Redarc SBI12-BLD Manual

Redarc SBI12-BLD Manual

Bms load disconnect isolator
Hide thumbs Also See for SBI12-BLD:

Advertisement

BMS Load Disconnect
Isolator
SBI12-BLD

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SBI12-BLD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Redarc SBI12-BLD

  • Page 1 BMS Load Disconnect Isolator SBI12-BLD...
  • Page 2: Warning And Safety Instructions

    1. Over discharge risk. Ensure that the Turn OFF voltage is suitable for the specications provided by the battery manufacturer. 2. The SBI12-BLD is designed for controlling loads from an Auxiliary battery. Using the SBI12-BLD to isolate from a start battery will result in a state of charge too low to start the vehicle.
  • Page 3: Specifications

    WARNING & SAFETY INSTRUCTIONS 3. The SBI12-BLD will achieve best results when proper battery maintenance is regularly performed. This includes but is not limited to checking water and specic gravity levels of the battery. Refer to the battery manufacturers manual for more details.
  • Page 4 (earth when loads should be on, no earth when loads should be off), and there is additional voltage thresholds monitored by the SBI12-BLD to ensure reliable solenoid engagement. The Isolator monitors the auxiliary battery and when this drops below the Turn OFF voltage, the solenoid will open, disconnecting the load.
  • Page 5: Installation Instructions

    INSTALLATION INSTRUCTIONS 1. Mount the SBI12-BLD securely in a convenient location near the auxiliary battery bank. Do not mount in direct engine heat. 2. Install in the order described below: • Ground Connection. Connect the SBI12-BLD ground terminal to the BMS Load Disconnect terminal.
  • Page 6: Standard Wiring Diagrams

    • Ensure the loads are properly grounded to a Battery Terminal Terminal common chassis earth point. • Ensure the SBI12-BLD ground wire is wired to the load Disconnect terminal of the BMS. LED Output Wire • When using fuses make sure that the fuse (BLUE) makes a good low resistance connection.
  • Page 7: Fault Indication

    FAULT INDICATION NOTE: The LED will be on when the SBI12-BLD is active (on). Should a fault occur, the SBI12-BLD is set to notify the operator of the fault. The LED will ash repeatedly with the following sequences: CODE 1...
  • Page 8: Frequently Asked Questions

    Answer: This can occur for one of two reasons. Firstly, switching an excessively large load which would drop the battery to below its lower voltage limit and causing the SBI12-BLD to turn off. After turning off the load, the battery would recover in voltage; If the battery voltage climbs higher than the turn on threshold, the SBI12-BLD would turn the loads back on.
  • Page 9: Warranty

    Pride Park 87−100 Torun Poland DE24 8HG, Derby Design and specications are subject to change without notice | Copyright © REDARC Electronics Pty Ltd. All rights reserved REDARC®, THE POWER OF REDARC®, and BCDC® are trademarks of REDARC Electronics Pty Ltd.
  • Page 10 Tech Support 1300 REDARC (1300-733-272) Australia +61 8 8322 4848 New Zealand +64 9 222 1024 UK & Europe +44 (0)20 3930 8109 +1 (704) 247-5150 Canada +1 (604) 260-5512 Mexico +52 (558) 526-2898 redarcelectronics.com WARSBI12BLD-4 EN...