Page 1
Classic™ i2450 Wood Fireplace Insert Owners & Installation Manual www.regency-fire.com French Manual: https://bit.ly/3bzeO4T Manuel en Français : https://bit.ly/3bzeO4T MODEL: i2450CSA Tested & listed by: Installer: Please complete the details on the back cover and leave this manual with the homeowner.
Page 2
Model Regency i2450 1.4 g /hr 0.07 g/MJ (output). “This manual describes the installation and operation of the Regency i2450 wood heater. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 14,200 Btu/hr. to 34,660 Btu/hr.” Efficiency is determined using the B415 method resulting in lower and higher heat values.
You should always wear appropriate protective gloves to protect your hands from the heat being emitted from this fireplace. ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS. Regency i2450...
Safety Label for i2450 This is a copy of the label that accompanies your Regency Insert. We have printed a copy of the contents here for your review. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
Width: 25" (635 mm) Depth: 17" (432 mm) Two faceplates are available to seal the fireplace opening: Standard W 40" (1 016 mm) x H 30" (762 mm) Oversize W 48" (1 219 mm) x H 33" (838 mm) Regency i2450...
R of 0.893. Since proposed system R is greater han required, the system is acceptable. DEFINITIONS Thermal Conductance: C = Btu = W (hr)(ft2 )(oF) (m2))(K) Thermal Conductivity: k = (Btu)(inch) = W = Btu (hr)(ft3)(oF) (m)(K) (hr)(ft)(oF) Thermal Resistance: R = (ft2)(hr)(oF) = (m2)(K)Btu Regency i2450...
WARNING: The room heater shall not be Electrical code, CSA C22.1. air quality or nuisance conditions. installed in a factory-built fireplace. Regency Inserts are designed to use either a Before Installing 5.5" (140mm) or 6" (152mm) flue. Your Insert ULC628-2022 - Canada This fireplace insert must be installed with 1.
(2 per side) as shown in the diagrams. View from Rear of Insert Note: The grill has a front and rear, the holes on the front side have rounded edges and the rear holes have flat edges. Regency i2450...
WARNING: Operation of the unit with out proper installation of smoke deflector will void warranty. Ensure deflector is seated so bolts are situated at the top of the keyhole before tightening. 10 | Regency i2450...
1) Slide the spring nuts (supplied) over the slots in the insert’s side convection panels (the spring nuts 7) The faceplate trim may be installed to the edge of may need to be squeezed with a pair of pliers first, the faceplate at this time. T o permanently mount the to help them stay in position). trim, drill two 5/32" diameter holes through the trim and side panels and screw the trim to the panels 2) Screw the side faceplate panels, (item A in the using the gold plated screws provided. diagram) one to each side. See diagram 1. Note: I t may be easier to install the insulation, faceplate top and faceplate trim with the unit pulled slightly away from the fireplace face. If this is done, be very careful not to disturb the connector when shifting the unit to its final position. 8) Now that your insert is installed, check once more that all the clearances from the unit to any combus- tible materials are correct as listed earlier. Regency i2450...
Diagram 3. Ensure that the unit is centered in the existing fireplace and lined up with the flue adaptor. Front View 6. Manoeuver the baffle above the air tube and slide out. Diagram 3 Side View 12 | Regency i2450...
Page 13
14. Use the two bolts, washers and lock washers removed in step 7 and install them, tighten down using the 1/2" socket to ensure the adapter is installed. Diagram 6 15. Reverse steps 6-3 to complete the installa- tion. Regency i2450...
1. Align the fan support with the offset clip operation. on the bottom of the ashlip. 4. Push the Regency logo plate into the two holes in the front bottom left corner of the 2. Slide the supports into the clips. The tension fan.
Step 1) Please check to ensure that your floor protection Your Regency stove is supplied with 5 mm Neoceram above. Then reposition the left baffle flat on and hearth will meet the standards for clearance ceramic glass that will withstand the highest heat the air tubes.
(Refer to Diagram 1) Door hinges Wood handle Door Door handle Hinge Cap Cover Diagram 2 tooltip Note: Freestanding stove shown. Door as- sembly instructions are no different for the insert models. Diagram 3 16 | Regency i2450 919-967a 04.03.19...
Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" b) Firebox Floor - install brick over LyTherm Sheet c) Right and Left Side Firebricks 75) * Brick Partial: 1-1/4 x 4-1/2" x 2" 76) * Brick Partial: 1-1/4" x 2" x 9" Regency i2450...
Two dry pieces banged together sound hollow; wet pieces sound solid and dull. • Dry wood weighs much less than wet wood. • Split a piece of wood. If the exposed surface feels damp, the wood is too wet to burn. 18 | Regency i2450...
This may result in damage Both the primary and air wash drafts are controlled your Regency Stove causing a draft down your to your paint finish. by the control slide located on the front left side of chimney.
1. Do not allow ashes to build up to the loading 7. Your Regency stove can be very hot. You may be doors! Only remove ashes when the fire has seriously burned if you touch the stove while it is died down.
Glass Maintenance CAUTION: Things to remember in case of a chimney fire: Your Regency stove is supplied with 5mm Neoceram ceramic glass (Part #846-308) that will withstand 1. Close all draft and damper controls. the highest heat that your unit will produce. In the event that you break your glass by impact, purchase 2.
FOR SUCH INSTALLATION. fumes. Burning coal, cardboard, or loose paper can produce soot, or large flakes of char or fly ash, causing smoke spillage into the room. Cleaning & Maintaining Your Wood Stove 22 | Regency i2450...
2. Loosen the two 7/16'' bolts + nuts to remove / replace vertical deflector. 3. Repeat steps to install new vertical deflector. NOTE: ENSURE THAT VERTICAL DEFLECTOR IS PUSHED UP AS FAR AS POSSIBLE. TIGHT TO TOP OF FIREBOX. Note that the unit is not exactly as shown. Regency i2450...
Allow it to set, then tap or vibrate the screw or bolt to help loosen it before attempting to remove it. For best results, follow the instructions that are provided with the penetrating oil. 24 | Regency i2450...
Black Trim Oversize (set of 3) 295) * Trim Right Oversize 296) * Trim Top Oversize 297) * Trim Left Oversize 298) * Faceplate Side Oversize 299) * Faceplate Top Oversize *Not available as a replacement part. OVERSIZE REGULAR 26 | Regency i2450...
Brick Panels - i2450 Part # Description 180-960 Firebrick - Complete Set 70) 902-111 Brick Regular Full Size: 1-1/4" x 4-1/2" x 9" 75) * Brick Partial: 1-1/4 x 4-1/2" x 2" 76) * Brick Partial: 1-1/4" x 2" x 9" Regency i2450...
Page 28
FPI. Alternatively, FPI may, at its own discretion, fully discharge all of its obligations under warranty by refunding the verified purchase price of the product to the original purchaser. The purchase price must be confirmed by the original Bill of Sale. 28 | Regency i2450...
Page 29
God, weather-related problems from hurricanes, tornados, earthquakes, floods, lightning strikes/bolts or acts of terrorism or war, which result in a malfunction of the Appliance are not covered under the terms of this Limited Lifetime Warranty. Regency i2450...
Page 30
Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-...
Page 31
Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
Page 33
By recycling your used appliances, you divert waste from your local landfills and help the environment. You also reduce the need for raw materials to manufacture new products. Contact your local municipality for appliance recycling services, local recycling programs, or appliance removal services to ensure your Regency appliance components, and packaging are properly recycled. Regency i2450...
Need help?
Do you have a question about the Classic i2450 and is the answer not in the manual?
Questions and answers