Page 1
Hob Mounted Adjustable Exposed Mixer Base Installation and Maintenance Instructions FS012ADJ technical data Working Pressure Range Min 50 kPa Max 500 kPa Maximum Static Pressure 1200 kPa Maximum Working Temperature 95°C (Jumper Valve) Inlet Connection 1/2” BSP Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA) and AS/NZS3500. Installations not complying with PCA and AS/NZS 3500 may void the product and performance warranty provisions.
installation BEFORE INSTALLATION • Ensure all operating and dimensional specifications are suitable for the intended installation. Check that there is no shelf or obstruction above. Shorter riser, hose & spring guard options are available from Enware • Check that wall bracket can be installed on a stable wall surface. If not, extra measures may need to be taken so that the bracket can be supported by a firm wall backing.
Page 3
2. Measure the centres of tap holes on bench, subtract 25mm from each end and mark this on each end of the breeching piece. Cut the breeching piece to the required length using tube cutters or similar hand tool. SEE IMAGE 02 3.
Page 4
FITTING LEVER HANDLES Fit colour indicator ring onto lever handle. To do this, place an indicator ring on flat surface with the rebated edge facing up. Fit spline adaptor onto Press the lever handle down onto TOOTH spindle. WASHER the indicator ring evenly until it clips into place.
Page 5
operating instructions OPERATING LEVER TAP To operate tap, turn handle lever in the directions indicated. Mixing Set (top view) Anti-Clockwise to close Clockwise to close WARNING Hot water will scald. Care must be taken to avoid scalding when using the trigger spray to deliver hot water.
maintenance CLEANING Enware products should be cleaned with a soft damp cloth using only mild liquid detergent or soap and water. Do not use cleaning agents containing a corrosive acid, scouring agent or solvent chemicals. Do not use cream cleaners, as they are abrasive. Use of unsuitable cleaning agents may damage the surface.
spare parts Description Enware Part Code O-rings (8), grub screws (4), & aerator (1) pack FS734 Lever handle with colour indicators FSJ378 (for new/old style lever handle) Lever Top Assembly (includes lever handle, Hot, Cold, Warm & Hob Mount / Wall Mount / Pot Filler (Pillar / Bib) - grey indicators, fixing screw &...
- WATTS AUSTRALIA EFFECTIVE FROM 20 November 2023 3. Our responsibilities This Warranty Statement applies to products supplied by Australian Valve (a) In the event that the Supplier is reasonably satisfied that there is a Group Pty Ltd (ACN 068 227 270) (AVG) or Enware Pty Ltd (ACN 662...
Need help?
Do you have a question about the ENWARE FS012ADJ and is the answer not in the manual?
Questions and answers