  • Page 1 General User/ Safety Guide HAMPTON II ACTIVE REPLACEMENT www.harvesthealthcare.co.uk E sales@harvesthealthcare.co.uk www.harvesthealthcare.co.uk...
  • Page 2 T +44 (0)1709 377172 F +44 (0)1709 377173...
  • Page 3: Table Of Contents

    CONTENTS WARNINGS & CAUTIONS WARNINGS & CAUTIONS GENERAL INFORMATION GENERAL INFORMATION 6-10 DEFINITION OF THE GROUPS MENTIONED DEFINITION OF THE GROUPS MENTIONED NON-COMPLIANT USE NON-COMPLIANT USE SAFETY INSTRUCTIONS SAFETY INSTRUCTIONS GENERAL SAFETY INSTRUCTIONS GENERAL SAFETY INSTRUCTIONS SAFETY INFORMATION FOR THE OPERATOR SAFETY INFORMATION FOR THE OPERATOR SAFETY INFORMATION FOR THE USER SAFETY INFORMATION FOR THE USER...
  • Page 4: Warnings & Cautions

    WARNINGS & CAUTIONS READ THIS INSTRUCTION MANUAL AND OBSERVE SAFETY INSTRUCTIONS. WARNING • This system must be properly installed and operated as directed by this user manual. • The system should be checked regularly to ensure correct operation. Loss of function will remove all pressure relieving properties that this system provides.
  • Page 5 WARNINGS & CAUTIONS • Do not expose the pump to liquids. • Do not use with hot water bottles or electric blankets. • Do not allow sharp objects to puncture the mattress material. • The mattress and pump should be cleaned between patient uses. Wipe up any fluid or debris before wiping down with clean, cold water.
  • Page 6: General Information

    GENERAL INFORMATION BEFORE USING THIS SYSTEM FOR THE FIRST TIME: Read through this Instruction Manual conscientiously from start to finish. Please note that the various safety instructions must be observed. Harvest Healthcare products bear the CE mark and meet all safety and functionality requirements.
  • Page 7: Non-Compliant Use

    GENERAL INFORMATION USER / CARE PERSONNEL Users are persons who as a result of their vocational training, experience or briefing are authorised to operate the equipment. Furthermore, the user/ care personnel can recognise and avoid potential dangers and assess the clinical condition of the service user. PATIENT / OCCUPANT / SERVICE USER The person in need of care, handicapped or infirm who is at risk of a pressure ulcer.
  • Page 8: Safety Information For The Operator

    GENERAL INFORMATION The mains cable must be free and not be allowed to be caught up in the bed’s moving mechanisms. The mains cable may be torn out of its strain relief and damaged or it may be pulled out of its socket and electric leads exposed as a result.
  • Page 9: Symbols Used

    GENERAL INFORMATION SYMBOLS USED This symbol indicates general hazards. There is a danger to life and health. Conformity mark in accordance with Medical Device Regulation 2017/745/EU. The symbol for Protection Class II device, double insulated. The symbol for type B device according to EN 60601-1. Handle with care This way up Keep dry...
  • Page 10: Cleaning & Disinfection

    GENERAL INFORMATION CLEANING & DISINFECTION Do not immerse electrical components in water but wipe with a damp cloth only. The electrical components must not be cleaned with a high-pressure cleaner or water jet. Disinfection by wiping only is allowed. Full cleaning and disinfection instructions can be found on pages 14-15. SERVICING &...
  • Page 11: Technical Specification

    TECHNICAL SPECIFICATION HAMPTON II TECHNICAL SPECIFICATION HAMHAMP001 Product Code Pressure Sore Risk Level Very High Risk Maximum Patient Weight: Harvest 1 Pump 25 Stone / 158 kg 29 Stone / 184 kg Harvest 2 Pump Harvest Pump 250 31 Stone / 200 kg Harvest 3 Pump 40 Stone / 254 kg 2000 x 900 x 200 mm...
  • Page 12: Overview

    OVERVIEW SYSTEM OVERVIEW The mattress can be rapidly deflated through the use of a twist valve CPR, allowing emergency personnel to begin resuscitation. Mattress Cover The cover comprises of a two-way vapour-permeable and a stitched stretch PU top with a durable base fabric.
  • Page 13: Installation

    INSTALLATION INSTALLING THE HAMPTON II SYSTEM Remove the mattress from its packaging and lay the parts out on the floor. You should have the following items: • System Packaging • Mattress with feed tubes attached • Instruction booklet If you intend to keep this mattress system in storage at some point please retain the packaging.
  • Page 14: Cleaning & Care

    CLEANING & CARE WARNING Ensure that the mains power supply to the pump is disconnected before cleaning Eye protection, gloves and protective clothing should be worn when carrying out cleaning and disinfection procedures. When disinfecting the system, Harvest Healthcare recommends the following guidelines which have been developed to comply with recognised infection control procedures.
  • Page 15 CLEANING & CARE PUMPS Wipe down with a clean cloth moistened with a mild detergent and dilute with warm water. Rinse by wiping with a cloth with clean water to remove detergent residue. If there are blood spillages or bodily fluids present wipe surfaces down with 0.1% Chlorine solution (1,000 ppm) and wipe down with a clean cloth with clean water.
  • Page 16: Routine Maintenance

    ROUTINE MAINTENANCE These checks should be carried out at each decontamination process, i.e. between patients or patient occupancy and weekly for longer term patients. MATTRESS The mattress cover, which is made from waterproof and vapour permeable material, should be kept clean. Take care to avoid puncturing cover with sharp objects whilst performing the maintenance checks: Remove cover and inspect for damage, tears or staining, which could lead to contamination of the internal parts.
  • Page 17 ROUTINE MAINTENANCE In line with the MHRA Medical Device Alert (MDA/2013/019), Harvest Healthcare • advises customers to use pH neutral, high-level disinfectant cleaning products to sanitise reusable medical devices to prevent damage to materials and the degradation of plastic surfaces after prolonged use. •...
  • Page 18: Troubleshooting

    T +44 (0)1709 377172 F +44 (0)1709 377173...
  • Page 19 E sales@harvesthealthcare.co.uk www.harvesthealthcare.co.uk...
  • Page 20 T +44 (0)1709 377172 F +44 (0)1709 377173...
  • Page 21 E sales@harvesthealthcare.co.uk www.harvesthealthcare.co.uk...
  • Page 22: Parts List

    PARTS LIST APPLIED PARTS HAMPHAMP005.P2 Hampton II Mattress (only) HAMPHAMP005.P250 HAMPHAMP005.P3 HAMHAMP005C Hampton II Cover One Way Valve AMUNI010 REPLACEMENT PARTS AMHAMP003 Air Cell for Hampton II HAMHAMP001C.02 Top Cover for Hampton II HAMHAMP001B.02 Bottom Cover for Hampton II AMUNI011 Quick Connector for Balmoral II AMUNI012 Turning CPR for Balmoral II...
  • Page 23: Guarantees & Warranties

    GUARANTEES & WARRANTIES MATTRESS (COVER AND INTERIOR COMPONENTS) All Harvest Healthcare Ltd Mattress are covered by warranty for a period of 3 years from date of purchase. Damage through incorrect use and penetration by sharp instruments will invalidate this warranty. GUARANTEE Harvest Healthcare Ltd guarantees to repair or replace all goods supplied to its customers which are found to be defective whilst still in their applicable warranty period.
  • Page 24 Sheaf House, Bradmarsh Way, Bradmarsh Business Park, Rotherham, S60 1BW T +44 (0)1709 377 172 F +44 (0)1709 377 173 E sales@harvesthealthcare.co.uk www.harvesthealthcare.co.uk Airflo (Xiamen) Medical Co., Ltd. 4F, No.6, East Haijing Road, Haicang, 361026 Xiamen, Fujian, China Emergo Europe B.V Westervoortsedijk 60, 6827 AT Arnhem, Netherlands Emergo Consulting (UK) Limited...