This product is only suitable for well insulated spaces or occasional use.
To be left with the customer after demonstrating the features of the Solution electric fire.
The complete installation must be carried out by professional personnel in accordance
with current Standards and Local Codes. The instructions in this manual must be
followed to ensure safe operation of the appliance. It should be noted that the
requirements and this publication may be superseded during the life of the Fireplace -
please refer to www.solutionfires.co.uk for up-to-date instructions.
The product complies with the European Safety Standards EN60335-2-30 and the European
Standard Electromagnetic Compatibility (EMC) EN55014, EN60555-2 and EN60555-3. These cover
the essential requirements of EEC Directives 2006/95/EC and 2004/108/EC
July 2024 - V1.4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Solution LUX650 and is the answer not in the manual?

Questions and answers

Summary of Contents for Solution FIres Solution LUX650

  • Page 1 Instruction Manual Solution LUX650 Cassette Fire This product is only suitable for well insulated spaces or occasional use. To be left with the customer after demonstrating the features of the Solution electric fire. The complete installation must be carried out by professional personnel in accordance with current Standards and Local Codes.
  • Page 2: Table Of Contents

    Warranty supervised. Solution Fires App Control Instructions Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its intended normal operating position and they have been given instruction or supervision concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 3: Important Safety Advice

    4. A 220-240 Volt socket or switched, spur capable of accommodating a maximum load of 2050 in this manual, or the Solution Fires app. Do not use this heater with a programmer, timer, watts must be available close to the appliance. The socket must be accessible at all times and separate remote control system or any other device that switches the heater on automatically.
  • Page 4: Installation Instructions

    Installation Instructions Installation Instructions Installation - Wall mounting: Installation - Existing fireplace: This fire has been designed to fit into an existing The fire can be permanently fixed to a wall at a suitable height, the wall bracket must be fitted chimney with adequate space.
  • Page 5: Operating Instructions

    Operating Instructions Remote Control Operation MANUAL CONTROL PANEL FIRE ON/OFF BUTTON MANUAL POWER ON/OFF SWITCH HEATER Power on/off Flame Speed Flame Colour Pre-set Flam Down Light Scn button has no function on this model Fuel Bed Colour Fuel INDICATOR Heat Volume Heat Custom...
  • Page 6: Product Dimensions

    Remote Control Operation Continued Product Dimensions IMPORTANT NOTE: The fan will run for approximately 15 seconds after the heating function is turned off to remove any residual heat from the unit to protect the control components from any potential overheating. Do not press heater ON/OFF button again as this will turn the heat back on. Remote control button combinations: Switch beep off: Activate or deactivate the confirmation beep by pressing and holding ‘Vol’...
  • Page 7: Cleaning

    Cleaning Battery Replacement Information requirements for electric local space heaters Remote Control before cleaning it. 1. Switch off and unplug from the power Model identifier: Insert Solution 650 Battery information - see Fig. 35 supply before cleaning. Item Symbol Value Unit Item Unit...
  • Page 8: Troubleshooting

    3. Fan Heater - just like any fan heater there will be the sound of air being blown into the room. Solution Fires Warranty 4. Sampled Fire Sounds - The Solution LUX650 features a fire audio option. The volume of this sound can be adjusted using your handset or smart device. Excessive noise should be For Warranty information, terms and conditions and to referred to your retailer.
  • Page 9 Please note the handset that was supplied with your fire and the Solution Fires app work independently of each other. As such neither handset will be able to receive feedback from the other.
  • Page 10 4. Open the Solution Fires App. 5. Wait a moment for the Solution Fires App to initiate and then it will ask you to create an account or log in to your existing account. If you have already registered and signed in to your account, your App will proceed to screen 6.
  • Page 11 Solution Fires App will start to search for your Solution LUX Fire. 7. Your Solution Fires App will find the fire you are trying to connect to and show it listed on the App screen. The fire will have a unique factory pre-set name similar to "SLE_LUX_#####".
  • Page 12 ON/OFF SWITCH HEATER INDICATOR 14. Open the Solution Fires Application and follow the instructions from point 5. When you arrive at enjoy the many control features. NOTE: The LED indicator is illuminated red to indicate that power is on, but without Wi-fi connection.
  • Page 13: Naming Fires

    Naming Fires 15. You may want to change the name settings button at the top of the Home screen. here you can rename them all one by-one. Touch the blue “pad and whose name you would like to change. 18. Type new name and then submit.
  • Page 14: Adding Fires

    Adding Fires Home Screen Explained this, touch the settings button at the top of the Home screen. 22-27 To the left are the Home button and the Settings button. To the right are the 7-day timer button and the Instructions button. a.
  • Page 15: Accessing Features Via Settings Menu

    25. Manual heater buttons. Accessing Features a. Press for 1kW of heat or for 2kW of heat. via Settings Menu please see section 28 of these instructions on setting Target Temperature. By activating the (See previous page) heater buttons from the Home screen, you override the Target Temperature feature if it has been set.
  • Page 16: Sound

    7 Day Programmer (See image on previous page) 35. Your app will automatically take the day and time from your phone or tablet. If you are setting Sound your fire up in a different time zone to the one your phone or tablet was set up in, then first select “Date &...
  • Page 17: Account Settings

    40. The Account Settings screen is reached by selecting that button from the Settings menu. 47. Download the Solution Fires Skill onto your smart device you use to control Alexa. In order to use 41. The features here assume that you are logged in to your account...
  • Page 18: Faq Relating To The Solution Fires App

    By touching this you will be sent an e-mail to the e-mail address you you permit this. This information is not stored or used in any way by Solution Fires. Please refer to previously registered and from that e-mail you will be able to reset your password. If a new the Privacy Policy and Terms and Conditions for further information.
  • Page 19 Yes, navigate to the settings page of your app , select “Adding & naming fires”, tap the blue “pen and account to the Solution Fires account you have set up in your app, then try some of the commands listed pad”...
  • Page 21 From time-to-time improvements will be introduced and we would ask that you periodically check the website solutionfires.co.uk for updates to these instructions. www.solutionfires.co.uk info@solutionfires.co.uk CAPITAL FIREPLACES LTD, Unit 12-17 Henlow Trading Estate, Henlow Camp, Bedfordshire, SG16 6DS. UK.

This manual is also suitable for:

Insert solution 650

Table of Contents