5.
Replace the desired Filter Cartridge with a
new one, adjusting it into the Water Machine
until it is securely seated. Then turn the new
Filter Cartridge clockwise to lock into place.
6.
Return the Water Machine to its associated
spot underneath the sink. Slowly open the Di-
verter Valve and plug back in the power cord.
The Water Machine will initiate a Flush Cycle
through the drain for approximately 30 sec-
onds.
7.
Check for leaks surrounding the Water Ma-
chine to ensure a proper filter replacement. If
there are leaks, repeat steps 1-6.
8.
Now that the selected Filter is physically
replaced, manually reset the Filter lifetime on
the Water Machine by using the Select Button
to choose the filter that has been replaced.
Press and hold the Reset Button and the Wa-
ter Machine until there is a chime, signifying
the selected Filter has reset.
17
Need help?
Do you have a question about the WATER MACHINE and is the answer not in the manual?
Questions and answers
Inserted new filter, machine leaves, can't get filter out to start over.
To remove a stuck filter from an UltraLux Water Machine, unscrew the filter from the top of the machine and lift it out. If it is stuck, ensure the machine is on the edge of a cupboard or in a position where you can easily access and apply enough force. Use caution and pull straight to avoid damage.
This answer is automatically generated
After installing the machine and plugging it in, the initial automatic flush is taking longer than 30 seconds. It was still running at the 3 minute mark. I unplugged it. There are no leaks.
The initial automatic flush of the UltraLux WATER MACHINE should only take approximately 30 seconds. If it is taking longer than 3 minutes, the most likely cause is a problem such as low source water pressure, poor water quality, or a clogged filter, all of which can slow the flow rate and extend the flush time.
This answer is automatically generated
do you change both filters at the same time
No. The carbon composite filter (CBPA) should be replaced every 1 year or after 2000 gallons, while the RO membrane filter (ROCB) should be replaced every 2 years or after 1000 gallons.
This answer is automatically generated
When does the hydrogen light indicator comes on? During flush must the H indicator come on?