Instructions for Installing FS-200-W
General Purpose Liquid Flow Switch
Sizes: 1" – 6"
WARNING
!
Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information
can result in death, serious personal injury, property
damage, or damage to the equipment.
Keep this Manual for future reference.
WARNING
!
Local building or plumbing codes may require modifica-
tions to the information provided. You are required to
consult the local building and plumbing codes prior
to installation. If the information provided here is not
consistent with local building or plumbing codes, the
local codes should be followed. This product must be
installed by a licensed contractor in accordance with
local codes and ordinances.
WARNING
!
Electrical shock hazard. To prevent electrical shock,
death or equipment damage, disconnect power supply
before installing or servicing control.
The Watts FS-200-W Flow Switch is used to start or stop elec-
trically operated equipment such as burners, pumps or alarms
by detecting liquid flow through piping. It is designed for use in
water media applications and is not intended for use in hazard-
ous or corrosive fluids.
Flow Switch Location
The preferred installation of the FS-200-W is in a horizontal pipe with a straight run of
at least 5 pipe diameters on each side of the paddle (Figure 1). There should be no
restrictions from elbows, valves, orifices, etc. Refer to Table 1 below for flow rates.
The Flow Switch can be installed in a vertical pipe only if the flow direction of
the liquid is upward. Table 1 does not apply to vertical installations.
FIGURE 1
PIPE SIzE
FLOW INCREASES
MINIMuM
ADJuSTMENT
FLOW DECREASES
FLOW INCREASES
MAxIMuM
ADJuSTMENT
FLOW DECREASES
*Calculated for various pipe sizes. Flow rates may vary ±10% from values above.
TABLE 1 FLOW SPECIFICATIONS
1"
1
1
"
1
1
"
2"
2
1
4
2
2
4.5
8.1
11.8
16.5
25
2.2
6.8
7.6
9.3
19
14.8
22.1
25.7
32.3
75
13.8
20.1
23.7
30.5
72
CAUTION
!
• To prevent serious burns, boiler should be thoroughly cooled
before installing or servicing control.
• The FS-200-W is designed as an operating control. It is the
responsibility of the installer to provide safety or limit control on
installations where an operating control failure would result in
personal injury and/or property loss.
• The FS-200-W is not intended for use in explosive environments.
4"
5"
6"
"
3"
33
51
85
120
*
*
22
38
75
*
100
*
90
110
170
240
*
*
*
*
85
100
155
220
*
*
*
*
Dimensions
IS-FS-200-W

Advertisement

loading

Summary of Contents for Watts FS-200-W

  • Page 1 Dimensions Flow Switch Location The preferred installation of the FS-200-W is in a horizontal pipe with a straight run of at least 5 pipe diameters on each side of the paddle (Figure 1). There should be no restrictions from elbows, valves, orifices, etc. Refer to Table 1 below for flow rates.
  • Page 2 For more information: www.watts.com/prop65 Limited Warranty: Watts Regulator Co. (the “Company”) warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of original shipment. In the event of such defects within the warranty period, the Company will, at its option, replace or recondition the product without charge.
  • Page 3 Il est destiné à être utilisé dans des applications impliquant de l'eau et ne doit • Le FS-200-W n'est pas destiné à être utilisé dans des pas être utilisé avec des liquides dangereux ou corrosifs.
  • Page 4 (voir le tableau des débits (Tableau 1)) Garantie limitée : Watts Regulator Co. (la « Société ») garantit que chacun de ses produits est exempt de vice de matériau et de fabrication dans des conditions normales d’utilisation, pour une période d’un an à compter de la date d’expédition d’origine.