Measure the PCBA, Motor and Internal Wire Assembly
LBX6000 Blower
4. Set the multimeter function to "Diode measuring".
5. Connect the black pen pin and red pen pin to the both
side of the fuse.
Notice: If the voltage is not exceed 0.05V, means a good
fuse, go to the next testing step; otherwise means a broken
fuse, replace a new PCBA.