Page 1
IOM-WQ-CWS-150 Installation, Operation and Maintenance 11/2" Commercial Water Softener Systems Series: CWS-150 & CWSTA-150 CWS-150 Simplex Systems CWSTA-150 Duplex Alternating Systems...
Page 2
Congratulations on your purchase of this Watts commercial water softening solution. ® You have made a great choice to protect your plumbing system against the damaging effects of hard water. This system has been engineered for trouble free operation and produced using top quality components. Simple programming, corrosion resistant mineral tank(s) and an easy to service design ensures this system will be durable and easy to maintain.
Exposure to such hydrocarbons may cause the products to leak. Do not use the product(s) contained in this document on If you are unsure about installing your Watts water softener water supplies that contain hydrocarbons such as kerosene, contact a Watts representative or consult a professional water benzene, gasoline, etc.
when operated within the manufacturer’s operational guidelines. System Specifications Dimensions - Weights Dimensions - Weights CWS-150 CWSTA-150 A & B A & B SIDE FRONT FRONT SIDE Series CWS-150 MODEL NO. DIMENSIONS WEIGHTS M4410W 1353 1353 1550 1016 1734 1734 1869 1016 M4414W...
Page 7
Ordering Information Ordering Information for 1-1/2" Simplex (CWS-150) and Duplex Alternating (CWSTA-150) Softeners SPACE REQUIRED WEIGHT MODEL NO. ORDERING CODES DESCRIPTION D X W X H M4410W 68105557 2 Cubic Foot 1-1/2" Simplex Softener with Flow Meter 24" x 44" x 75" M4414W 68105558 3 Cubic Foot 1-1/2"...
Hardness (maximum) ... Depends on customer’s series number. If any components are missing or damaged acceptable hardness contact your Watts representative. If they can not be reached leakage level contact Watts customer service at 1-800-659-8400.
4h. Press the upper diffuser into the base of the control valve compound formulated for potable water O-ring applica- tions. Watts recommends Ordering Code #68102757 Silicone until it is fully engaged, then place the control valve on top of Lubricant. The use of other types of lubricants may attack the tank.
8*. Install an inlet water sample port in the supply line and close it. 19. Plug in the 15V power supply transformer(s) into a 115V 9*. If risk of vacuum exists, install Watts # 0556031 vacuum 60Hz power outlet and program the system according to...
MATERIAL: DECIMAL in[mm] ±1/32 ±1° TECHNOLOGIES, INC AND MAY NOT BE USED OR DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF WATTS .XX[0.X] ±.25[6.35] EDP NO.: DECIMAL in[mm] THIS DRAWING DISCLOSES CONFIDENTIAL AND OTHER DATA OF A PROPRIETARY NATURE OWNED BY WATTS WATER .XXX[0.XX] ±.125[3.175]...
Page 12
THIS DRAWING D TECHNOLOGIES, INC DWG BY: CHD BY: Installation Diagrams - CWSTA-150 Duplex Alternating Systems CWSTA-150 TWIN ALT Top View MINERAL TANK MINERAL TANK POLY TUBING BRINE TANK POLY TUBING BRINE TANK TOP VIEW TOP VIEW INLET UNION ISOLATION VALVE 1.5"...
Front Cover and Drive Assembly Drawing No. Order No. Description Quantity V3175EE-01 WS1EE FRONT COVER ASSEMBLY Controller Electrical Connections V3107-01 WS1 MOTOR V3002-A WS1 DRIVE BRACKET ASY Electrical Connections: V3408EE-04BOARD WS1THRU/2 EE PCB 5 DIGIT REPL NOTICE V3110 WS1 DRIVE GEAR 12X36 Power supply and drive motor cables include cable harnesses that are already connected to the control board.
“REGEN Pndg RINSE FILL” is displayed whenever a zero-capacity tank has transferred to an off-line state and is currently waiting to initiate the second portion of a regeneration cycle. Viewed only when Delayed Rinse and Fill is set to ON. Controller Programming and Operation Button Operation and Function Button Operation and Function...
Controller Programming and Operation Page 6 EE Man u al User Displays User Displays When the system operating, one of five displays may be shown. Pressing NEXT will General Operation When the system is operating, one of ve displays may be shown. Pressing NEXT will General Operation alternate between the displays shown below.
Page 16
Controller Programming and Operation EE Man u al EE Man u al Page 7 Page 7 Configuration Settings Con guration Settings Con guration Settings Step 1CS – Press NEXT and ▼ simultaneously for 5 seconds and release. Press NEXT and ▼ Step 1CS –...
Selection requires that a connection to a Watts Motorized Alternator Valve (MAV) is made to the two pin connector labeled MAV located on the When set to SEPS the MAV will be driven closed before the rst regeneration cycle, and be driven open printed circuit board.
Page 18
WS1, WS1.25 and WS1.5 Valves For Watts twin alternator systems using CWS-150 valves there will be an option to delay the last two cycles by tank just prior to returning to service. Set to oFF to deactivate this feature. With 1.0T set, the same For Clack Corporation alternator systems using WS1, WS1.25 and WS1.5 valves there will be an option to...
Page 19
Selection requires that a connection to a Clack No Hard Water Bypass (V3070FF or V3070FM) be made Selection requires that a connection to a Watts No Hard Water Bypass (V3097/ BSPT or V3098/ BSPT) to the two-pin connector labeled MAV located on the printed circuit board for WS1 and WS1.25 control be made to the two-pin connector labeled MAV located on the printed circuit board for CWS-150 valves.
Controller Programming and Operation EE Man u al Page 11 OEM Softener System Setup OEM Softener System Setup Step 1S - Press NEXT and ▼ simultaneously for 5 seconds and release. If screen in Step 2S does not Step 1S Step 1S –...
Page 21
Page 12 EE Man u al Controller Programming and Operation Step 9S – Select the pounds for the fth cycle using ▲ or ▼. For valve types 1.5 and 2.0, “oFF” is also Step 9S Step 9S – Select the pounds for the fifth cycle using or .
Page 22
Controller Programming and Operation EE Man u al Page 13 Step 15S – Set Relay Actuation Time or Gallons using or . The choices are: Step 15S – Set Relay Actuation Time or Gallons using ▲ or ▼. The choices are: Step 15S •...
Controller Programming and Operation Setting Options Table Volume Capacity Regeneration Time Option Day Override Result Reserve capacity automatically estimated. AUTO Normal Regeneration occurs when volume capacity falls below the reserve capacity at the next Regen Set Time. Reserve capacity automatically estimated AUTO Normal Any number...
Controller Programming and Operation EE Man u al Page 17 Installer Display Settings - Regeneration Type Auto Installer Display Settings - Regeneration Type Auto Step 1I – To enter Installer Display press NEXT and simultaneously for about 5 seconds Step 1I - To enter Installer Display press NEXT and ▲ simultaneously for about 5 seconds and release. Step 1I and release.
Controller Programming and Operation EE Man u al Page 19 Installer Display Settings - 7 Day Regeneration Installer Display Settings - 7 Day Regeneration Step 1I - To enter Installer Display press NEXT and ▲ simultaneously for about 5 seconds and release. Step 1I Step 1I –...
Controller Programming and Operation Page 20 EE Man u al Diagnostics Diagnostics Step 1D - Press ▲ and ▼ simultaneously for 5 seconds and release. If screen in Step 2D does not appear Step 1D – Press simultaneously for 5 seconds and release. If screen in Step 2D does not appear Step 1D the lock on the valve is activated.
Page 27
Controller Programming and Operation Page 21 EE Man u al Step 9D – Volume, reserve capacity used for last 7 days: If the valve Step 9D – Volume, reserve capacity used for last 7 days: If the valve is Step 9D is set up as a softener, a meter is installed, and Set Volume Capacity set up as a softener, a meter is installed, and Set Volume Capacity is set is set to “Auto,”...
Replacing the Media 15. Continue to siphon resin until it is completely evacuated from NOTICE the mineral tank. Gravel will clogged the siphon hose and, if Ion exchange resin may need to be replaced periodically it must be removed due to fouling, or to repair or replace a due to physical breakdown caused by chlorine/chloramine damaged distributor tube and screen, must be evacuated by disinfectants, or fouling caused by certain metals such as...
Troubleshooting WS1.5", 2" and 2"QC Drawings and Service Manual Page 17 Troubleshooting Procedures Problem Possible Cause Solution a. No power at electric outlet a. Repair outlet or use working outlet b. Control valve Power Adapter not plugged into b. Plug Power Adapter into outlet or connect outlet or power cord end not connected to PC power cord end to PC Board connection board connection...
Page 35
Troubleshooting Page 18 WS1.5", 2" and 2"QC Drawings and Service Manual Problem Possible Cause Solution a. Bypass valve is open or faulty a. Fully close bypass valve or replace b. Media is exhausted due to high water usage b. Check program settings or diagnostics for abnormal water usage c.
Page 36
Troubleshooting- Controller Error Codes Page 19 WS1.5", 2" and 2"QC Drawings and Service Manual Problem Possible Cause Solution a. Motor not inserted full to engage pinion, motor a. Disconnect power, make sure motor is wires broken or disconnected fully engaged, check for broken wires, make sure two pin connector on motor is connected to the two pin connection on the PC Board labeled MOTOR.
Page 37
Troubleshooting- Controller Error Codes Page 20 WS1.5", 2" and 2"QC Drawings and Service Manual Problem Possible Cause Solution a. Control valve programmed for ALT A or b, a. Press NEXT and REGEN buttons for 3 nHbP, SEPS, or AUX MAV with out having a seconds to resynchronize software with MAV or NHBP valve attached to operate that piston position or disconnect power supply...
Water Softener Flow Diagrams WS1.5", 2" and 2"QC Drawings and Service Manual Page 21 WS1.5 Control Valve Cycle Positions CWS-150 SERVICE Raw water inlet Treated water supply BACKWASH Raw water inlet Backwash water to drain Raw/hard water is bypassed during regeneraion...
Page 39
Water Softener Flow Diagrams Page 22 WS1.5", 2" and 2"QC Drawings and Service Manual WS1.5 Control Valve Cycle Positions CWS-150 DOWNFLOW BRINE Raw water inlet Regenerant water to drain Raw/hard water is bypassed during regeneraion Regenerant solution being drawn in Injector feed from raw water inlet UPFLOW BRINE...
Page 40
Water Softener Flow Diagrams WS1.5", 2" and 2"QC Drawings and Service Manual Page 23 WS1.5 Control Valve Cycle Positions CWS-150 RINSE Rinse water to drain Raw water inlet Raw/hard water is bypassed during regeneraion TREATED WATER REFILL Raw water inlet Treated water supply Treated water to regenerant tank...
Injector Flow Data and Draw Rates Page 34 Page 34 WS1.5", 2" and 2"QC Drawings and Service Manual WS1.5", 2" and 2"QC Drawings and Service Manual VIOLET, ORDER NO. V3010-15B VIOLET, ORDER NO. V3010-15B VIOLET, ORDER NO. V3010-15B VIOLET, ORDER NO. V3010-15B VIOLET, ORDER NO.
Page 42
WS1.5", 2" and 2"QC Drawings and Service Manual WS1.5", 2" and 2"QC Drawings and Service Manual Page 35 Page 35 Injector Flow Data and Draw Rates WS1.5", 2" and 2"QC Drawings and Service Manual Page 35 WHITE, ORDER NO. V3010-15D WHITE, ORDER NO.
Page 43
Injector Flow Data and Draw Rates Page 36 Page 36 WS1.5", 2" and 2"QC Drawings and Service Manual WS1.5", 2" and 2"QC Drawings and Service Manual GREEN, ORDER NO. V3010-15G GREEN, ORDER NO. V3010-15G GREEN, ORDER NO. V3010-15G GREEN, ORDER NO. V3010-15G GREEN, ORDER NO.
Page 42 WS1.5", 2" and 2"QC Drawings and Service Manual Motorized Alternating Valve Piston Style Applications Motorized Alternating Valve Piston Style Applications For V3071, V3071BSPT, V3076 or V3076BSPT OPERATING PRESSURES: 20 PSI MINIMUM / 125 PSI MAXIMUM OPERATING PRESSURES: 20 PSI MINIMUM / 125 PSI MAXIMUM OPERATING TEMPERATURES: 40°F MINIMUM / 110°F MAXIMUM OPERATING TEMPERATURES: 40°F MINIMUM / 110°F MAXIMUM Service or Installation of Motor: Do not lubricate the motor or the gears.
Page 46
Motorized Alternating Valve Piston Style Applications WS1.5", 2" and 2"QC Drawings and Service Manual Page 43 Twin Tank Alternator: Service or Installation of Motor. If the control valve manual does not include instructions for setting up ALTA and ALTb software, please contact your local equipment supplier for current copies of installation instructions.
Page 47
V3264 WS2 BYPASS REDUCTION GEAR AXLE SCREW 1/4-20 X 3/4 BHSCS SS V3527 (5/32” HEX ALLEN WRENCH REQUIRED) Motorized Alternating Valve Piston Style Applications V3072 MAV/NOHWBY 1/125/15 DRIVE ASY V3506-01 MAV/NOHRD 1/125/15 PISTON V3074 MAV 1/125/15 STACK ASY MAV ordering information: V3525-01 MAV BODY 1.5 NPT Order No.
AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL SHIPMENT. USA: T: (800) 659-8400 • N. Andover, MA 01845 • Watts.com Canada: T: (888) 208-8927 • Burlington, ON M5J3G6 • Watts.ca Latin America: T: (52) 55-4122-0138 •...