Off-grid Hybrid Inverter User Manual Product models: AU4830-EU-60-H | AU4850-EU-80-H | AU4835-US-60-H|AU4850-US-80-H Solar Energy Storage Inverting & Control All-In-One Machine...
Page 2
Important Safety Instruction Please maintain the manual for reference in the future The manual comprises all safety, installation and operation instruction for AU48-H Solar Energy Storage and Inverting Control All-in-one Machine. Before installation and use, please carefully read all instructions and notices in the manual. There is unsafe voltage inside the all-in-one machine.
1. Basic Information 1.1 Product overview and characteristics AU48-H series is a new type of mixed solar energy storage inverting & control all-in-one machine integrating solar energy storage & municipal power charge storage and AC sine wave output. It adopts DSP control and advanced control algorithm to achieve characteristics of high response speed, high reliability and high industrial standard.
13.It has the function of mixed load: when the battery is not connected, photovoltaic and commercial power can supply power to the load at the same time (if there is no battery, the commercial power must be connected). When the battery is full, it can also enter the mixed load mode, which can make full use of the photovoltaic energy.
1.3 Product characteristics Overload protector Dry contact port ⑨ ON/OFF rocker switch Cooling fan ② ⑩ ACi nput port Battery port ③ ⑪ AC output port Cooling fan ④ ⑫ Grounding screw hold PV port ⑤ ⑬ RS485-2 communication port Touch the key lightly ⑥...
1.4Dimension drawing 2. Installation Instruction 2.1 Installation notice Before installation, please carefully read the manual and get familiar with the installation step. Take care while installing the battery. When installing the lead-acid liquid battery, it is required to wear goggles.
PV. Please refer to the table below for PV input wire diameter and switch: Recommended wire Maximum PV input Recommended types of Type diameter current air switchor breaker AU4830-EU-60-H 2P—25A /10AWG AU4850-EU-80-H 2P—25A /10AWG AU4835-US-60-H 2P—25A /10AWG AU4850-US-80-H 2P—25A...
Page 9
Please refer to the table below for recommended AC input wire diameter and switch: Recommended types of Recommended wire Maximum bypass Type diameter input current air switchor breaker AU4830-EU-60-H 2P—40A 10mm /7AWG 10mm /7AWG AU4850-EU-80-H 2P—40A 10mm /7AWG AU4835-US-60-H 2P—40A...
2.3 Installation and Wiring Installation step: Step 1: confirm the installation position and heat dissipation space, confirm the installation position of all-in-one machine, such as wall surface; to install the all-in-one machine, guarantee there is sufficient air flowing through the cooling fins of all-in-one machine. At least reserve 200mm space at the left and right air outlets of the all-in-one machine to guarantee heat loss through natural convection.
Page 11
Step 3: wiring AC input/output wiring method: Before AC input/output wiring, disconnect the external breaker at first and then confirm whether the cable used is thick enough. Please refer to chapter “ 2.2 Wiring Specification and Breaker type”; Correctly connect AC input wire in accordance with cable sequence and terminal position shown in the figure below.
Page 12
②Correctly connect PV input wire in accordance with cable sequence and terminal position shown in the figure below. PV+ positive input pole PV1- negative input pole BAT wiring method: Before wiring, disconnect external breaker at first, and then confirm whether the used cable is thick enough. Please refer to chapter “...
close the breaker or fuse. At the same time, guarantee that “+” and “-” poles of different parts are correctly connected with wires; a breaker must be installed at the battery end and selected based on chapter “2.2 Wiring Specification and Breaker Type”. Before wiring, make sure to break the breaker to prevent strong electric spark generated during wiring.
supply for charge to maintain electric quantity of the battery. It is suitable for areas with relatively stable power grid and relatively expensive electricity price. 2. Mains supply priority: mains supply is to charge the battery preferentially and the photovoltaic charge can be started only when the mains supply is valid.
Page 15
Mains supply priority mode: it only switches to inverter for power supply when mains supply is invalid, equivalent to a backup UPS. Therefore, the mode is applicable to area with unstable power grid. Inverter priority mode: it only switches to mains supply in case of undervoltage of battery. With the mode, ...
4. Operation Instruction for LCD Screen 4.1 Operation and display panel 4.2 Introduction to operation keys Function Key Description Enter/exit setting menu Last option DOWN Next option Confirm/enter option under setting menu 4.3 Introduction to indicator light Indicator light Color Description Constant on: mains supply output AC/INV...
Page 17
4.4 Introduction to LCD screen Icon Function Icon Function Indicating that AC input end Indicating that inverter circuit is in has been connected to working. power grid Indicates that the AC input Indicating that the machine is in mode in APL mode (wide mains supply bypass work mode voltage range) Indicating that PV input end...
Page 18
Indicating that present Indicating that buzzer is not battery type of the machine is enabled lithium battery Indicating that current Indicating alarm of machine battery type of machine is lead-acid battery Indicating that the battery is in Indicating that the machine is in charge state.
Page 19
Real-time data view method In LCD main screen, press keys “UP” and “DOWN” to turn page and view different realtime data of the machine. Middle Page Left Parameter of Screen Parameter of Right Parameter of Screen Screen Battery input voltage Output voltage PV temperature PV output KW...
Page 20
No. of Name of Setting Description Parameter Parameter Option Exit [00] ESC Exit from setting menu At photovoltaic priority mode, when the photovoltaics is invalid or the battery values are [01] SOL lower than the parameter 【04】 setting value, it shall switch to AC power.
Page 21
charge and AC charge can be performed at the same time only when AC bypass is output under load. When inverter works, only photovoltaic charge can be started. [06] OSO Only photovoltaic charge, no AC charge is started. Maximum [07] 60A charge Setting range 0~80A;...
Page 22
No. of Name of Setting Description Parameter Parameter Option So as to overdischarge delay time, when the battery voltage is lower than parameter Overdischarge [13] 5S 【12】, the inverter output is turned off after delay time default delaying the time set with the parameter. 5S~50S setting range at 5S step is valid in case of a self-defined and lithium battery.
Page 23
No. of Name of Setting Description Parameter Parameter Option [22] DIS No energy-saving mode default After enabling the energy-saving mode, in case of Energysaving empty or small load, the output is turned off after mode output delaying of inverter for a certain period of [22] ENA time.
Page 24
(enabled) No. of Name of Setting Description Parameter Parameter Option RS485 RS485 communication address setting range [30] 1 address 1 ~ 254, (refer to Number [32] is valid when default setting set as SLA) Battery [35] 52V lowvoltage Setting range 44V~58.4V default recovery Battery fully...
Battery type parameters For Lead-acid Battery : Battery type Sealed lead Colloidal lead Vented lead User-defined acid battery acid battery acid battery (USE) Parameters (SLD) (GEL) (FLD) Overvoltage disconnection voltage 40~60V Equalizing charge voltage 58.4V 56.8V 59.2V (Adjustable) 40~60V Boost charge voltage 57.6V 56.8V 58.4V...
Page 26
For Lithium Battery : Lithium Lithium Lithium Ternary Ternary Battery type iron iron iron User- lithium lithium phosphate phosphate phosphate defined battery battery Parameters battery battery battery (USE) (N13) (N14) (L16) (L15) (L14) Overvoltage disconnection voltage Equalizing charge 40~60V voltage (Adjustable) 53.2V 57.6V...
5.Other Function 5.1 Dry node function Working principle: this dry node can control the switch of diesel generator to charge the battery. ① Under normal conditions, in this terminal, NC-N point is closed and NO-N point is opened; ② when the battery voltage reaches the low-voltage disconnection voltage point, the coil of the relay is energized and NO-N point is closed and NC-N point opened.
Page 28
6.Protection 6.1 Protection function Protection Note Function Current limiting When the charge current of the configured PV array exceeds the protection rated current of PV, it will be charged at the rated current. At night, because the battery voltage is greater than that of the PV Anti-reverse charge module, the battery shall be protected against discharge through protection at night...
Page 29
AC reverse flowing Prevent AC power inverted from battery inverting against reverse protection flowing into bypass AC input. Bypass overcurrent Built-in AC input overcurrent protection breaker. protection 6.2 Meaning of fault code Affecting Fault Code Fault Name Note output or not 【01】...
Page 30
【26】 RlyShort Inverted AC Output Backfills to Bypass AC Input 【29】 BusVoltLow Bus undervoltage protection 6.3 Some fault troubleshooting Fault Solving Measures Check whether the battery air switch or PV air switch is closed; No display on screen whether the switch is in "on" state; press any key on the screen to exit from the screen sleep mode.
7.System Maintenance In order to maintain the optimum and permanent operation performance, it is suggested to check the following items semiannually. Confirm that the air flow around the all-in-one machine will not be blocked. In addition, remove any dirt or debris from the radiator.
8. Technical Parameter Model AU4830-EU-60-H AU4850-EU-80-H AU4835-US-60-H AU4850-US-80-H AC mode Rated input voltage 220/230Vac 110/120Vac (170Vac~280Vac) ±2% Input voltage range (90Vac-140Vac) (90Vac-280Vac) ±2% Frequency 50Hz/ 60Hz (auto-sensing) 47±0.3Hz ~ 55±0.3Hz (50Hz); Frequency range 57±0.3Hz ~ 65±0.3Hz (60Hz); Overload/short- Breaker circuit protection Efficiency >95%...
Page 33
Efficiency >90% (102%<load<125%) ±10%: reporting error and (102%<load<110%) ±10%: reporting error and turn off the output after 5 minutes; turn off the output after 5 minutes; (125%<load<150%) ±10%: reporting error and (110%<load<125%) ±10%: reporting error and Overload protection turn off the output after 10 seconds; turn off the output after 10 seconds;Load>125% Load>150% ±10%: reporting error and turn off ±10%: reporting error and turn off the output...
Page 34
range Maximum output 4200W 5000W 4200W 5000W power Charge current range of solar 0-60A 0-80A 0-60A 0-80A energy (settable) Charge short-circuit Blown fuse protection Inverse wiring protection Wiring protection Authentication specification Specification CE(IEC62109)、RoHs authentication EMC authentication EN61000 grade Operation -15°C to 55°C temperature range Storage -25°C ~ 60°C...