Use with Room Thermostat (Optional) ........36 2.6.3. Circulation Pump ................11 3.1.8. Use of Outside Temperature Sensor (Optional) ....36 2.6.4. Монтажные Схемы Котлов Серии Minerwa 25 .....12 3.2. CUSTOMIZING COMBI BOILER FEATURES ......37 2.6.5. Filling the siphon for Condensation Line .........13 2.6.6.
Children must not operate the boiler. authorized WARMHAUS service. Project design and application for LPG use should be performed by the company supplying the tank in accordance with local and legal rules. MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
- Gas Appliances Directive 2009/142/EC - Boiler Efficiency Directive 92/42/EEC WARMHAUS A.Ş. reserves the right to make all kinds of technical and commercial amendments without giving - Low Voltage Directive 2014/35/EU information and rejects all responsibilities depending on - Electromagnetic Compatibility Directive 2014/30/EU misspelling.
WARMHAUS all wall-hung boilers granted Gas categories for WARMHAUS boilers applied on CE certification on SZU Test / BRNO are given bellow; - the appliance category(ies) in relation to the direct countries of destination has been spesified EN 15502-1; GAR Certificate E-30-00300-18 product ID Nr.
2. INSTALLATION PERSONNEL SECTION 2.1. CONTENTS OF PACKING BOX Warmhaus is sold as two boxes with combi and flue set. Combi box contains below listed materials and small box contains exhaust gas flue pipes. I. Installation Scheme (Figure 1) 110 mm II. User’s Guide (Figure 2) III.
2.2. BEFORE INSTALLATION (MINERWA 25 SYSTEM BOILER) 2.2.1. Contents Of The Packaging The Warmhaus boiler is delivered in a box with the following contents 110 mm 201 mm 150.11.606.000076 125 mm 129 mm 379 mm MODE RESET 1. Wall Mounting Template 2.
2.4. BOILER INSTALLATION RULES • Combi boiler should be installed on a wall resistant to fire. 2.4.1. General Rules for Installation Places of • NOTICE: Combustible and corrosive materials: Combi Boilers a) Chemically aggressive substances can corrode the appliance and invalidate any guarantee. No restriction is available for places where Hermetic (C b) Do not store or use any combustible materials typ) combi boiler is installed (devices may be installed...
• The distance between the collector and tube should be maximum 125 cm. • Copper pipe installation should not be used for Figure 7 Minerwa combi boiler dimensions and distances longer than 125 cm. connections MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
Page 10
In case of failing to fulfil these conditions, combi boiler shall not be commissioned by WARMHAUS Authorized Services. Ball Valve COLLECTOR 370 mmH 2 kg...
- If the combi boiler is correctly connected to gas and radiator purposes) both heating and hot water circuits electrical sources; must be insulated. - If the combi boiler is supplied from gas and electricity MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
PRODUCTS • Covers should be used for radiator and hot tap water wall Grundfos Pump Performance test Figure 11 Minerwa 25 and Minerwa System 25 Pump with passages and fixed with wall clamps for preventing slopes Title Test data UPM3 15-70 CAOD AA...
Figure 15 Scheme of use of the boiler in a mobile tubular distributed heating installation system Figure 16 Scheme of use of the boiler in a mobile tubular distributed underfloor heating installation system MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
2.6.5. Filling the siphon for Condensation Line 2.6.6. Discharging the Condensation Water After hanging the boiler on the wall, electrical For discharging the condensation water produced by the connections, radiator lines, hot tap water connections device, it should be connected to waste water grid via and condensation water drainage line are completed, at least Ø...
Page 15
68 mm Ø PVCU 43 mm 90º male/female bend Fitting Outdoor flusher Water / Air proof Min Ø 19 mm MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215 insulation Inner pipe Minimum 30 mm 75 mm flusher Outdoor flusher...
Combi should only be installed with original WARMHAUS air suction and exhaust gas discharge device made of plastic material. Plastic channels cannot be installed without suitable protection against UV and weather conditions to distances over 40 cm and exteriors.
Only ONE 25mm clearance is allowed per installation. If one of the dimensions D, E, F, G or H is 25mm then the remainder MUST be as shown in brackets, in accordance with B.S.5440-1. MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
2.7.3. Installation with Horizontal Flue Sets performed. • Make required flue selection for the flue connection Connecting Horizontal Concentric Flue Set to the Combi to be made external and installation place of the Boiler, (original diameter DN 60/100 mm) combi boiler. If the standard flue set is not adequate, Since your combi boiler is hermetic model, it takes the please select most suitable elements from our list of used air from exterior and discharges exhaust gases...
/ discharge flue should not blocked even Additional Elbow Equivalent To temporarily кратковременный и временный (Ø60/100 mm) Straight Length характер. 45° Degree 0.5 meter 90° Degree 1 meter MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
L1 + L2 +L3 ≤ 9 m (a + b + c+ e + f ≤ L a- Standard Flue Set Elbow (90°) b- Flue Extension Pipe (L1) c- Additional 45° Elbow d- Standard Flue Set Pipe (L2) e- Additional 45° Elbow f- Standard Flue Set Pipe (L3) Figure 32 III.
=1.0 m. (90° elbow equivalent length) =1.5 m. L Total =12 m. 12 m. < Lmax = 30 m. Figure 35 Hermetic flue type installation sample Correct in implementation. MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
Page 22
Design Individual air supply and flue outlet pipes are used as standard. The material approved for this application which MUST be used are: Termination Of The Flue And Air Acceptable Operating Area The flue and air pipes may terminate independently through any external walls within the same dwelling 20 22 24 26 28 30 32 34 36 except on opposing walls, within the maximum lengths...
L = 130 мм 15311660600132 (Claret) Flat Roof Outlet Part Pitched Roof Outlet Tile A = 500 x 500 mm 15311660600124 15311660600125 132,5 mm 500 mm 129 mm MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
2.7.8. Twin Flue Kits For Condensing Boilers (Ø80/Ø80mm) Minerwa 25 and Minerwa System 25 Название / описание изделия Код изделия Ø80 Twin Flue Set 15311660600135 Condensing Split Horizontal Flue Set Minerwa 25 and Minerwa System 25 Ø80 + Ø80 Ø60- Ø80 Twin Flue Set Adapter...
This sensor can be directly connected to electrical installation of the combi boiler, and it automatically reduces the maximum central heating flow temperature in the installation when exterior weather temperature MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
15311660600001 temperature to the boiler. A single boiler heating Temperature system must be used with one Outside Sensor to Sensor save fuel. See Technical Catalogue for more information. MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
ROOM THERMOSTAT G S M OUTSIDE TEMP. SENSOR OPEN THERM 24V AC CONNECTION WHITE ORANGE WHITE OUTSIDE TEMP. WHITE SENSOR ORANGE OPENTHERM ORANGE GREEN GREEN THERMOSTAT BRIDGE GREEN WARNING: REMOVE THE BRIDGE WIRE FROM THE ROOM THERMOSTAT / TIMER TERMINAL B WHEN THE TIMER OR OPENTHERM ROOM THERMOSTAT CONNECTED THE BOILER.
2.11. TYPICAL INSTALLATION DIAGRAM 2.11.1. Connection diagrams for the electronic board of the auxiliary equipment of boilers and cascade control Minerwa System 25 L L L L MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
2.11.2. Wiring diagrams for the Minerwa System 25 boiler auxiliary electronic board, cascade control and 1 low temperature zone system (underfloor heating). L L L L...
2.11.3. Scheme with One Boiler: 1 radiator circuit Minerwa System 25 MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
2.11.5. Typical Installation Scheme Cascade System with Minerwa System 25 Figure 46 Cascade System with Minerwa System and 1 Radiator (High Temperature) Circuit + Floor Heating (Low Temperature) Circuit and Hot Water Storage Tank Scheme Example MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
Our Authorized Service will give you required information about use of the boiler after performing initial controls and starting for the first time. Figure 47 Control panel of Minerwa 25 and Minerwa Perform below given controls prior to use: System 25 •...
• Service technician function radiator + tap displayed. (Only for authorized service, wait for the function to end without touching.) CH: (System) Central Heating DHW: Domestic Hot Water MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
In such case, combi boiler that position, initially gets into Radiator adjust the Domestic Hot Water temperature between 35 – 60 position, its symbol flashes on the left bottom corner of °C with (7) and (8) numbered buttons below the screen and tap symbol RESET button.
After connecting the Outside Sensor, adjustment is made according to average external weather temperature Figure 49 Thermostat position of your province with P04 parameter. Our authorized service will make this adjustment during installation.. MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
3.2. CUSTOMIZING COMBI BOILER Air Deareation Function FEATURES The boiler has to be switched to OFF mode first. It is possible to activate deaeration function pressing RESET As your combi boiler has an advanced electronic card, for circle time. operation conditions and certain parameters related with your preferences may be changed by our Authorized Service.
4-) Check boiler gas suppy valve bellow the boiler is open or not 5-) RESET boiler at first check if problem removed 6-) Call for authorised service MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
Page 40
Error Description of Malfunction Probable Cause Solution(s) Code the Error E 06 No ignition Boiler does not > Gas supply failure 1-) RESET boiler at first check if problem work, E06 error removed code flashing on 2-) Check boiler central heating valves are the screen open if they are closed open all 3-) Check all radiator valves are open if...
Page 41
1-) Call for authorised service at first more than 6 work, E41 error water successive times code flashing on request in short period ( the screen 1 min ) > Low gas pressure MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
Page 42
Error Description of Malfunction Probable Cause Solution(s) Code the Error E 42 Buttons anomaly Boiler does not Wrong parameters settled 1-) Call For service work, E42 error on TsP menu code flashing on the screen E 43 Opentherm Boiler does not Opentherm line 1-) Remove energy from boiler and re Communication...
Page 43
RESET the boiler (supposed) E84 error code 2-) IF problem persist Call for authorised low gas inlet flashing on the service pressure screen MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
Page 44
Error Description of Malfunction Probable Cause Solution(s) Code the Error E 87 Problem on Boiler does not > Cabling disconnections 1-) Call for authorised service at first electronic gas work, E87 error > Gas valve failiure valve circuit code flashing on the screen E 88 Fault of...
Page 45
(1) Call the Authorized Service if failure continues. (2) 81 numbered failure corresponds any blocking in the exhaust gas pipe. In such case, you should consult the authorized service technician before re-starting the combi boiler. MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
Reducing This warranty given by WARMHAUS does not cover radiator valves of rooms not used for a long period or if elimination of failures arising from abnormal use of the...
3. Keep the “SERVICE DOCUMENT” if received from your service technician following the service taken. The Service Document will be beneficial for you in any problems those may occur in your device in the future. MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
4. TECHNICAL DATA MINERWA 25 TECHNICAL SPECIFICATION UNIT BURGUNDY - GRAY - JET BLACK - WHITE CE certification CE-1015CT0706 :18 ?? Gas Circuit Gas type Gas supply pressure mbar Gas Consumption at Maximum m³/h 2,38* 2,85 0,728 0,92 Gas Consumption at Minimum m³/h...
European directives. Differences to product information listed elsewhere may result in different test conditions. Only the data that is contained in this product information is applicable and valid. (*) Electricity (**) Fuel (Natural Gas - G20) 4.2. ENERGY LABEL Minerwa 25 2019 MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
Page 50
Auxiliary boiler — Brand Name Warmhaus Warmhaus Isıtma ve Sogutma Sistemleri San. Tic. A.Ş. Manufacturer adress Taşpınar Mahallesi, TEKNOSAB 1. Cadde No: 12, 16700, Karacabey /- Bursa / Turkey All spesific precautions for assembly, installation and maintanance are described in the operating and installation manual.
Page 51
Packaged Weight Clearances Above Casing Clearances Below Casing Clearances Front - Operational Clearances Front - Servicing Clearances Right Hand Side Clearances Left Hand Side Sound Level NOx Classification MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
- Ensure that no electricity interruption is available at In order to keep the combi boiler within scope of your home. warranty; first start must be performed by WARMHAUS - Ensure that no grid water interruption is available at Authorized Service. Below given initial preparations your home.
4.5. CONTROLS FOR INITIAL OPERATION OF COMBI BOILER In order to keep the combi boiler within scope of warranty; first start must be performed by WARMHAUS Authorized Service. Below given initial preparations should be performed prior to authorized service appointment request: BOILER COMMISSIONING Form NO: SSH-FR 00 -000-01 R.T:13.04.2021...
Page 54
There is an earthed socket at a maximum distance of 50 cm from the device or a 2-4 Amp (N or W) automaton mounted on the electrical phase connection must be connected. If there is no earthed socket, a 3x1.5 TTR cable must be drawn from the nearest junction box and a grounded socket must be installed or a (N or W) automaton mounted on the electrical phase connection must be installed (The device must not be activated with a mobile extension cable) "Is the grounding of the device made in accordance with the standards? In places where there is no earthing, zeroing will not be...
Page 55
All goods are sold subject to our standard Conditions of Sale which are available on request. MINERWA 25 COMBI & SYSTEM BOILERS INSTALLATION & USER MANUAL-CODE-ENG • 15011606000215...
Need help?