Disconnect the spark plug wire and ground it against the engine to prevent unintended starting. Before performing any type of maintenance/service, disengage all controls and stop the engine. Wait until all moving parts have come to a complete stop. Always wear safety glasses during operation or while performing any adjustments or repairs.

This section addresses minor service issues. To locate the nearest Sears Service Center or to schedule service, call the following toll free number: 1-888-331-4569.

Problem Cause Remedy

Engine fails to start

  1. Choke control not in Choke position.
  2. Spark plug wire disconnected.
  3. Faulty spark plug.
  4. Fuel tank empty or stale fuel.
  5. Engine not primed.
  6. Safety key not inserted.
  7. Extension cord not connected (when using electric start button)
  1. Move choke control to Choke position.
  2. Connect wire to spark plug.
  3. Clean, adjust gap, or replace.
  4. Fill tank with clean, fresh gasoline.
  5. Prime engine as instructed in the Operation Section.
  6. Insert safety key fully into the switch.
  7. Connect one end of the extension cord to the electric starter outlet and the other end to a three-prong 120V, grounded, AC outlet.

Engine running erratically/ inconsistent RPM (hunting or surging)

  1. Engine running on choke.
  2. Fuel line blocked, or stale fuel.
  3. Water or dirt in fuel system.
  4. Carburetor out of adjustment.
  5. Over-governed engine.
  1. Move choke lever to RUN position.
  2. Clean fuel line and fill tank with fresh, clean gasoline.
  3. Run engine until it stops. Refill with fresh fuel.
  4. Contact your Sears Parts & Repair Center.
  5. Contact your Sears Parts & Repair Center.

Excessive vibration

  1. Loose parts or damaged auger.
  1. Stop engine immediately and disconnect spark plug wire. Tighten all bolts and nuts. If vibration continues, have unit serviced by a Sears Parts & Repair Center.

Loss of power

  1. Spark plug wire loose.
  2. Gas cap vent hole plugged.
  1. Connect and tighten spark plug wire.
  2. Remove ice and snow from gas cap. Be certain vent hole is clear.

Unit fails to propel itself

  1. Drive cable in need of adjustment.
  2. Drive belt loose or damaged.
  1. Adjust drive control cable. Refer to Service and Maintenance section.
  2. Replace drive belt. Refer to Service & Maintenance section.

Unit fails to discharge snow

  1. Chute assembly clogged.
  2. Foreign object lodged in auger.
  3. Auger cable in need of adjustment.
  4. Auger belt loose or damaged.
  5. Shear pin(s) sheared.
  1. Stop engine immediately and disconnect spark plug wire. Clean chute assembly and inside of auger housing with clean-out tool.
  2. Stop engine immediately and disconnect spark plug wire. Remove object from auger with clean-out tool.
  3. Adjust auger control cable. Refer to Assembly section.
  4. Replace auger belt. Refer to Service and Maintenance section.
  5. Replace with new shear pin(s).

www.craftsman.com

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Craftsman 247.881980 Troubleshooting Manual

Advertisement

Need help?

Need help?

Do you have a question about the 247.881980 and is the answer not in the manual?

Questions and answers

Table of Contents