Installation of Indoor Unit

CONNECTION PIPE REQUIREMENT

Table 1
M o d e l
AC142ACBEA
AC182ACBEA
AC242ACBEA AC28NACBEA
AC36NACBEA AC42NACBEA

INSTALLATION PROCEDURE

Install the room air conditioner as follows:
PREPARING INDOOR UNIT INSTALLATION
1. REMOVE THE INTAKE GRILL
Open the intake grill and remove the
three or four or six screws.(Fig. 1)
Remark: The main unit can be wired before
the indoor unit is installed. Select
the most appropriate installation
order.
A. FLOOR CONSOLE TYPE
(For series 36,42 no this type )
1. DRILLING FOR PIPING
Select piping and drain directions.(Fig.2) (Series14,18,24)
The piping and drain can be made in three directions as shown below.
For series 28,36,42 can be made rear and down two directions.
(Fig. 2)
The drain hose can be connected to either the left or right side.(Fig.3) For series 28,36,42.only right side.
(Fig.3)
Drain hose (Left side)
Diameter
Liquid side
6.35 mm
6.35 mm
9.52 mm
9.52 mm
Tapping screw
Intake grill
rear
right
down
When the directions are selected, drill a 7 cm dia. hole on the wall so
that the hole is tilted downward toward the outdoor for smooth water
flow. When the pipe is led out from the rear, make a hole in Fig.6, at
the position shown.
Drain hose (Right side)
Maximum
length
Gas side
12.7 mm
30 m
15.88 mm
30 m
30 m
15.88 mm
19.05mm
50 m
(Fig. 1)
Machine screw
For series 28,36,42, have not the power plug.
14
Maximum height
(between indoor
and outdoor)
20 m
20 m
20 m
30 m
Tapping screw