Configuration profinet example
Hide thumbs Also See for SX502 Series:

Advertisement

Quick Links

FAQ – configuration profinet example for series SX502
Safety precautions
Important Information
Safety
Intended use
Mounting and Installation
FAQ - configuration sx502 profinet example
Author: Achim Baumann
Read these operating instructions before starting the unit. They
provide you with important information on the use, safety and
maintenance of the units. This helps you to protect yourself and
prevent damage to the unit.
Information intended to help you to avoid death, bodily harm or
considerable damage to property are highlighted by the waring
Triangle shown here; it is imperative that this information be
properly heeded.
components inside the units are energized with electricity during
operation. For this reason, mounting and maintenance work may
only be performed by professionally-trained personnel while
observing the corresponding safety regulations.
The units do not have a power switch. They are operative as
soon as the operating voltage is applied.
The units are intended for use in industrial environments. They
may only be operated within the limit values stipulated by the
technical data.
When configuring, installing, maintaining and testing the units,
the safety and accident-preventation regulations relevant to use
in each individual case must be comlied with.
Trouble-free, safe operation of the units requires proper
transport, storage, installation, mounting and careful operation
and maintenance of the units.
The attachment options for the units were conceived in such a
way as to ensure safe, reliable mounting.
The user must ensure that the attechment hardware, the unit
carrier and the anchoring at the unit carrier are sufficient to
securely support the unit under the given surrounding conditions.
The units are to be mounted in such a way that they can be
opened up while mounted. Sufficient space for the cables must
be available in the unit near the cable infeed.
Sufficient space is to be kept clear around the units to ensure air
circulation and to prevent the biuld-up of heat resulting from use.
The relevant information must be heeded in the case of units
ventilated by other means.
23.01.2013
Seite 1/13

Advertisement

loading
Need help?

Need help?

Do you have a question about the SX502 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Siebert SX502 Series

  • Page 1 FAQ – configuration profinet example for series SX502 Safety precautions Important Information Read these operating instructions before starting the unit. They provide you with important information on the use, safety and maintenance of the units. This helps you to protect yourself and prevent damage to the unit.
  • Page 2 FAQ – configuration profinet example for series SX502 When the housing fasteners are opened, the front frame of the housing hinges out upward or downward (depending on the unit version) automatically. Grounding All devices are equipped with a metal housing. They comply with safety class I and require a protective earth connection.
  • Page 3 FAQ – configuration profinet example for series SX502 2. Start Siemens Simatic Manager 3. extract the example file from the file folder FAQ - configuration sx502 profinet example 23.01.2013 Seite 3/13 Author: Achim Baumann...
  • Page 4 FAQ – configuration profinet example for series SX502 4. open the hardware configuration FAQ - configuration sx502 profinet example 23.01.2013 Seite 4/13 Author: Achim Baumann...
  • Page 5 FAQ – configuration profinet example for series SX502 5. accolate a name to the slave and close the window FAQ - configuration sx502 profinet example 23.01.2013 Seite 5/13 Author: Achim Baumann...
  • Page 6 FAQ – configuration profinet example for series SX502 6. choose a configuration from hardware catalog and set it on the plug-in position of the profinet slave (for example RT EIN 001 byte and RT AUS 008 bytes) Attention! Please remember the definition of data bytes out (in this example is 8 Bytes) If you choose another configuration (for example 16 Bytes) you must set this value in FC3 at the hardware settings but in HEX.
  • Page 7 FAQ – configuration profinet example for series SX502 7. change the E/A Address of the profinet slave configuration Attention! Please remember the definition of E/A addresses. If you choose another definition (for example E-address 4 and A-address 10) you must set this value in FC3 at the hardware settings but in HEX.
  • Page 8 FAQ – configuration profinet example for series SX502 8. save and translate hardware configuration and send it to the plc. FAQ - configuration sx502 profinet example 23.01.2013 Seite 8/13 Author: Achim Baumann...
  • Page 9 FAQ – configuration profinet example for series SX502 9. open FC3 („SX502 Communication“) and scroll down until displayed „set H E R E datas of hardware configuration“ change there the values that is set in the hardware configuration Attention! Values must be enter in HEX. In hardware configuration the values are in DEC. OutputAddr = 32 HEX (in hardware configuration 50 DEC) InputAddr = 2 HEX (in hardware configuration 2 DEC) LenConsData = 8 HEX (in hardware configuration 8 DEC)
  • Page 10 FAQ – configuration profinet example for series SX502 10. also in FC3 you set the marker bytes for choose the DB that will send if you control this marker byte Marker byte DB no. to send FAQ - configuration sx502 profinet example 23.01.2013 Seite 10/13 Author: Achim Baumann...
  • Page 11 FAQ – configuration profinet example for series SX502 11. save everything to the plc FAQ - configuration sx502 profinet example 23.01.2013 Seite 11/13 Author: Achim Baumann...
  • Page 12 12. open the variables sheet 13. control the marker byte with keys „CTRL + 1“ Now on the display of the SX502 will be text : „Welcome to Siebert Industrieelektronik GmbH“ This is the text in DB3. If you control M0.1 the text that display called: „Innovation in display“...
  • Page 13 FAQ – configuration profinet example for series SX502 14. If you want to send an individual text change only the text in DB3 and control the marker byte M0.0 In FC3 you can expand the function with the control of marker bytes if you have more text you would send.

This manual is also suitable for:

Sx602 series