Siebert SX302 Series Operating Instructions Manual

Siebert SX302 Series Operating Instructions Manual

Alphanumeric large size displays with profinet io rt interface

Advertisement

Quick Links

Serie SX302
Alphanumeric large size displays
with PROFINET IO RT interface
Operating instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SX302 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Siebert SX302 Series

  • Page 1 Serie SX302 Alphanumeric large size displays with PROFINET IO RT interface Operating instructions...
  • Page 2: Table Of Contents

    Table of contents 1 Contact 2 Legal note 3 Safety precautions Important information ............................5 Safety ................................. 5 Intended use ............................... 5 Mounting and installation ............................ 5 Grounding ................................5 EMC measures ..............................6 Disposal ................................6 4 Model designation Model designation ..............................
  • Page 3: Contact

    Contact www.siebert-group.com GERMANY Siebert Industrieelektronik GmbH Siebertstrasse, D-66571 Eppelborn P.O. Box 11 30, D-66565 Eppelborn Phone +49 (0)6806 980-0, Fax +49 (0)6806 980-999 email: info.de@siebert-group.com AUSTRIA Siebert Österreich GmbH Simmeringer Hauptstrasse 24, A-1110 Wien Phone +43 (0)1 890 63 86-0, Fax +43 (0)1 890 63 86-99 email: info.at@siebert-group.com...
  • Page 4: Legal Note

    Siebert , LRD and XC-Board are registered trademarks of Siebert Industrieelektronik GmbH. All other product names mentioned herein may be trademarks or registered trademarks of their respective owners. We reserve the right to make alterations to the technical data and delivery options without notice. - All rights reserved, including the rights of translation.
  • Page 5: Safety Precautions

    Safety precautions Important information Read these operating instructions before starting the unit. They provide you with important information on the use, safety and maintenance of the units. This helps you to protect yourself and prevent damage to the unit. Information intended to help you to avoid death, bodily harm or considerable damage to property is highlighted by the warning triangle shown here;...
  • Page 6: Emc Measures

    EMC measures The devices comply with the current EU Directive (EMC Directive) and provide the required interference immunity. Observe the following when connecting the operating voltage and data cables: Use shielded data cables. The data and operating voltage cables must be laid separately. They may not be laid together with heavy-current cables or other interference-producing cables.
  • Page 7: Model Designation

    Model designation Model designation This manual applies to units with the following model designation (x = the 'x's in the model designation indicate the size and design of the units): SX302-xx/xx/xx-xxx/xx-N0 Unit construction The following figure shows model type SX302-06/10/xx-xxx/xx-xx as example for the other model types.
  • Page 8: Quick Start

    Step 3: Install the GSDML file of the ad and add the display Install the GSDML file of the display. You find the file on the supplied data carrier or at www.siebert- group.com. After installation, the display is listed in the hardware catalog.
  • Page 9: Step 4: Establish A Connection To The Display

    Step 4: Establish a connection to the display Assign the display to the desired control in the network view. Then the PROFINET connection is shown. Step 5: Add sub-module to the display and define address range Add the module 'Simplified page module' from the hardware catalog to the device overview. This specifies that the display expects the values to be shown in ASCII String format.
  • Page 10: Step 6: Assign A Profinet Device Name To The Display

    Now assign the IP address and device name to the display. To do this, call up the context menu of the Siebert display in the Device view and click on 'Assign device name'. After the data is transferred successfully to the display, the configuration is displayed as follows in the engineering tool.
  • Page 11: Step 7: Define Text

    To send a value to the display, you can for example create a function chart with 'MOVE' instructions. In the following screenshot the text 'Siebert' is sent. This requires two 'MOVE' function blocks. Spep 8: Loading hardware configuration and program into the control.
  • Page 12: Technical Data

    Technische Technical data Fieldbus Interface PROFINET IO RT, conformance class CC-B MAC address The MAC address for the PROFINET coupling is on the top side of the device. Integrated switch PROFINET IO IRT, conformance class CC-C Power supply The screw terminals for the power supply are located on the power supply unit in the lower part of the housing.

Table of Contents