The appliance shall be stored in a room
without continuously operating ignition
sources (for example: open flames, an oper-
ating gas appliance or an operating electric
heater).
•
Do not pierce or burn.
•
Be aware that the refrigerants may not con-
tain an odour.
•
Appliance should be installed, operated and
stored in a room with a floor area according
to the amount of refrigerant to be charged.
For specific information on the type of gas
and the amount, please refer to the relevant
label on the unit itself. When there are differ-
ences between the lable and the manual on
the Min. room area description, the descrip-
tion on label shall prevail.
amount of
Min. room
refrigerant
area (m
)
2
(kg)
> 0.0836 and
5
< 0.1045
> 0.1045 and
6
< 0.1254
> 0.1254 and
7
< 0.1463
> 0.1463 and
8
< 0.1672
> 0.1672 and
9
< 0.1881
> 0.1881 and <
10
0.2090
•
Compliance with national gas regulations
shall be observed. Keep ventilation open-
ings clear of obstruction.
•
The appliance shall be stored so as to pre-
vent mechanical damage from occurring.
•
A warning that the appliance shall be stored
in a well-ventilated area where the room
size corresponds to the room area as speci-
fied for operation.
•
Any person who is involved with working on
or breaking into a refrigerant circuit should
hold a current valid certificate from an
industry-accredited assessment authority,
which authorises their competence to han-
dle refrigerants safely in accordance with
an industry recognised assessment specifi-
cation. Servicing shall only be performed as
recommended by the equipment manufac-
turer. Maintenance
•
and repair requiring the assistance of other
skilled personnel shall be carried out under
the supervision of the person competent in
the use of flammable refrigerants.
amount of
Min. room
refrigerant
area (m
)
2
(kg)
> 0.2090 and
11
< 0.2299
> 0.2299 and
12
< 0.2508
> 0.2508 and
13
< 0.2717
> 0.2717 and
14
< 0.2926
> 0.2926 and
15
< 0.3135
Air conditioner portable
•
The appliance shall be stored in a room
without continuously operating open flames
(for example an operating gas appliance)
and ignition sources (for example an oper-
ating electric heater).
Explanation of symbols displayed on the unit
(For the unit adopts R32/R290 Refrigerant only):
Caution: Risk of fire/ flammable
materials
WARNING
This symbol shows that this
appliance used a flammable
refrigerant. If the refrigerant
is leaked and exposed to an
external ignition source, there
is a risk of fire.
CAUTION
This symbol shows that the
operation manual should be
read carefully.
CAUTION
This symbol shows that a
service personnel should be
handling this equipment with
reference to the installation
manual.
CAUTION
This symbol shows that infor-
mation is available such as the
operating manual or installa-
tion manual.
1. Transport of equipment containing flamma-
ble refrigerants See transport regulations
2. Marking of equipment using signs
See local regulations
3. Disposal of equipment using flammable
refrigerants See national regulations.
4. Storage of equipment/appliance. The stor-
age of equipment should be in accordance
with the manufacturer's instructions.
5. Storage of packed (unsold) equipment
Storage package protection should be
constructed such that mechanical damage
to the equipment inside the package will
not cause a leak of the refrigerant charge.
The maximum number of pieces of equip-
ment permitted to be stored together will be
determined by local regulations.
6. Information on servicing
•
Checks to the area
Prior to beginning work on systems contain-
ing flammable refrigerants, safety checks are
necessary to ensure that the risk of ignition
is minimised. For repair to the refrigerating
system, the following precautions shall be
complied with prior to conducting work on
the system.
•
Work procedure
Work shall be undertaken under a controlled
5
Need help?
Do you have a question about the EACM-09 CG/N6 and is the answer not in the manual?