Installation Manual of Room Air Conditioner

Preparation
Necessary Tools for Installation
Driver
Nipper
Hacksaw
Hole core drill
Spanner(17,19 and 26mm)
Gas leakage detector or
soap-and-water solution
Power Source
Before inserting power plug into receptacle, check the voltage without fail.
The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be
reached.Do not extend the cable by cutting it.
Drawing for the installation of indoor and outdoor units
The models adopt HFC free refrigerant R410A
more than 5cm
more than
10cm
Arrangement of piping
directions
Rear left
Left
Below
The marks from
to
A
in the figure are the
G
parts numbers.
The distance between
the indoor unit and the
floor should be more
than 2m.
more than 60cm
Please be subject to the actual product purchased , the above picture is just for your reference.
Read this manual before installation
Explain sufficiently the operating means to the user according to this manual
NO.00105
Torque wrench
(17mm,22mm,26mm)
Pipe cutter
Flaring tool
Knife
Measuring tape
Reamer
Rear
right
Right
more than 10cm
more than 10cm
Indoor Unit
Place, robust not causing vibration, where the body can be supported sufficiently.
Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the
unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the outdoor unit.
Place, where cold air can be spread in a room entirely.
Place, nearby a power receptacle, with enough space around. (Refer to drawings).
Place where the distance of more than lm from televisions, radios, wireless apparatuses
and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the indoor unit can
receive signals when the fluorescent lamps in the room are lightened.
Outdoor Unit
Place, which is less affected by rain or direct sunlight and is sufficiently ventilated.
Place, possible to bear the unit, where vibration and noise are not increased.
Place, where discharged wind and noise do not cause a nuisance to the neighbors.
Place, where a distance marked
Attention must be paid to
the rising up of drain hose
G
more than 10cm
F
A
C
D
more than15cm
Selection of Installation Place
is available as illustrated in the above figure.
Optional parts for piping
Non-adhesive tape
A
Adhesive tape
B
Saddle (L.S) with screws
C
Connecting electric cable
D
for indoor and outdoor
E
Drain hose
F
Heating insulating material
Piping hole cover
G
Floor fixing dimensions of the
outdoor unit (Unit:mm)
Fixing of outdoor unit
Fix the unit to concrete or block
with bolts (10mm) and nuts firmly
and horizontally.
When fitting the unit to wall
surface, roof or rooftop, fix
a supporter surely with nails
or wires in consideration of
E
earthquake and strong wind.
If vibration may affect the
house, fix the unit by attaching a
vibration-proof mat.

Advertisement

Table of Contents
loading

Summary of Contents for Haier HSU-09HEA103

  • Page 1: Installation Manual Of Room Air Conditioner

    Place, robust not causing vibration, where the body can be supported sufficiently. Hacksaw Pipe cutter Place, not affected by heat or steam generated in the vicinity, where inlet and outlet of the Hole core drill Flaring tool unit are not disturbed.
  • Page 2: Indoor Unit

    When connecting the cable before installing the indoor unit Ø60mm Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then...
  • Page 3: Outdoor Unit

    Be careful that matters, such as wastes of sands, etc. shall not enter the pipe. The standard pipe length is 5m. If it is over 7m, the function of the unit will be affected. If the pipe has to be lengthened, the refrigerant should be charged, according to 20 g/m.
  • Page 4 To prevent the gas leakage, turn the service port’s cap, the valve rod’s cap for 2-way valve and 3-way’s a little more than the point where the torque increases suddenly. confirm that drainage Please pour water in the drain pan of the indoor unit, and is carried out surely to outdoor.
  • Page 5 Instale el aparato en un circuito dedicado de alimentación. ● Elija un lugar que permita soportar el peso de la unidad y que no amplifique el ruido y las Debe existir una toma al alcance del cable de alimentación. No trate de prolongar vibraciones.
  • Page 6: Unidad Interior

    Acolchado (4) calor de la unidad interior. 2. Inserte los cables eléctricos de interior / exterior a través de la parte trasera de la unidad interior y tire de ellos desde la parte delantera. A continuación, conéctelos. Placa de montaje (1) Codo de drenaje (1) 3.
  • Page 7: Unidad Exterior

    Procure que no penetren materiales, como residuos o arena, en el tubo. La longitud estándar del tubo es de 5m. Si el tubo tiene más de 7m, se verán afectadas las funciones de la unidad. Si es necesario alargar el tubo, deberá cargarse refrigerante adicional a razón de 20 g/m.
  • Page 8 ● No practique el drenaje como se muestra a continuación. 7. Para evitar fugas de gas, gire el tapón del puerto de mantenimiento y el tapón del vástago de las válvulas de 2 y 3 vías un poco por encima del punto en el que la torsión aumenta súbitamente.
  • Page 9: Schema Per L'installazione Dell'unità Interna Ed Esterna

    Più di 60cm Più di 15cm Attenersi al prodotto acquistato: le immagini sono solo per riferimento. Leggere questo manuale prima dell’installazione Spiegare all’utente in modo esauriente il funzionamento e l’uso del condizionatore in base alle istruzioni di questo manuale.
  • Page 10: Parti Accessorie

    (Sezione del foro su parete) Tubo del foro tubatura ● Tirare leggermente il cavo per accertarsi che i cavi siano stati inseriti e fissati in modo appro- priato. ● Dopo avere collegato i cavi, non dimenticare mai di stringere i cavi collegati con la copertura dei cavi.
  • Page 11 1. Staccare il coperchio della porta di servizio della valvola a 3 vie, il coperchio della valvola a stelo della valvola a 2 vie e della valvola a stelo della valvola a 3 vie, col- legare la porta di servizio nella protuberanza del tubo di carico (basso) del gruppo monometrico.
  • Page 12 ● Non installare lo scarico come mostrato di seguito. riempire con refrigerante raccomandato usando la bombola del gas. 6. Staccare il tubo di carico dalla porta di servizio, aprire la valvola a 2 vie ed a 3 vie. Girare l'asta della valvola in senso antiorario delicatamente.
  • Page 13 Unité extérieure source d'alimentation correspond aux informations sur la plaque signalétique. ● Sélectionnez un emplacement qui ne soit pas exposé à la pluie ou à la lumière du jour et Installez un circuit d'alimentation auxiliaire exclusive. qui soit suffisamment ventilé.
  • Page 14: Unité Intérieure

    ● Connectez au préalable le câble des unités intérieures/extérieures et recouvrez ensuite les câbles connectés avec l'isolation. 1. Exécutez une mise à niveau correcte de la plaque à fixer contre le mur en fonction des piliers ou des linteaux autour, puis attachez la plaque temporairement avec un Fixation de l'unité...
  • Page 15: Unité Extérieure

    Lorsque vous courbez un tuyau, donnez-lui autant de rondeur que possible afin de ne pas l’écraser ; le rayon de courbure doit être d’au moins 30 à 40 mm, voire plus. Connectez d'abord le côté gaz pour faciliter la suite des travaux.
  • Page 16 3. 4. En tournant dans le sens antihoraire, ouvrez le robinet de la vanne à 2 voies à un 4. Tuyau d'évasement angle de 90 degrés. Environ 6 secondes plus tard, fermez la vanne à 2 voies et ins- 3.Insérez l'écrou...

Table of Contents