Installation Guide - Haier HW-07LF03 Operation Manual

Window type room air conditioner
Table of Contents

Advertisement

Installation Guide

Selection of the installation position
1. The air-conditioner is better installed in shadow or in a place with short
period of sunshine. In case the air-conditioner is installed at the point
exposed directly to the sunshine, it should be protected from the direct
sunlight as possible in order to avoid the long time of direct sunlight
otherwise its performance will be lowered. (As illustrated in Fig. 1).
2. For the convenience of operation, it is recommended that air-conditioner
be installed at least at the height of 760-1300 mm above the floor and no obstacles
before it for a free airflow.
3. The shutters at both sides and the top of air-conditioner should be
protruded outdoors free from being blocked by wall, window, etc.
4. The back of air-conditioner should be kept over 500mm from the
obstacles (for example, wall, etc.) (As illustrated in Fig. 2).
5. To have an efficient drainage, the back part of the air-conditioner should
be inclined downward by 5-10mm (As illustrated in Fig. 3).
cover
support
>500mm
fig.1
fig.2
fig.3
The enclosed accessories of the conditioner are:
Name
Manual
Outlet pipe fitting
Sealed gasket
Drain pan
Screw
Figure
1
1
Quantity
1
1
2
11