MKS PSR1A User Manual

MKS PSR1A User Manual

Power supply and pressure/flow readout

Advertisement

User Manual
PSR1A/PSR4A POWER SUPPLY AND
PRESSURE/FLOW READOUT
SINGLE / MULTI-CHANNEL POWER SUPPLY / READOUT
2 TECH DRIVE SUITE 201
ANDOVER, MA 02810 USA
(978) 645.5500
MKS P/N 20068380-001 Rev A
FAX: (978) 557.5100
E-MAIL: MKS@MKSINST.COM
WWW.MKSINST.COM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSR1A and is the answer not in the manual?

Questions and answers

Summary of Contents for MKS PSR1A

  • Page 1 MKS P/N 20068380-001 Rev A User Manual PSR1A/PSR4A POWER SUPPLY AND PRESSURE/FLOW READOUT SINGLE / MULTI-CHANNEL POWER SUPPLY / READOUT 2 TECH DRIVE SUITE 201 FAX: (978) 557.5100 E-MAIL: MKS@MKSINST.COM ANDOVER, MA 02810 USA WWW.MKSINST.COM (978) 645.5500...
  • Page 2 MKS Instruments, Inc. Printed in the United States of America Baratron® is a registered trademark of MKS Instruments, Inc. or a subsidiary of MKS Instruments, Inc. All other product names herein are used for identification purposes only and are recognized as properties (including trademarks, registered trademarks, and referenced copyrighted materials) of their respective companies.
  • Page 3: Table Of Contents

    Product Description ........................10 How the PSR1A/PSR4A Works ....................10 Abbreviations Used in this Manual ....................10 4 Installation ............................11 Unpacking the PSR1A or PSR4A Power Supply and Readout ..........11 4.1.1 Opening the Package ......................11 Product Location and Requirements ..................11 Dimensions ..........................12 Setup ............................13 4.4.1 Panel Mounting ........................13...
  • Page 4: List Of Figures

    Figure 2: Panel Mounting ........................13 Figure 3: Panel Cutout Dimensions ......................14 Figure 4: Tabletop Mounting ........................14 Figure 5: Rear Panel Connectors PSR1A and PSR4A ................15 Figure 6: Front Panel Buttons ........................18 Figure 7: Home Screen ...........................19 Figure 8: Startup Menu ..........................20 Figure 9: Configuration Menu ........................20...
  • Page 5: Warranty

    1 Warranty Service and Warranty Guidelines Some minor problems are readily corrected on site. If the product requires service, contact the MKS Technical Support Department at +1-833-986-1686. If the product must be returned to the factory for service, request a Return Material Authorization (RMA) from MKS. Do not return products without first obtaining an RMA.
  • Page 6: Safety Information

    IEC 417, No. 5017 IEC 417, No. 5019 Frame or Chassis Equipotentiality Direct Current Alternating Current IEC 417, No. 5020 IEC 417, No. 5021 IEC 417, No. 5031 IEC 417, No. 5032 6 | PSR1A/PSR4A POWER SUPPLY AND PRESSURE/FLOW READOUT...
  • Page 7: Safety Procedures And Precautions

    DO NOT SUBSTITUTE PARTS OR MODIFY INSTRUMENT Do not install substitute parts or perform any unauthorized modification to the instrument. Return the instrument to an MKS Calibration and Service Center for service and repair to ensure that all safety features are maintained.
  • Page 8 DO NOT SUBSTITUTE PARTS OR MODIFY THE INSTRUMENT Do not install substitute parts or perform any unauthorized modification to the instrument. Return the instrument to an MKS Calibration and Service Center for service and repair to ensure that all safety features are maintained.
  • Page 9 Only use a detachable cord set with conductors having a cross-sectional area equal to or greater than 0.75 mm2. The power cable should be approved by a qualified agency such as VDE, Semko, or SEV. 9 | PSR1A/PSR4A POWER SUPPLY AND PRESSURE/FLOW READOUT...
  • Page 10: General Information And Product Overview

    How the PSR1A/PSR4A Works The PSR1A and PSR4A are microprocessor based, with no power or selection switches, jumpers, or potentiometers. Universal input and output signals support a wide range of measurements for flow and pressure control and measurement, and services include quantity accumulation, rate measurements, and scalar measurements.
  • Page 11: Installation

    Unpacking the PSR1A or PSR4A Power Supply and Readout MKS has carefully packed the PSR1A or PSR4A unit so that it will reach you in perfect operating order. Upon receiving the unit, however, you should check for defects, cracks, broken connectors, etc., to be certain that damage has not occurred during shipment.
  • Page 12: Dimensions

    USER MANUAL MKS P/N 20068380-001 Rev A Dimensions All dimensions are listed in inches with millimeters referenced in NOTE parentheses. Figure 1: Dimensions, PSR1A and PSR4A 12 | PSR1A/PSR4A POWER SUPPLY AND PRESSURE/FLOW READOUT...
  • Page 13: Setup

    4.4.1 Panel Mounting The PSR1A/PSR4A comes standard with hardware for panel mounting and are available with brackets to assemble for desktop use. Use the two enclosed angle brackets and #6-32 screws to secure the unit to a panel cutout. Be sure to not overtighten the screws as this may damage the threaded holes in the PSR1A/PSR4A.
  • Page 14: Tabletop Mounting

    USER MANUAL MKS P/N 20068380-001 Rev A Figure 3: Panel Cutout Dimensions 4.4.2 Tabletop Mounting The PSR1A/PSR4A also comes with tabletop mounting bracketry and hardware, as shown below. Figure 4: Tabletop Mounting 14 | PSR1A/PSR4A POWER SUPPLY AND PRESSURE/FLOW READOUT...
  • Page 15: Rear Panel Connections

    USER MANUAL MKS P/N 20068380-001 Rev A Rear Panel Connections The rear panel of the PSR1A/PSR4A has connections for power, analog and serial communication, and LAN ports. Figure 5: Rear Panel Connectors PSR1A and PSR4A 15 | PSR1A/PSR4A POWER SUPPLY AND PRESSURE/FLOW READOUT...
  • Page 16: Rear Panel Connections

    12-24 VDC round plug – this plug accepts the enclosed 85-265 VAC power supply, allowing the user to utilize the PSR1A/PSR4A with AC voltage from standard wall outlets. • Serial Port – this 9-pin D connector allows the user to control the PSR1A/PSR4A via RS-232. The connections of this connector are: Signal •...
  • Page 17 +12 – 24 VDC power supply – the included power supply assembly plugs into this rear panel connector, allowing the user to utilize the PSR1A/PSR4A with AC voltage from standard wall outlets. Power options include US, EU, Japan, and UK style, and are specified at order.
  • Page 18: Operation

    MKS P/N 20068380-001 Rev A 5 Operation Buttons The front panel of the PSR1A/PSR4A has four buttons in a central cluster and two buttons on either side of the cluster, as shown below. Figure 6: Front Panel Buttons The central cluster consists of a green SET button, and three directional arrow buttons, UP, DOWN, and BACK.
  • Page 19: Home Screen

    USER MANUAL MKS P/N 20068380-001 Rev A Home Screen When the PSR1A/PSR4A is powered up, a home screen is displayed as shown below. Figure 7: Home Screen Startup Menu After a short time, the screen will change to indicate the status of each channel as shown below in Figure 8.
  • Page 20: Configuration Menus

    PV or SP value is currently displayed. Toggle up or down and press SELECT | PROG to change the values displayed on the home screen. Press HOME | START to return to the home screen. 20 | PSR1A/PSR4A POWER SUPPLY AND PRESSURE/FLOW READOUT...
  • Page 21: Instrument Configuration Menu

    Toggle up or down to reach the desired setting on the menu list, and press SET to display options for that parameter. Be aware that MKS does not offer devices to measure or control many of these parameters, and care must be taken when using any devices for compatibility.
  • Page 22 For time dependent processes such as flow rate, time units are selectable from day, hrs, min, sec, or None (for static units of measure). Decimal Each channel of the PSR1A/PSR4A can display PV and SP with three significant places and a decimal point in any of four positions – xxx, xx.x, x.xx, .or .xxx Gas Fact For mass flow controllers and meters being operated with a material other than the active or calibration gas, you can enter a GCF (gas correction factor).
  • Page 23 SP Source This control enables selection of the source from which setpoints may be entered as either Keypad or Serial. When set for Serial, changing a setpoint using the keypad is prohibited. 23 | PSR1A/PSR4A POWER SUPPLY AND PRESSURE/FLOW READOUT...