PIAB P6040 Manual

PIAB P6040 Manual

Function v30, es vacuum, es blow

Advertisement

Quick Links

Manual
Manual
P6040
P6040
Function V30, ES Vacuum, ES Blow
Function V30, ES Vacuum, ES Blow

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P6040 and is the answer not in the manual?

Questions and answers

Summary of Contents for PIAB P6040

  • Page 1 Manual Manual P6040 P6040 Function V30, ES Vacuum, ES Blow Function V30, ES Vacuum, ES Blow...
  • Page 2 This manual is available in the following languages at piab.com Chinese English French German Italian Japanese Korean Polish Portuguese Russian Spanish Swedish Page 2/12 Page 2/12 P6040 V30 Manual...
  • Page 3: Table Of Contents

    2.4 Misuse......6 3. Introduction to P6040 V30 ..6 3.1 Manufacturer.
  • Page 4: Introduction To The Manual

    Note! Information that needs extra attention! 1.1 About the manual P6040 V30 is used in applications where a constant Wear eye protection vacuum pressure is desired. The manual is available for download at piab.com in the 12 languages shown on page 2.
  • Page 5: Safety

    Maintenance must be carried out in accordance with implementation in industrial systems; therefore, it the instructions in this manual. Prior to any must not be used with conditions other than those maintenance work, suspend pneumatic/electrical specified herein. supply, and discharge residual pressure. Page 5/12 P6040 V30 Manual...
  • Page 6: Intended Use

    On/Off and ES • Do not use blow-off functions or ejector exhaust for pressurizing components such as • The P6040 Function Valve V30 is used for On/ cylinders and/or tank-volumes. Off control. • Do not use compressed air pressure or electrical •...
  • Page 7: Connections

    Pin 1, 24 VDC On/Off Electrical connection DIN43650 Pin 2, GND C-8 mm Function ES Blow Connector Pin 1, 24 VDC M8 3-pol, Pin 4, Signal vacuum/ pressure Pin 3, GND switch Figure 3 Pneumatic diagram. Page 7/12 P6040 V30 Manual...
  • Page 8: Technical Data

    Safety classification Current consumption Ripple Power Function ES Blow Unit Value Signal range -kPa 15–100 Hysteresis 1-99 Voltage Safety classification Current consumption Ripple Power Function Spare parts Art no Function V30 0117783 Function ES Vacuum 0117784 Page 8/12 P6040 V30 Manual...
  • Page 9: P6040 Es Programming Steps, Vaccuum/Blow

    P6040 ES programming steps, Vaccuum/Blow 6. P6040 ES programming steps, Vaccuum/Blow Measure mode OUT 1 mode setting Figure 4 Measure mode. Figure 6 OUT 1 mode setting. – Press (Set) button for more than 3 sec. – Use buttons to set Out1 mode.
  • Page 10 P6040 ES programming steps, Vaccuum/Blow Response time setting Measure Mode Figure 8 Response time setting. Figure 10 Measure mode. – Use buttons to set response time. (2.5, 24, 192 and 768 mS.) Set to 192 mS Pressure setting mode (Hysteresis)
  • Page 11: Warranty

    The warranty does not apply to any Product sure that a minimal environmental footprint is used. (including any component or other parts in such Piab is certified against with ISO-14001, and also Products (such as suction cups, filter elements, complies with REACH (EC 1907/2006).
  • Page 12 +33 (0)16-430 82 67 +46 (0)8-630 25 00 +55 (0)11-449 290 50 +86 21 5237 6545 +33 (0)16-430 82 67 +46 (0)8-630 25 00 +55 (0)11-449 290 50 +86 21 5237 6545 info-france@piab.com info-sweden@piab.com info-brasil@piab.com info-china@piab.com info-france@piab.com info-sweden@piab.com info-brasil@piab.com info-china@piab.com Mölndal...

Table of Contents