Plc and iiot edge controller
Table of Contents

Advertisement

Quick Links

TX800M/L
PLC and IIoT Edge
Controller
Instructions for Use

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TX800M and is the answer not in the manual?

Questions and answers

Summary of Contents for turck TX800M

  • Page 1 TX800M/L PLC and IIoT Edge Controller Instructions for Use...
  • Page 2: Table Of Contents

    Charging the battery.................... 21 Initial commissioning.................... 21 7.2.1 User management ........................ 21 Web server login ...................... 22 Setting the IP address .................... 23 V01.00 | 2024/03 | 2 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 3 12 Disposal..............................  33 13 Technical data...........................  34 14 Appendix: approvals and markings .....................  36 15 Turck branches — contact data .................... 37 V01.00 | 2024/03 | 3 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 4: About These Instructions

    If you have any suggestions for improving the design or if some information is missing in the document, please send your suggestions to techdoc@turck.com. V01.00 | 2024/03 | 4 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 5: Notes On The Product

    Type designation TX800L 100046998 Year/week of production A2412 Internal version ID of the product V.: … Serial number S.N.: AA…AA V01.00 | 2024/03 | 5 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 6: Type Code

    Power supply connector Connector for serial interface Quick Start Guide Turck service Turck supports you in your projects – from the initial analysis right through to the commission- ing of your application. The Turck product database at www.turck.com offers you several soft- ware tools for programming, configuring or commissioning, as well as data sheets and CAD files in many export formats.
  • Page 7: For Your Safety

    The product is designed according to state of the art technology. Residual hazards, however, still exist. Observe the following safety instructions and warnings in order to prevent danger to persons and property. Turck accepts no liability for damage caused by failure to observe these safety instructions.
  • Page 8: Note On Explosion Protection (Usa And Canada Only)

    Do not disconnect the device in an ignitable atmosphere when energized. Conditions resulting from Ex approvals for use in Zone 2 The ATEX or IECEx approval currently only applies to the TX800L. The TX800M (expected to be available from Q4/2024) is not ATEX or IECEx certified, yet.
  • Page 9: Product Description

    The device is designed in protection class IP20. For the connection to Ethernet, two (TX800M) or three (TX800L) Ethernet ports are available. The serial port is used to communicate with a PLC or with field devices with RS232 or RS485 in- terface.
  • Page 10: Properties And Features

    OPC UA server (with CODESYS or TX VisuPro) OPC UA client and MQTT (with TX VisuPro) Serial communication via RS232, RS485 and RS422 V01.00 | 2024/03 | 10 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 11: Interfaces

    Specification Format FAT, FAT32 Max. size Limited by FAT32 specifications ≤ 4 GB for a single file ≤ 32 GB V01.00 | 2024/03 | 11 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 12: Accessories

    2.4 GHz and 5 GHz 100010167 TX-DP-S PROFIBUS-DP slave, 12 Mbaud 4.4.2 Power supply Type Description 100002938 TX-PSC TX power supply onnector V01.00 | 2024/03 | 12 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 13: Installing

    Installing plug-in modules Fig. 5: Installing plug-in modules Fig. 6: Installing plug-in modules (e. g. TX-CAN, TX-IO-DX06) (e. g. TX-IO-XX03) V01.00 | 2024/03 | 13 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 14: Grounding The Device

    (1 MΩ resistor with 4.7 nF capacitor connected in parallel). „ The power supply must have double or reinforced insulation. Fig. 7: Power supply – wiring V01.00 | 2024/03 | 14 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 15: Connecting

    Ethernet port 1 (10/100 Mbps) Ethernet port 0 (10/100 Mbps) USB ports, V2.0, max. 500 mA Expansion slot for plug-in modules SD card slot V01.00 | 2024/03 | 15 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 16: Connecting Tx800L

    Ethernet port 1 (10/100 Mbps) Serial interface Ethernet port 0 (10/100/1000 Mbps) Power supply 2 extension slots for plug-in modules SD card slot V01.00 | 2024/03 | 16 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 17: Connecting The Power Supply

    Fig. 10: Power supply connector TX… NOTE The power connector is part of the scope of delivery and can be ordered as spare part [} 12]. V01.00 | 2024/03 | 17 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 18: Connecting External Devices To The Serial Interface

    To operate in RS485, pins 1 and 2 as well as pins 3 and 4 must be connected extern- ally. V01.00 | 2024/03 | 18 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 19: Connecting Plug-In Modules

    TX-CAN 1 only for TX800M 2 only for TX800L TX-RS485 RS485/RS422 Serial TX-RS232 RS232 Serial TX-IO-DX06 Compact I/O V01.00 | 2024/03 | 19 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 20: Slot Assignment - Can Port

    Mode COM3 COM Port 3 Slot 1 to Slot 4 refer to the extension slots on the rear of the device. V01.00 | 2024/03 | 20 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 21: Commissioning

    Initial commissioning The IP address of Ethernet port ETH1 is set to 192.168.1.254 by default. The web server (System Settings) can be opened via this IP address using a web browser, the Turck Automation Suite (TAS) or the Turck Service Tool.
  • Page 22: Web Server Login

    IP address for Ethernet port ETH1 has already been changed, than the current IP address of the port is entered here. V01.00 | 2024/03 | 22 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 23: Setting The Ip Address

    The IP addresses of the device can be set via the web server of the device. The IP address via which the device is connected to the PC via Ethernet can also be set via the Turck Service Tool or via the Turck Automation Suite (TAS).
  • Page 24: Setting The Ip Address Via Turck Service Tool

    Turck Service Tool shows the connected devices. NOTE Clicking the device's IP address opens the web server. Fig. 19: Turck Service Tool – found devices V01.00 | 2024/03 | 24 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 25: Setting The Ip Address Via Tas (Turck Automation Suite)

    Fig. 21: Turck Automation Suite: Scan network The Turck Automation Suite shows the connected devices. Fig. 22: Turck Automation Suite: found devices V01.00 | 2024/03 | 25 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 26: Programming With Codesys

    EtherCAT OPC-UA 7.5.2 Access to the CODESYS WebVisu The CODESYS WebVisu is accessed via port 8085: http://<<IP address>>:8085/webvisu.htm Example: http://192.168.1.40:8085/webvisu.htm V01.00 | 2024/03 | 26 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 27: Programming With Tx Visupro

    Project transfer via a USB stick „ Create an update package with TX VisuPro and copy it to a USB stick. V01.00 | 2024/03 | 27 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 28: Configuring

    In addition to the options in user mode, the system mode includes ad- ditional commands for system upgrade and recovery. Device without TX VisuPro runtime Device with software error V01.00 | 2024/03 | 28 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 29 Services Activate/deactivate services (e.g. OpenSSH server, bridge, cloud, router, SNMP, logging) V01.00 | 2024/03 | 29 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 30 By default, the device is restarted in user mode via the "Main OS" op- tion. The "Configuration OS" option restarts the device directly in Sys- tem Settings in System Mode. V01.00 | 2024/03 | 30 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 31: Operating

    LED orange (left LED) Meaning No Ethernet connection Ethernet connection established LED green (right LED) Meaning No data transfer Flashing Data transfer V01.00 | 2024/03 | 31 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 32: Troubleshooting

    If there are no faults, there is a device malfunction. In this case, decommission the device and replace it with a new device of the same type. V01.00 | 2024/03 | 32 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 33: Repair

    The device the lithium battery must be disposed of properly in accordance with WEEE Directive 2012/19/EU and does not belong in normal household waste. V01.00 | 2024/03 | 33 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 34: Technical Data

    For applications requiring compliance with EN 61131-2 and specifically in reference to 10 ms voltage dips, the minimum power supply voltage is 18 VDC. V01.00 | 2024/03 | 34 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 35 Port: DC mains 0 %, duration: 10 ms, 20 fields × 1 s Test executed on the 24Vdc of the EUT EN 61000-4-29 V01.00 | 2024/03 | 35 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 36: Appendix: Approvals And Markings

    Appendix Appendix: approvals and markings The ATEX or IECEx approval currently only applies to the TX800L. The TX800M (expected to be available from Q4/2024) is not ATEX or IECEx certified, yet. Approvals DEMKO 20 ATEX 2333X ÉII 3 G Ex ec IIC T5…T4 Gc IECEx ULD 20.0001X...
  • Page 37: Turck Branches - Contact Data

    Via San Domenico 5, IT-20008 Bareggio (MI) www.turckbanner.it Japan TURCK Japan Corporation ISM Akihabara 1F, 1-24-2, Taito, Taito-ku, 110-0016 Tokyo www.turck.jp V01.00 | 2024/03 | 37 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 38 United Kingdom TURCK BANNER LIMITED Blenheim House, Hurricane Way, GB-SS11 8YT Wickford, Essex www.turckbanner.co.uk Turck Inc. 3000 Campus Drive, USA-MN 55441 Minneapolis www.turck.us V01.00 | 2024/03 | 38 Hans Turck GmbH & Co. KG | T +49 208 4952-0 | more@turck.com | www.turck.com...
  • Page 39 Over 30 subsidiaries and 60 representations worldwide! 100048214 | 2024/03 100048214 www.turck.com...

This manual is also suitable for:

Tx800l

Table of Contents