Download Print this page
Watts ENWARE SP010 Installation And Maintenance Instructions
Watts ENWARE SP010 Installation And Maintenance Instructions

Watts ENWARE SP010 Installation And Maintenance Instructions

Classic hob mounted spout

Advertisement

Quick Links

Classic Hob Mounted Spout
Installation and Maintenance Instructions
SP010
SP026
SP010R
SP026R
SP011
SP028
SP012
SP190
SP020
FS010
SP021
technical data
Working Pressure Range
Maximum Working
Temperature
Flow Rate
Inlet Connection
Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA) and AS/NZS3500.
Installations not complying with PCA and AS/NZS 3500 may void the product and performance warranty provisions.
Reference should also be made to the Australasian Health Facility Guidelines (AHFG), ABCB and Local Government
regulations when considering the choice of, and the installation of these products.
This product must be installed and commissioned by a qualified plumber.
For use with potable water only.
NOTE: Enware Australia advises:
1. Due to ongoing Research and Development, specifications may change without notice.
2. Component specifications may change on some export models.
I00579_05 Feb 2024
1300 369 273 | info@enware.com.au | enware.com.au
Min 50 kPa
Max 500 kPa
70°C
8 L/min (WELS 3 Star)
6 L/min (WELS 5 Star)
1/2" BSP (15mm)

Advertisement

loading
Need help?

Need help?

Do you have a question about the ENWARE SP010 and is the answer not in the manual?

Questions and answers

Summary of Contents for Watts ENWARE SP010

  • Page 1 Classic Hob Mounted Spout Installation and Maintenance Instructions SP010 SP026 SP010R SP026R SP011 SP028 SP012 SP190 SP020 FS010 SP021 technical data Working Pressure Range Min 50 kPa Max 500 kPa Maximum Working 70°C Temperature Flow Rate 8 L/min (WELS 3 Star) 6 L/min (WELS 5 Star) Inlet Connection 1/2”...
  • Page 2 installation 22 - 25 • Ensure all supply lines are flushed thoroughly to remove debris prior to the installation of this product. Strainers (40 mesh) are recommended if debris is an ongoing problem. • A pressure reduction valve may be required to comply with IMAGE 01 INSTALLATION DETAIL the recommended maximum supply pressure requirements.
  • Page 3 maintenance CLEANING Enware products should be cleaned with a soft damp cloth using only mild liquid detergent or soap and water. Do not use cleaning agents containing a corrosive acid, scouring agent or solvent chemicals. Do not use cream cleaners, as they are abrasive. Use of unsuitable cleaning agents may damage the surface.
  • Page 4 - WATTS AUSTRALIA EFFECTIVE FROM 20 November 2023 3. Our responsibilities This Warranty Statement applies to products supplied by Australian Valve (a) In the event that the Supplier is reasonably satisfied that there is a Group Pty Ltd (ACN 068 227 270) (AVG) or Enware Pty Ltd (ACN 662...

This manual is also suitable for:

Enware sp010rEnware sp011Enware sp012Enware sp020Enware sp021Enware sp026 ... Show all