DM422T Digital Stepper Drive User Manual 1. Features Step & direction (PUL/DIR) or double pulse control Input voltage 12~50VDC 500 KHz max pulse input frequency 4 microstep resolutions via DIP switches 8 output current settings via DIP Switches ...
Figure 1 Mechanical specifications Side mounting recommended for better heat dissipation 2.4 Elimination of Heat DM422T reliable working temperature should be < 40℃ (109°F) It is recommended to use automatic idle-current mode to reduce motor heating. That means set the SW4 ...
3.3 LED Light Indication There are two LED lights for DM422T. The GREEN one is the power indicator which will be always on generally. The RED one is a protection indicator which will flash 1-2 times in a 3-second period, when protection enabled for a DM422T.
Figure 7 4-lead Motor Connections 6. DIP Switch Configurations The DM422T has 6-bit, 4-bit DIP switch and a 1-bit DIP switch. The first 6-bit is used to configure settings of micro step resolution, output current, motor standstill current as shown below.
DM422T Digital Stepper Drive User Manual 6.2 Output Current Configurations The first three bits (SW1, 2, 3) of the DIP switch are used to set the dynamic current. Select a setting closest to your motor’s required current. Note: “default” means the parameters can be set by GUI tuning software.
DM422T Digital Stepper Drive User Manual 7. Sequence Chart of Control Signals In order to avoid some fault operations and deviations, PUL, DIR and ENA should abide by some rules, shown as following diagram: Figure 9 Sequence charts of control signals Remark: t1: ENA must be ahead of DIR by at least 200ms.