Page 3
General knowledge of pulse oximetry and an understanding of the features and functions of MightySat Rx are prerequisites for its proper use. Do not operate MightySat Rx without completely reading and understanding these instructions.
Using the Touchpad ----------------------------------------------------------------------------------- 22 Navigating the Menu ---------------------------------------------------------------------------------- 23 Connecting to a Smart Device via Bluetooth (Optional) ---------------------------------------- 24 Bluetooth Connection Overview --------------------------------------------------------------------- 24 Cleaning, Disinfecting, and Service --------------------------------------------------------------------- 25 Cleaning and Disinfecting MightySat Rx ----------------------------------------------------------- 25 Service --------------------------------------------------------------------------------------------------- 26 www.masimo.com Masimo...
Do not operate the MightySat™ Rx Fingertip Pulse Oximeter without completely reading and understanding the instructions. Always use the MightySat Rx precisely in accordance with the directions in this manual, including site selection and sensor placement. Failure to follow all of the directions in this manual could lead to inaccurate measurements.
The MightySat™ Rx Fingertip Pulse Oximeter is indicated for the noninvasive spot checking of functional oxygen saturation of arterial hemoglobin (SpO2) and pulse rate (PR). The Masimo MightySat™ Rx Fingertip Pulse Oximeter is indicated for use with adult and pediatric patients during both no motion and motion conditions, and for patients who are well or poorly perfused in hospitals, hospital-type facilities, and mobile environments.
• WARNING: Only use the MightySat Rx to the secure it to the finger. Excessive pressure to a finger can cause skin damage. • WARNING: Check the sensor site every hour to ensure adequate circulation, skin integrity, and sensor alignment.
WARNING: Do not use MightySat Rx for continuous monitoring. It is intended for spot-check use only. No alarms are provided to support continuous monitoring. • WARNING: Do not use MightySat Rx if it appears or is suspected to be damaged. Damage to internal parts can result in no or inaccurate readings. •...
Page 13
Note: The MightySat Rx display may be difficult to view when exposed to direct sunlight or bright lights. • Note: Do not assess the accuracy of the MightySat Rx using a functional tester. A functional tester should only be used to check if a unit is working properly. •...
WARNING: Properly use and dispose of Alkaline batteries or they may leak or explode. • WARNING: Remove alkaline batteries when the MightySat Rx will not be in use for more than 30 days to avoid damage to the device due to batteries that may leak. •...
CAUTION: This device has not been evaluated for use in aircrafts. • Note: When using MightySat Rx with a device with wireless features, consideration should be taken to local government frequency allocations and technical parameters to minimize the possibility of interference to/from other wireless devices.
Masimo products. Signal Extraction Technology® (SET®) Masimo Signal Extraction Technology's signal processing differs from that of conventional pulse oximeters. Conventional pulse oximeters assume that arterial blood is the only blood moving (pulsating) in the measurement site. During patient motion, however, the venous...
SpO2 and pulse rate. Functional Oxygen Saturation (SpO2) The MightySat Rx is calibrated to measure and display functional oxygen saturation (SpO2): the amount of oxyhemoglobin expressed as a percentage of the hemoglobin that is available to transport oxygen.
MightySat Rx Technology Overview Citations for Pleth Variability Index (PVI) Cannesson M., Desebbe O., Rosamel P., Delannoy B., Robin J., Bastien O., Lehot J.J. Pleth Variability Index to Monitor the Respiratory Variations in the Pulse Oximeter Plethysmographic Waveform Amplitude and Predict Fluid Responsiveness in the Operating Theatre.
Operation MightySat Rx Features ID Description Function Enclosure Clip Clip provided for ease of lanyard attachment. 2 Bluetooth Indicates when Bluetooth LE is enabled on the device. Indicator (Optional) 3 Battery Status Indicates the remaining relative life of the battery.
To take readings with the MightySat Rx, follow the instruction below: Note: Before use, ensure batteries are correctly installed in the MightySat Rx. To open the MightySat Rx, squeeze the back portion of the device as shown in the image above.
The internal spring provides the correct pressure; additional pressure may cause inaccurate readings. Turning off MightySat Rx The MightySat Rx turns off automatically after removing the finger from the device in the absence of device interaction or connection to a smart device. www.masimo.com...
MightySat Rx Operation Using the Touchpad The Touchpad on MightySat Rx device is located below the display screen. Note: The display is not a touch screen. Action Description Function Touch Tap and release. Action will be Select a menu item or action.
MightySat Rx Operation Navigating the Menu From the Main Screen, press and hold the Touchpad to access the Main Menu. Use the Touchpad Swipe gesture to scroll through the Main Menu Options. Use the Touch gesture to select the Main Menu Option. Use the same gestures to adjust settings.
MightySat Rx Operation Connecting to a Smart Device via Bluetooth (Optional) Note: Bluetooth LE is an optional feature available on specific versions of MightySat Rx for use with compatible smart devices. For a full list of compatible smart devices, see www.masimoprofessionalhealth.com.
12 in this manual. WARNING: Before cleaning, make sure the device is off and is not applied to a finger. CAUTION: Thoroughly clean and low level disinfect the MightySat Rx before applying it to on a new patient. Note: Before cleaning, remove the batteries and make sure the battery cover is re-attached correctly.
Cleaning, Disinfecting, and Service Service WARNING: Do not attempt to repair the MightySat Rx as this may cause damage to the device and prevent it from operating properly. If the device does not appear to be operating correctly, see Troubleshooting on page 26 section in this manual.
Smart device Check that MightySat Rx is damaged connected to the correct smart device Contact Masimo Technical Services Product Support For additional help, contact Masimo Technical Services at (949) 297-7498. Local contact information can be found at http://service.masimo.com. www.masimo.com Masimo...
48 months from the original date the Product was obtained by the end-user purchaser. Masimo’s sole obligation under this warranty is the repair or replacement, at its option, of any defective Product or software media that is covered under the warranty.
Sales & End-User License Agreement This document is a legal agreement between you (“purchaser”) and Masimo Corporation (“Masimo”) for the purchase of this Product (“Product”) and a license in the included or embedded Software (“Software”) except as otherwise expressly agreed in a separate contract for the acquisition of this Product, the following terms are the entire agreement between the parties regarding your purchase of this Product.
Product or the Software on a temporary basis. Purchaser shall not assign or transfer this License, in whole or in part, by operation of law or otherwise without Masimo's prior written consent; except that the Software and all of Purchaser’s rights hereunder shall transfer automatically to any party that legally acquires title to the Product with which this Software is included.
Pleth Variability Index (PVI) 0% to 100% The emitted wavelengths range from 600 nm to 1000 nm and the peak optical power is less than 15 mW. Information about the wavelength range can be especially useful to clinicians. www.masimo.com Masimo...
SpO2 Performance Specifications Table below provides Arms (Accuracy Root Mean Square) values measured using the ® MightySat Rx with Masimo SET Oximetry Technology in a clinical study under no motion conditions. The below Bland-Altman plot represents the correlation of the (SpO2 + SaO2)/2 versus (SpO2 - SaO2) under no motion with an upper 95% and lower 95% limits of agreement.
MightySat Rx Specifications Battery Life Item Description Operating 1.5 Volt AAA Battery (2) Battery Life *Approximately 1800 spot checks *Note: Based upon 15 hours of operation with screen brightness set to 50% a spot check of 30 seconds. Physical Characteristics...
MightySat Rx Specifications Radio Compliance Radio Modes Bluetooth LE FCC ID: VKF-MSAT01A FCC parts 15.207 and 15.247 Canada IC-7362A-MSAT01A RSS-210 Europe EN 300 328 EN 301 489-17 Environment Item Description Operating Temperature Range 5°C to 40°C Operating Humidity 10% to 95% RH Storage/Transport Temperature -40°C to 70°C...
Specifications Citations The Masimo SET® Technology used in the MightySat™ Rx Fingertip Pulse Oximeter has been validated for no motion accuracy in human blood studies on healthy adult male and female volunteers with light to dark pigmented skin in induced hypoxia studies in the range of 70%-100% SpO2 against a laboratory co-oximeter.
MightySat Rx Specifications Symbols The following symbols may be found on the product or packaging. Symbol Definition Symbol Definition Protection from ingress of particulates > Follow Instructions IP23 than 12.5 mm and ingress from spraying for Use water ETL Intertek certification. Conforms to...
MightySat Rx Specifications Guidance and Manufacturer's Declaration - Electromagnetic Emissions Guidance and Manufacturer's Declarations - Electromagnetic Emissions The ME Equipment is intended for use in the electromagnetic environment specified below. The customer or the user of the ME Equipment should assure that it is used in such an environment.
MightySat Rx Specifications Guidance and Manufacturer's Declaration - Electromagnetic Immunity Guidance and Manufacturer's Declaration - Electromagnetic Immunity The ME Equipment is intended for use in the electromagnetic environment specified below. The customer or the user of the ME Equipment should assure that it is used in such an environment.
Page 42
MightySat Rx Specifications Guidance and Manufacturer's Declaration - Electromagnetic Immunity Portable and mobile RF communications equipment should be used no closer to any part of the ME Equipment, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.
Page 43
MightySat Rx Specifications Guidance and Manufacturer's Declaration - Electromagnetic Immunity Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered.
MightySat Rx Specifications Recommended Separation Distances Recommended Separation Distance Between Portable and Mobile RF Communication Equipment and the ME Equipment The ME Equipment is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the ME Equipment can help...
Citations • 36 Citations for Pleth Variability Index (PVI) • 17 Indications for Use • 7 Cleaning and Disinfecting MightySat Rx • Installing the AAA Batteries • 20, 26 Cleaning, Disinfecting, and Service • 12, Cleaning, Disinfecting, Service Warnings Limitation of Warranty • 29 and Cautions •...
Page 46
Successful Monitoring for SpO2, PR and PI • 16 Symbols • 37 Technology Overview • 15 Troubleshooting • 21, 26 Turning off MightySat Rx • 21 Using MightySat Rx • 20, 26, 27 Using the Touchpad • 19, 22 www.masimo.com Masimo...