Laars FT Series User Manual

Laars FT Series User Manual

Floor standing, modulating gas, condensing, combination boiler 199,000 btu/h

Advertisement

User's Manual
FOR YOUR SAFETY: This product must be installed and serviced by a professional service technician,
qualified in hot water boiler and heater installation and maintenance. Improper installation and/or operation
could create carbon monoxide gas in flue gases which could cause serious injury, property damage, or
death. Improper installation and/or operation will void the warranty.
If the information in this manual is not
followed exactly, a fire or explosion may
result causing property damage, personal
injury or loss of life.
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from a
nearby phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed
by a qualified installer, service agency, or gas
supplier.
User's Manual for
Floor Standing, Modulating
Gas, Condensing, Combination Boiler
Model FTCF199N
199,000 BTU/h
WARNING
Natural Gas (NG) - Factory Configuration
Propane - Field-Convertible
AVERTISSEMENT
Assurez-vous de bien suivres les instructions
données dans cette notice pour réduire au
minimum le risque d'incendie ou d'explosion
ou pour éviter tout dommage matériel, toute
blessure ou la mort.
Ne pas entreposer ni utiliser d'essence ni
d'autres vapeurs ou liquides inflammables dans
le voisinage de cet appareil ou de tout autre
appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareils.
• Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones dansle bâtiment où vous êtes.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions
du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le sservice des incendies.
L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié ou
par le fournisseur de gaz.
Document 1506A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FT Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Laars FT Series

  • Page 1 User’s Manual Document 1506A User’s Manual for Floor Standing, Modulating Gas, Condensing, Combination Boiler Model FTCF199N 199,000 BTU/h Natural Gas (NG) - Factory Configuration • • Propane - Field-Convertible FOR YOUR SAFETY: This product must be installed and serviced by a professional service technician, qualified in hot water boiler and heater installation and maintenance.
  • Page 2 Page 2 ........CONTENTS 1. Familiarizing yourself to the floor standing FT Series Combi ..2 2. Caring For Your FT Series Combi ..........2 3. Start Up and Shut Down...............4 4. Control Setup and Operation ............4-10 2 CLASPS CENTRAL HEAT PRESSURE GAUGE...
  • Page 3 User’s Manual - The FT Series Floor Standing, Combination Boiler The FT Series Floor Standing, Combination Boiler Page 7 Page 3 The FT Series Floor Standing, Combination Boiler Page 7 Names of Components Names of Components Name of Component Pressure Relief Valve...
  • Page 4 A complete ‘Setup’ must be Close all manual gas valves. performed by a qualified service person. If freezing is anticipated, drain the FT Series Combi and be sure to also protect building piping from freezing. All water must be removed from heat...
  • Page 5: Lcd Overview

    Page 52 Page 52 User’s Manual - The FT Series Floor Standing, Combination Boiler Page 5 LCD Overview LCD Overview Page 52 LCD Overview LCD Overview Anti-Freeze Storage Lock Communicating Central Anti-Freeze Lock Communicating Storage Central Mode Heating Heat Mode...
  • Page 6: Operating Mode

    Page 6 The FT Series Wall Mounted, Combination Boiler Page 53 Operating Mode Operating Mode After the Power is turned on, and/or the Control Display is turned on , the Control Display 55page will go through a ‘Start Up’ checklist and briefl y show a sequence of diagnostic codes before entering into the ‘Operating Mode.
  • Page 7: Status Display Mode

    User’s Manual - The FT Series Floor Standing, Combination Boiler Page 7 Page 54 56page Status Display Mode Digital Display Status Display Parameter Description O:ot Outdoor temperature Current Outdoor temperature A: Li or A: GA Flow unit Current fl ow value(Li: L/m, GA: GPM)
  • Page 8: Dhw Set Point Change Mode

    Page 8 The FT Series Wall Mounted, Combination Boiler Page 55 57page DHW Set Point Change Mode DHW Set Point Change Modes The display shows the following information when changing water heating temperature set points. Changing between Celsius and Fahrenheit...
  • Page 9: Ch Set Point Change Mode

    User’s Manual - The FT Series Floor Standing, Combination Boiler Page 9 Page 56 58page CH Set Point Change Mode Changing between Celsius and Fahrenheit When the button D is pressed (for more than 5 seconds), temperature unit will toggle between °C and °F.
  • Page 10 Page 10 Notes:...
  • Page 11 User’s Manual - The FT Series Floor Standing, Combination Boiler Page 11 Notes:...
  • Page 12 User’s Manual - The FT Series Floor Standing, Combination Boiler Notes: Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Customer Service and Product Support: 800.900.9276 • Fax 800.559.1583 Industrial Way, Rochester, NH, USA 03867...

This manual is also suitable for:

Ftcf199n

Table of Contents