Elimko E-200 Series User Manual

Elimko E-200 Series User Manual

Universal advanced controllers
Hide thumbs Also See for E-200 Series:

Advertisement

Quick Links

Elimko
E-200 controller is designed for panel mounting and should be
used in an industrial environment.
The package of E-200 controller contains;
Controller, 2 pieces of mounting clamps,
User manual, Guarantee certificate
After opening the package, please check the contents with the
above list. If the delivered product is wrong type,any item is
missing or there are visible defects, contact the vendor from
which you purchased the product.
Before installing and operating the controller, please read the
user manual thoroughly.
The installation and configuration of the controller must only be
performed by a person qualified in instrumentation.
Keep the unit away from flamable gases, that could cause
explosion.
Do not use alcohol or other solvents to clean the controller.
Use a clean cloth soaked in water tightly squeezed to gently
wipe the outer surface of the controller.
The instrument is not used in medical applications.
EU DIRECTIVE COMPLIANCE
Low Voltage Directive
EN 61010-1
EMC Directive
EN 61326-1
K - Q
TSE-ISO-EN
9000
TS EN ISO 9001
Quality Management System Certificate
E-200
KY-200-1121-0
E-200 Series
Universal Advanced
Controllers
User Manual
8. 8 . 8 . 8 .
129. 2
8. 8 . 8 . 8 .
122. 2
Manufacturer / Technical Support
Elimko Elektronic Production and Control Co. Ltd.
8. Cad. 21.Sok. No:16 Emek 06510 Ankara / TURKEY
Phone: + 90 312 212 64 50 Fax: + 90 312 212 41 43
www.elimko.com.tr • e-mail:elimko@elimko.com.tr
E-200
Index
• Description...............................................................................
• Technical Specifications...........................................................
• Type Coding.............................................................................
• Dimensions..............................................................................
• Panel Mounting........................................................................
• Front Panel.........................................................................
• Connection Diagrams.........................................................
• Error Messages......................................................................
• Input Type and Ranges..........................................................
• Alarm Types...........................................................................
• Auto-Tune...............................................................................
• Manual Tuning........................................................................
• Feedback Valve Control..................................................
• Open-Loop Valve Control.......................................................
• Operator Pages......................................................................
• Automatic Mode Operator Page.............................................
• Manual Mode Operator Page.........................................
• Configuration Pages.......................................................
• PID Tuning Page...................................................................
• Set Point Configuration Page................................................
• Alarm Configuration Page...............................................
• Control and Output Configuration Page............................
• Genaral Configuration Page...........................................
• Security Adjustment Page......................................................
• Calibration Page.............................................................
• Communication Data......................................................
• Tables..............................................................................
• Footnotes...............................................................................
200
Elimko
6 - 7
8 - 9
15 - 16
20 - 21
22 - 23
26 - 27
28 - 31
32 - 34
36 - 39
40 - 44
45 -49
1
2
3
4
4
5
10
11
12
13
14
17
18
19
24
25
35
50

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the E-200 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Elimko E-200 Series

  • Page 1: Table Of Contents

    8. 8 . 8 . 8 . 122. 2 Manufacturer / Technical Support Elimko Elektronic Production and Control Co. Ltd. 8. Cad. 21.Sok. No:16 Emek 06510 Ankara / TURKEY Phone: + 90 312 212 64 50 Fax: + 90 312 212 41 43 www.elimko.com.tr •...
  • Page 2: Technical Specifications

    E-200 2. Technical Specifications 1. Definition E-200 Series Universal Profile Controllers are designed to use On/Off Thermocouple ( TC ) : B, E, J, K, L, N, R, S, T, U and PID Control Techniques, by using new generation Resistance Thermometer ( RT ) : Pt-100 Input Types microcontrollers.
  • Page 3: Front Panel

    Elimko Elimko E-200 E-200 6. Front Panel 6. Front Panel Lower - While in normal operation, it displays the control set Display point (Automatic mode) or manual output 8. 8 . 8 . 8 . R1 Led (Manual mode). Upper...
  • Page 4: Error Messages

    Elimko Elimko E-200 E-200 8. Error Messages 9. Input Types and Ranges TEMPERATURE SENSORS Message Meaning Remedy Temperature Range Sensor Type Standart ( C) ( F) Check the sensor The connection of the sensor is 60 , 1820 Type B...
  • Page 5: Manual Tuning

    Elimko Elimko E-200 E-200 12. Manual Tuning 13. Feedback Valve Control If for any reason Auto-tuning gives unsatisfactory results, the controller can be tuned manually. There are a number of standard methods for Last Control Unit manual tuning. The one described here is the Ziegler-Nichols method.
  • Page 6: Operator

    Elimko Elimko E-200 E-200 15. Operator Pages 16. Automatic Mode Operation Page  When the controller power is switched on, it runs through a self-test sequence for about 2 seconds and displays the version number and then enters into normal operation.
  • Page 7: Configuration

    Elimko Elimko E-200 E-200 Input to Configuration Pages 18. Configuration Pages  The fundamental characteristics of the controller are specified in configuration pages. These pages: TUNE = PID Tuning Page Normal SETP = Set Points Configuration Page Operation ACNF = Alarm Configuration Page OCNF = Control and Output Configuration Page ...
  • Page 8: Alarm Configuration Page

    Elimko Elimko E-200 E-200 21. Alarm Configuration Page (PAGE=ACNF) 21. Alarm Configuration Page (PAGE=ACNF) (continue on next page) Elimko Elimko E-200 E-200 22. Control and Output Configuration Page 22. Control and Output Configuration Page (page=ocnf) (page=ocnf) (continue on next page)
  • Page 9 Elimko Elimko E-200 E-200 22. Control and Output Configuration Page 22. Control and Output Configuration Page (page=ocnf) (page=ocnf) (continue on next page) Elimko Elimko E-200 E-200 23. General Configuration Page (PAGE=GCNF) 23. General Configuration Page (PAGE=GCNF) (continue on next page)
  • Page 10: Security Adjustment Page

    Elimko Elimko E-200 E-200 23. General Configuration Page (PAGE=GCNF) 24. Security Adjustments Page (PAGE=PRTC) Elimko Elimko E-200 E-200 25. Calibration Page (PAGE=CLBR) 25. Calibration Page (PAGE=CLBR) (continue on next page) (continue on next page)
  • Page 11 Elimko Elimko E-200 E-200 25. Calibration Page (PAGE=CLBR) 25. Calibration Page (PAGE=CLBR) Analog Input 50 mV Calibration: Set the calibrator as a milivolt Analog Output Low Limit Calibration: The calibrator is set to milliamp or volt measurement, depending on the analog output type.
  • Page 12: Communication Data

    Elimko Elimko E-200 E-200 26. Communication Data (continue on next page) (continue on next page) Elimko Elimko E-200 E-200 26.Communication Data 27. Tables Table-1 Status In short Explanation (For 1) 1.Relay (RL1) Active 2.Relay (RL2) Active 3.Relay (RL3) Active 4.Relay (RL4) Active...
  • Page 13: Tables

    Elimko Elimko E-200 E-200 27. Tables 27. Tables Table-5 Table-10 Table-12 No Control NONE CO-1 “+” Directed Control Output 0A20 0-20 mA (Linear) “-” Directed Control Output Single-Sided (+) PID Control CO-2 4A20 4-20 mA (Linear) Double-Sided (+/-) PID DO-1...
  • Page 14: Footnotes

    Elimko E-200 Footnotes (1) If the set point source is external ( SPSR  INT ), this adjustment is not valid. (2) With the control type as open loop valve control ( CTYP = BND ), this screen is used for valve direction, instead of manual output value.

Table of Contents