Installation Manual of Room Air Conditioner

1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
Accessory parts
No.
Accessory parts
1
Remote controller
2
R-03 dry battery
3
Mounting plate
4
Drain hose
4X50
5
Steel nail, cement
6
4X25
Plastic cap
Screw
7
Cover
8
Cushion
9
Pipe supporting plate
10
Drain-elbow
No.001050
Necessary Tools for Installation
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
Drawing for the installation of indoor and outdoor units
Number
of
articles
1
Optional parts for piping
Mark
Parts name
2
A
Non-adhesive tape
Adhesive tape
B
1
C
Saddle(L.S) with screws
Connecting electric cable
D
for indoor and outdoor
1
Drain hose
E
F
Heating insulating material
6
Piping hole cover
G
4
1
Arrangement of piping directions
4
Left
1
1
Read this manual before installation
Explain sufficiently the operating means to the user
according to this manual.
Rear left
Rear
right
Right
Below
The marks from
A
The distance between the indoor unit and the floor should be
more than 2m.
9.Nipper
10.Gas leakage detector or
soap-and-water solution
11.Measuring tape
Attention must be paid to
the rising up of drain hose
to
in the figure are the parts numbers.
G
12.Reamer
A
C
D
E

Advertisement

Table of Contents
loading

Summary of Contents for Haier HSU-07HEA03/R2 - annexe 1

  • Page 1: Installation Manual Of Room Air Conditioner

    Arrangement of piping directions Cushion Rear left Rear Left right Pipe supporting plate Right Below Drain-elbow The marks from in the figure are the parts numbers. The distance between the indoor unit and the floor should be more than 2m. No.001050...
  • Page 2: Selection Of Installation Place

    Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate. Install an exclusive branch circuit of the power. A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it. Selection of pipe...
  • Page 3: Installation Of The Indoor Unit

    In case of left side piping, cut away, with a nipper, the lid for left piping. In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on heat insulation materials.
  • Page 4 Indoor unit 1. Insert the drain hose into the dent of heat insulation materials of indoor unit. 2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them. 3. Coat the flaring seal face with refrigerant oil and connect pipes.
  • Page 5: Connecting The Indoor/Outdoor Electric Cable

    1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW).
  • Page 6: Installation Of Outdoor Unit

    3.Connection Use the same method on indoor unit. Loosen the screws on terminal block and insert the plugs fully into terminal block, then tighten the screws. Insert the cable according to terminal number in the same manner as the indoor unit.
  • Page 7: Purging Method

    Charge according to the following list. Piping length Additional amount No need Note: When extending piping, air inside piping shall be removed by using external refrigerant gas, charge according to the following list. or 80g Brand new outdoor unit is charged 50g...
  • Page 8 Please pour water in the drain pan of the indoor unit, and confirm that drainage is carried out surely to outdoor. In case that the attached drain hose is in a room, please apply heat insulation to it without fail.
  • Page 9 The products are fulfilled with the requirements in the directive 2002/95/EEC of the local and national legislation. Air conditioners must be European parliament and of the council on the Restriction of the use of Certain Haz- treated at a specialized treatment facility for re-use, recycling and recovery.
  • Page 10 WEEE cias negativas para el entorno y para la salud de las personas. Contacte, por De acuerdo con la directiva 2002/96/CE del parlamento Europeo, Informa- favor, con el instalador o con las autoridades locales para obtener más infor- mos al consumidor acerca del reciclage de los productos Electrónicos y...
  • Page 11 IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED This product contains fluorinated greenhouse gases covered by the Kyoto The filled out label must be adhered in the proximity of the product charging Protocol. Do not vent into the atmosphere. port (e.g. onto the inside of the stop valve cover).
  • Page 12 INFORMACIÓN IMPORTANTE EN RELACIÓN AL REFRIGERANTE UTILIZADO Este producto contiene los gases fluorados de efecto invernadora regulados La etiqueta rellenada debe pegarse cerca de la conexión de carga del pro- por el Protocolo de Kioto. No vierta gases a la atmósfera.

Table of Contents