Masimo stork vitals+ User Manual
Masimo stork vitals+ User Manual

Masimo stork vitals+ User Manual

Smart home baby monitoring system
Hide thumbs Also See for stork vitals+:

Advertisement

Quick Links

User's Manual
stork
vitals+
Smart Home Baby Monitoring System

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the stork vitals+ and is the answer not in the manual?

Questions and answers

Summary of Contents for Masimo stork vitals+

  • Page 1 User's Manual stork vitals+ Smart Home Baby Monitoring System...
  • Page 3 Masimo® and ® are federally registered trademarks of Masimo Corporation. Stork™ is a trademark of Masimo Corporation. Google Play and the Google Play logo are trademarks of Google LLC. App Store and App Store logo are registered trademarks of Apple Inc. The Bluetooth word mark and logo are registered trademarks owned by Bluetooth SIG, Inc.
  • Page 4: Table Of Contents

    Advanced Use .................... 34 Notifications .................... 34 Sensor Battery Charge Status ................ 36 Live Controls ................... 36 Side Menu ....................37 Bottom Menu ................... 39 How to Turn Stork On and Off ............... 40 Troubleshooting ..................41 Appendix ....................44 Masimo Corporation www.masimo.com...
  • Page 5: About This Manual

    Service and Maintenance ................57 About This Manual This Manual provides an overview of the Masimo Stork and how to set up and use the system. You must read and understand the warnings and precautions to help ensure safe and effective use of the Stork System. See on page 7.
  • Page 6: Glossary

    Product Description Masimo Stork™ is a smart home baby monitoring system designed for parents to monitor baby at home. Masimo Stork consists of a sensor, boot, and camera that used with a cloud and smart device app. The Stork smart home baby monitoring system consists of the following: •...
  • Page 7: Who The Device Is Intended To Be Used On (Indications For Use)

    0 to 18 months of age and between 6 to 30 lbs. The Masimo Stork™ is also indicated for continuous skin temperature measurements of infants and neonates who are 0 to 18 months and between 6 to 30 lbs.
  • Page 8 To avoid skin injury, consider alternating feet after more than 8 hrs of WARNING: continuous use. Only use Masimo authorized devices with Stork. Using unauthorized devices WARNING: with Stork may result in damage to the device and/or patient injury. Remove Stork Boot and Sensor before placing baby in water and dry baby's CAUTION: foot completely before placing sensor and boot back on.
  • Page 9: Performance Warnings

    Keep the Stork Camera plugged in while in use. Loss of power may limit the CAUTION: notifications available. Do not connect the Stork Camera to an electrical outlet controlled by a wall CAUTION: switch or dimmer. Someone may accidentally turn the power off to your Stork Camera. Masimo Corporation www.masimo.com...
  • Page 10 The temperature readings may not be accurate if there is: CAUTION: • Obstructed access to the skin surface (e.g., clothing, perspiration, excess oil or lotions). • An obstructed temperature sensor. Masimo Corporation www.masimo.com...
  • Page 11: Wireless

    To ensure security and prevent tampering of your smart phone, while using CAUTION: Stork: • Smart phones should be located with the responsible users. • Smart phones should not be left unattended. Masimo Corporation www.masimo.com...
  • Page 12: Cleaning And Service

    CAUTION: by any method to prevent damage to the device. Radio and Disposal Compliance Changes or modifications not approved by Masimo can void the user’s WARNING: authority to operate the equipment. The frequency bands of this device (2.4 GHz) are only for indoor use in WARNING: accordance with international telecommunication requirements.
  • Page 13: Risks And Benefits

    However, these risks have been mitigated through the design and testing of Stork. • As with all devices with small parts, there is always a risk of a child swallowing a component or choking. Keep small parts away from small children to prevent swallowing or choking. Masimo Corporation www.masimo.com...
  • Page 14: Benefits Of Stork

    Stork uses the same proven pulse oximetry used in hospitals shown to have fewer false alarms compared to other brand technology. • Stork allows for the storage and review of your blood oxygen level as you go about your normal activities, including sleep. Barker S.J. Anesth Analg. 2002 Oct;95(4):967-72. Masimo Corporation www.masimo.com...
  • Page 15: Meet The Stork System

    Stork Sensor 5W AC power adapter • Stork Camera 12W AC power adapter • Stork Sensor charge cable and cable clip • Stork Camera power cable and cable covers • Stork Camera wall mounting bracket (and hardware) Masimo Corporation www.masimo.com...
  • Page 16: Components Of Stork

    Located on the bottom of the camera. Power is provided by the AC adapter and the power cable. The cable is routed through the opening in camera base. A hole to access the factory reset button is located on the bottom of the camera. Note: Masimo Corporation www.masimo.com...
  • Page 17 Displays the sensor status. See on page 44. Sensor Sta tus Light Light 5 Charging Charge the sensor battery using the charging cable and AC power Contacts adapter. See on page 26. C ha rging the Stork Sensor Masimo Corporation www.masimo.com...
  • Page 18 Do not use the boot if it appears to be damaged. Damage to the boot may WARNING: result in poor performance and/or injury. 1 Stork Boot Secures the Stork Sensor to the baby's foot. 2 Strap Attaches to the boot. 3 Stork Sensor Pocket The sensor is placed into this pocket. Masimo Corporation www.masimo.com...
  • Page 19: Stork Grows With Your Baby

    Limit tracking of baby's vital signs data to while baby is sleeping. baby is crawling, standing, or walking, remove the boot when awake or active. Consult with the baby's healthcare provider if they have concerns regarding sleep Note: interruptions related to the device. Masimo Corporation www.masimo.com...
  • Page 20: Why Is My Stork Vitals Alarming

    • Check for blanket or soft bumpers of the crib covering the baby’s mouth and nose. If you can, clear their nose and mouth. C a ll 911, if y ou think your ba by needs help. Masimo Corporation www.masimo.com...
  • Page 21: Basic Setup And Use Of Stork

    Pair the sensor using the app. • Insert the sensor into the Stork Boot. • Secure the boot to the foot. 3. Confirm the correct setup • After the Boot is attached to the foot, open the app. Masimo Corporation www.masimo.com...
  • Page 22: Step 1: Smart Phone Setup

    Follow the app instructions to and set up a . Enter the requested information about the baby when prompted. If you need to make changes to the baby profile or create a baby profile, see Note: Side on page 37. Menu Masimo Corporation www.masimo.com...
  • Page 23: Step 2: Setting Up The Stork System

    1. Plug the power cable into the camera (A), the power cable into the 12W AC power adapter and plug the power adapter into a wall socket (C). Note: The camera Indicator is white when powered on. See Camera Status Light on page 51. Masimo Corporation www.masimo.com...
  • Page 24 We recommend you leave a 1-2 ft gap between crib side and wall on which the camera is mounted. No matter the camera location, the camera can be adjusted for the perfect view of the baby. Masimo Corporation www.masimo.com...
  • Page 25 Make sure it is level and the 4 hook s a re fa c ing up, then mark the locations of the screw holes. 3. Drill the 2 marked locations using a 1/4" (6.35 mm) drill bit. 4. Gently tap the two wall anchors into the holes until they are flush with the wall. Masimo Corporation www.masimo.com...
  • Page 26 Pair the sensor using the Stork app. Charging the Stork Sensor 1. To charge the Stork Sensor, plug the charge cable into the 5W AC power adapter and plug the power adapter into a wall socket (B). Masimo Corporation www.masimo.com...
  • Page 27 Select the proper Stork Boot and strap size. • Attach the Stork Sensor to the boot. • Place the boot on the foot. The Stork Boot should not be used while the baby is standing or walking. Note: Masimo Corporation www.masimo.com...
  • Page 28 To remove the strap, simply slide back off. 2. Insert the sensor into the boot at an angle, toe end first, with the Masimo logo facing down. 3. Press down to secure the sensor. The sensor should sit flush in the boot.
  • Page 29 Change the straps as needed to fit your baby. When sizing the straps for proper fit, for example, a small newborn will most likely require the Size 2 strap at the ankle and the Size 1 strap at the sensor. Masimo Corporation www.masimo.com...
  • Page 30 Spot clean as necessary and clean both boot and straps daily or before each use or when they appear soiled or dirty. See cleaning instructions for more details. Do not apply the boot on feet that have redness or irritation. Skin conditions CAUTION: may affect the ability to comfortably wear the boot. Masimo Corporation www.masimo.com...
  • Page 31: Step 3: View Live Data

    Swipe up to view health data 6 Health Data Dashboard - readings. See on page 31. Hea lth Da ta Da shboa rd Shortcuts to additional app functions and 7 Bottom Menu - features. See on page 39. Bottom Menu Masimo Corporation www.masimo.com...
  • Page 32 It is important to make sure your sensor is properly applied. The following items on the Data Dashboard can help identify good sensor placement: • Oxygen saturation is displayed • Pulse Rate is displayed • Temperature is displayed Masimo Corporation www.masimo.com...
  • Page 33 2 minutes should be checked on immediately. See Why is my Stork Vitals Alarming. An audio alarm can only be silenced for 2 minutes at a time. After 2 minutes, the alarm will sound again. Masimo Corporation www.masimo.com...
  • Page 34: Advanced Use

    Alarms or Notification tab. Touch an alarm or notification to view additional information and acknowledge. Any "next steps" to address the alarm or notification may also be shown (when available). Alarms Examples of alarms include: - When a parameter goes above or below the set alarm limits. Parameter Alarms Masimo Corporation www.masimo.com...
  • Page 35 Medium and high priority notifications are available. See C a mera Sta tus Light page 51. When a low or medium priority notification is present, the camera status light flashes Yellow, and in some cases, an audible notification sounds. When a high priority Masimo Corporation www.masimo.com...
  • Page 36: Sensor Battery Charge Status

    The Stork Sensor battery is low (low priority notification) or depleted (medium priority notification). • The Masimo Cloud server is disconnected from the Stork System. Examples of high priority notifications: • The Stork Sensor has come off or has been removed from the baby while measuring the baby's health data.
  • Page 37: Side Menu

    Baby Profile Management Baby Profile From the screen, the first and last name, biological sex, birthday, weight and length can be updated. Masimo Corporation www.masimo.com...
  • Page 38 Select the add device "+" button at the bottom of the screen and select Add a Stork device - the Stork device to add. Follow the in-app instructions to add the device. Make sure you have the device you want to add with you for ease of adding to Stork. Masimo Corporation www.masimo.com...
  • Page 39: Bottom Menu

    Review history data recorded by Stork. See 2 History - History on page 40. Access to view other Stork Systems that have been 3 Sharing - shared with you or share your system with other caregivers. See on page 40. Sha ring Masimo Corporation www.masimo.com...
  • Page 40: How To Turn Stork On And Off

    Once the Stork System is connected to power during setup, and the sensor is charged, the system is on. Neither the Stork Camera nor Stork Sensor have an On/Off switch or controls to turn On or Off. To turn the system Off: 1. Unplug the camera power adapter from the wall socket. Masimo Corporation www.masimo.com...
  • Page 41: Troubleshooting

    Boot and the Boot is properly placed on the foot. • If you still experience issues, please contact Masimo Customer Support. See Customer Support on page 57. Sensor is not working. Replace sensor. "Replace your sensor"...
  • Page 42 • Update the smart phone software. Refer to the Bluetooth Low Energy (BLE). smart phone's Operator's Manual or Directions For Use. • Contact Masimo Customer Support. See Customer Support on page 57. Stork Camera does • Stork Camera is not connected •...
  • Page 43 • Check network settings and availability. May have • Sensor is not connected to the to call network provider for further assistance. Stork Camera. • Contact Masimo Customer Support. See Customer • No previous sessions have been Support on page 57. recorded.
  • Page 44: Appendix

    Solid White Sensor battery is fully charged Blinking Red Sensor battery is very low/depleted Solid or Blinking Red in a pattern to indicate a Sensor has a problem (non-battery related). Customer number code Support on page 57 Masimo Corporation www.masimo.com...
  • Page 45 Low Perfusion [4] Infants, Neonates 3 bpm accuracy is a statistical calculation of the difference between device measurements and reference measurements. Approximately two-thirds of the device measurements fell within +/- A of the reference measurements in a controlled study. Masimo Corporation www.masimo.com...
  • Page 46 The tables below provide the (Accuracy Root Mean Square) values for the Stork as compared to Masimo RD SET Adhesive sensors under no motion clinical testing. A total of 30 subjects, 14 dark skinned and 16 light skinned, were tested.
  • Page 47 (up to 7 minutes). Accuracy Temperature Laboratory 25°C to 43°C (77°F to 109.4°F) ±0.3°C (±0.54 °F) Application Site Foot Electrical Battery - Stork Sensor Type Li-ion Rechargeable Run Time 16 hours [5] Charging Time 2 Hours [6] Masimo Corporation www.masimo.com...
  • Page 48 Suitable for use in all establishments, including domestic environments and (Conducted) Class B those directly connected to the public low-voltage power supply network CISPR 11 that supplies buildings used for domestic purposes. Harmonic Emissions Class A IEC 61000-3-2 Masimo Corporation www.masimo.com...
  • Page 49 45°, 90°, 135°, 135°, 180°, 225°, IEC 61000-4-11 180°, 225°, 270°, and 315°; 270°, and 0% UT 1 cycle, 315°; and 70% UT 25/30 0% UT 1 cycle, cycles at 0° and 70% UT 25/30 cycles at 0° Masimo Corporation www.masimo.com...
  • Page 50 1900; DECT; LTE Band 1, 3. 4. modulation 1990 1970 35: UMTS 217 Hz Pulse 2400- Bluetooth, WLAN, 802.11 2450 modulation 2570 b/g/n, RFID 2450, LTE Band 7 217 Hz 5240 Pulse 5100- 5500 WLAN 802.11 a/n modulation 5800 5785 217 Hz Masimo Corporation www.masimo.com...
  • Page 51 The sensor is not actively monitoring. Solid White The sensor is actively monitoring with a successful connection to the Masimo Cloud. Blinking Green The camera is ready for pairing to the smart phone/Stork app or to be connected to the wireless network.
  • Page 52 16 degrees Wireless Specifications Communication (Bluetooth) - Stork Camera Type Bluetooth Frequency 2402-2480 MHz Classification of Output Power Rating Conducted Max. Peak Output Power 4.28 dBm Output Power Type Fixed at the Factory Modulation Types DH5, 2DH5, 3DH5 Masimo Corporation www.masimo.com...
  • Page 53 802.11an: OFDM 802.11ac: OFDM Modulation Signals Analog and Digital Available Data Rates 802.11b - 1, 2, 5.5, 11 Mbps 802.11g - 6, 9, 12, 18, 24, 36, 48, 54 Mbps 802.11n- MCS0 – MCS7 802.11ac- MCS0 – MCS9 Masimo Corporation www.masimo.com...
  • Page 54 Degree of Protection against Type BF-Applied Part Electrical Shock Protection against harm from Water IP44 - Protection from solid bodies larger than 1 millimeter and protection and Particulate Matter against small splashes of water coming from all directions. Masimo Corporation www.masimo.com...
  • Page 55 Identifies unit has been registered as a radio device Non-Sterile Recyclable Not made with natural rubber latex Product contains no PVC (polyvinyl chloride) Caution material Date of manufacture Warning YYYY-MM-DD Manufacturer Catalog number (model number) Serial number Masimo reference number Storage temperature range AC current Masimo Corporation www.masimo.com...
  • Page 56 0.02% for the simulated saturation range of 70% to 100%. [4] The Masimo Stork has been validated for pulse rate accuracy for the range of 25-240 bpm in bench top testing against a simulator and Masimo’s simulator with signal strengths of greater than 0.02%.
  • Page 57 The Stork Camera does not require cleaning with the exception of wiping the surface Note: with a damp cloth. Customer Support For product support, along with troubleshooting for your Stork product, please go to the Stork Support page www.masimostork.com/en-us/support/contact-us.html. Masimo Corporation www.masimo.com...
  • Page 58 Stork Vitals+ Appendix For warranty information for your Stork product, please go to the Stork warranty page www.masimostork.com/en-us/support/warranty.html. Masimo Corporation www.masimo.com...
  • Page 60 304200/LAB-11858B-0524...

This manual is also suitable for:

Stork vitals

Table of Contents