Cleaning Detergent Siphoning Tube
If you used the detergent siphoning tube, you must flush it
with clean water before stopping the engine.
1.
Place chemical injection siphon/filter in a bucket full of
clean water.
2.
Attach black low pressure spray tip.
3.
Flush for 1-2 minutes.
4.
Shut off engine.
IMPORTANT: Simply shutting OFF engine will not
release pressure in the system. When the engine has
shut down, squeeze the trigger on the spray gun to
relieve the pressure in the hose.
Pump Maintenance
Changing Pump Oil
Change oil every 50 hours or once yearly, whichever
occurs first.
NOTE: Purchase a premeasured bottle of pump oil, item
number 190585GS, by contacting nearest authorized
service center.
Change pump oil as follows:
1.
Drain engine oil and fuel from pressure washer.
2.
Use 8mm allen wrench to remove black oil cap from
pump. It's found between high pressure outlet and
garden hose inlet (Figure 15).
Figure 15 - Changing Pump Oil
Generac Portable Products 2650 PSI Pressure Washer
3.
4.
5.
6.
ENGINE MAINTENANCE
See the engine owner's manual for instructions on how to
properly maintain the engine.
Oil Cap
14
Tilt pressure washer to drain oil into an approved
container until it drips slowly from the pump.
Tilt pressure washer in opposite direction and empty
premeasured pump oil bottle into same opening (a
small funnel may be helpful).
Install black oil cap on pump and tighten firmly.
Set pressure washer in upright position. Add fuel and
engine oil.
CAUTION
Avoid prolonged or repeated skin contact with used
motor oil.
• Used motor oil has been shown to cause skin cancer in
certain laboratory animals.
• Thoroughly wash exposed areas with soap and water.
KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.