Michael Perry
February 9, 2025

When it is full it did not turn off and so water spilled out (and ruined a carpet). Any suggestions please? (Have never used the drainage pipe).

2 comments:
Mr. Anderson
February 11, 2025

To fix the issue of the Shinco SDL5-10D not turning off when full, follow these steps:

1. Check the Water Tank: Ensure the water tank is properly installed. If it is misaligned, the sensor may not detect the full tank correctly.
2. Empty the Tank: Remove and empty the water tank, then reinstall it securely.
3. Inspect the Water Level Switch: The dehumidifier has a water level switch that detects when the tank is full. Check if it is stuck or malfunctioning.
4. Ensure Proper Electrical Connection: If the water level switch is disconnected or faulty, the unit may not recognize a full tank.
5. Reset the Unit: Turn off the dehumidifier, unplug it for a few minutes, then plug it back in and restart.
6. Clean the Sensor: If the sensor is dirty or obstructed, clean it gently to ensure it properly detects the water level.

If the issue persists, professional repair may be required.

This answer is automatically generated

Michael Perry
February 12, 2025

@Mr. Anderson Thank you most kindly for your extensive response. I shall investigate!

Summary of Contents for Shinco SDL5-10D

  • Page 1 Model: SDL5-10D SDL5-12D Dehumidifier Déshumidificateur d'air Luftentfeuchter Deshumidificador Deumidificatore...
  • Page 2 SDL5-10D SDL5-12D Fig1 High Auto Clean Laundry...
  • Page 3 Dear customer, ♦ Repairs must be performed based on the recommenda- Many thanks for choosing to purchase a SHINCO brand product. tion from the manufacturing company. Maintenance and Thanks to its technology, design and operation and the fact that it exceeds the strictest repairs that require the assistance of other qualified per- quality standards, a fully satisfactory use and long product life can be assured.
  • Page 4 ENGLISH (Original instructions) ♦ If any of the enclosures of the appliance breaks, immediately switch off the appliance to Full tank avoid the possibility of electric shock. LED display ♦ Do not use the appliance if it has fallen, if there are visible signs of damage, or if there Humidity control is a leak.
  • Page 5 ENGLISH (Original instructions) ♦ The LED display screen will show the humidity % selected. ONCE THE APPLIANCE HAS BEEN USED: ♦ Stop the appliance by pressing button on/off (8) LAUNDRY FUNCTION: ♦ Unplug the appliance from the mains. ♦ Press the mode button (7) to select this function. The pilot light above indicates the ♦...
  • Page 6 ENGLISH (Original instructions) Problem notifucations Solution Code Normal phenomenon,this function will be activated when the ambient temperature falls Anti-frost function below about 16°C.It will be activated for a period of 8 munites every 38 minutes between 2°C-12°C and 5 minutes every 60 minutes between 12°C-16°C. Empty the water tank according to the instructions above.
  • Page 7 ENGLISH (Original instructions) DETECTION OF FLAMMABLE REFRIGE- RANTS tions. ♦ h) Do not overfill cylinders. (No more than 80 % volume liquid charge). ♦ Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked ♦...
  • Page 8: Maintenance

    Glashütte 1 , Tor/B3 42799 Leichlingen, Germany ♦ Check safety equipment before putting into service. Tel: 0049-21751869828 Sales Support: service@shinco.net Maintenance ♦ Portable equipment shall be repaired outside or in a workshop specially equipped for servicing units with flammable refrigerants.
  • Page 9 ♦ Personen, die am Kältemittelkreis- lauf arbeiten oder Sehr geehrte Kundin diesen betreiben, müssen über eine entsprechende Zer- Wir danken Ihnen für Ihre Entscheidung, ein SHINCO Gerät zu kaufen. tifizierung von einer akkreditier-ten Organisation verfü- Die Technologie, das Design und die Funktionalität dieses Produkts, das die anspruchs- vollsten Qualitätsnormen erfüllt, werden Sie über viele Jahre zufriedenstellen.
  • Page 10 DEUTSCH Übersetzung aus den ursprünglichen anweisungen BESCHREIBUNG ♦ Der Stecker des Geräts muss mit dem Steckdosentyp des Stromanschlusses übere- instimmen. Der Gerätes- tecker darf unter keinen Umständen modifiziert werden. Keine Transportgriff Adapter für den Stecker verwenden. Bedienungspaneel ♦ Nicht mit Gewalt am elektrischen Anschlusskabel ziehen. Benutzen Sie das elektrische Kabel nicht zum Anheben oder Transportieren des Geräts.
  • Page 11 DEUTSCH Übersetzung aus den ursprünglichen anweisungen ♦ Sobald die gewünschte Zeit erreicht ist, drücken Sie die Taste nicht mehr. Nach 5 ♦ Sekunden wird die ausgewählte Zeit bestätigt. Abdeckung ab und nehmen Sie den Deckel heraus. Schließen Sie den Schlauch an ♦...
  • Page 12 DEUTSCH Übersetzung aus den ursprünglichen anweisungen Anomalien Ursache Lösung Das Gerät funktioniert nicht. Fällt der Stecker herunter? Stecken Sie den Stecker in die Steckdose. Ist der Wassertank voll oder schlecht angebracht? Entfernen Sie das Wasser aus dem Tank und bringen Sie ihn erneut an.
  • Page 13 DEUTSCH Übersetzung aus den ursprünglichen anweisungen und die richtige Spezifikation geeignet sein. Die Wartungsund Instanthaltungsrichtli- nicht ausreichend oder erfordert eine Neukalibrierung. (Das Leckerken- nungsgerät nien des Herstellers müssen jederzeit befolgt werden. Wenden Sie sich im Zweifelsfall muss in einem Bereich ohne Kältemittel kalibriert werden). Es muss sichergestellt wer- an die technische Abteilung des Herstellers.
  • Page 14 DEUTSCH Übersetzung aus den ursprünglichen anweisungen ♦ g) Der Rückgewinnungsmotor muss eingeschaltet und gemäß den Anweisungen des der Belüftung des Gehäuses ab. Die Abschaltung des Gerätes oder das Öffnen des Herstellers betrieben werden. Schaltschranks hat einen wesentlichen Einfluss auf die Sicherheit. Es ist darauf zu achten, dass zuvor eine ausreichende Belüftung gewährleistet ist.
  • Page 15 ♦ Die maximale Anzahl der Geräte, die zusammen gelagert werden dürfen, richtet sich nach den örtlichen Vorschriften. KONFORMITÄTSERKLÄRUNG Glashütte 1 , Tor/B3 42799 Leichlingen, Germany Tel: 0049-21751869828 Verkaufsunterstützung:service@shinco.net Dieses Produkt entspricht den folgenden Europäischen Richtlinien: 2014 / 30 / EU (EMC) 2014 / 35 / EU (LVD)

This manual is also suitable for:

Sdl5-12d
Save PDF