Size Wet Indoor Coil Economizer Filter/Frame Kit Electric Heat (Tons) 0.01 0.00 0.01 0.01 0.00 0.02 0.01 0.00 0.04 0.02 0.01 0.06 (2.0) 0.03 0.01 0.08 1000 0.04 0.01 0.10 1100 0.05 0.01 0.13 1200 0.06 0.02...
  • Page 21: Operation

    508258-YIM-E-0412 the spark when flame is sensed and enters a flame stabilization Table 18: Indoor Blower Specifications period. Size Motor If flame is not established within the ignition trial period, the (Tons) Eff. Frame control de-energizes the spark and gas valve and begins an Variable (2.0) inter-purge period before attempting another ignition trial.
  • Page 22 508258-YIM-E-0412 Rollout Switch High Heat If the W2 terminal was energized more than 1 second before If the rollout switch opens for more than 0.25 seconds, the W1 at the start of the call for heat, and remains continuously control board will run the inducer (on high speed for 2 stage energized through the call for heat, the control considers it to be models) for a post-purge period, immediately de-energize the connected to a single stage thermostat and implements a 10...
  • Page 23: Cooling Sequence Of Operations

    508258-YIM-E-0412 of the unit wiring diagram. It resets automatically. The limit condenser coil or a condenser motor failure (opens at 625 switch operates when a high temperature condition caused ± 25 psig and resets at 500 ± 25 psig). by inadequate supply air flow occurs, thus shutting down Low Pressure Switch (LP)- This switch protects against the ignition control and closing the main gas valve and loss of refrigerant charge (opens at 7 ±...
  • Page 24: Single Stage Gas Valve Front

    508258-YIM-E-0412 Remove the access panel. Manual Turn the gas valve switch to the OFF position. Gas Switch Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow B in the information on the unit safety label.
  • Page 25: Two Stage Gas Valve Rear

    508258-YIM-E-0412 Pilot Instruction To adjust the pilot flame: " min. ½ (Inlet) Line Pressure Figure 16: Two Stage Gas Valve Rear Adjust as follows: Spark Ignitor Remove the cap from the valve body. See Figures 13 and 14 for location. Pilot Flame Sensor Figure 17: Proper Flame Adjustment...
  • Page 26: Adjustment Of Temperature Rise

    508258-YIM-E-0412 Adjustment of Temperature Rise NOTE: To find the BTU input, multiply the number of cubic feet of gas consumed per hour by the BTU content of the gas After about 20 minutes of high heat operation, determine the in your particular locality. (Contact your gas company for furnace temperature rise.
  • Page 27: Typical Wiring Diagrams

    508258-YIM-E-0412 Typical Wiring Diagrams Typical DNZ024-060 Cooling Unit with Single Stage Gas Heat 208/230-1-60 volt Wiring Diagram Johnson Controls Unitary Products...
  • Page 28 508258-YIM-E-0412 Typical DNZ024-060 Cooling Unit with Two Stage Gas Heat 208/230-1-60 volt Wiring Diagram Johnson Controls Unitary Products...
  • Page 29 508258-YIM-E-0412 Typical DNZ030-060 Cooling Unit with Single Stage Gas Heat 208/230-3-60 volt Wiring Diagram Johnson Controls Unitary Products...
  • Page 30 508258-YIM-E-0412 Typical DNZ030-060 Cooling Unit with Single Stage Gas Heat 460-3-60 volt Wiring Diagram Johnson Controls Unitary Products...
  • Page 31: 410A Quick Reference Guide

    508258-YIM-E-0412 R-410A QUICK REFERENCE GUIDE Refer to Installation Instructions for specific installation requirements. R-410A efrigerant operates at 50 - 70 percent higher pressures than R-22. Be sure that servicing equipment and replacement components are designed to operate with R-410A. R-410A efrigerant cylinders are rose colored. Recovery cylinder service pressure rating must be 400 psig, DOT 4BA400, or DOT BW400.
  • Page 32 Subject to change without notice. Printed in U.S.A. 508258-YIM-E-0412 Copyright © 2012 by Johnson Controls, Inc. All rights reserved. Supersedes: 508258-YIM-D-0911 York International Corporation 5005 York Drive Norman, OK 73069...

Table of Contents

Save PDF