Debugging Operation

4-2 Debugging Operation

4-2-1 CS/CJ/CP-series PLC's Modes and Execution Mode

Relationship between Actual PLC's Modes and Execution Mode
Mode Change from CX-Programmer
Execution mode and CX-Simulator Connection
The Ladder Engine has the execution mode for operating from the
[CX-Simulator Debug Console] as well as the modes in the CS/CJ/CP-series
PLC. Changing the execution mode from the [CX-Simulator Debug Console]
allows more detailed debugging.
The Ladder Engine of the CX-Simulator performs the same operation as the
actual PLC. Thus it has the actual PLC's modes (Program/Monitor/Run).
The table below shows the relationship between the actual PLC's modes and
the Execution Mode
Execution Mode
Scan
Scan Run
Run
Continuous Scan Run
Continuous Run
Step
Step Run
Run
Continuous Step Run
Pause
Stop
Scan Replay
Reset
Note The Ladder Engine runs in the Monitor mode. A Run operation turns the mode
to Monitor even when the mode is changed to Run from the CX-Programmer.
Changing the mode from the CX-Programmer will change the execution mode
of the Ladder Engine as follows.
• Program mode → Monitor/Run mode
• Monitor/Run mode → Program mode
• Monitor mode → Run mode
• Run mode → Monitor mode
Selecting [Disconnect] in the [Work CX-Simulator] window will automatically
turn the execution mode to the Stop mode. Changing the execution mode from
the [CX-Simulator Debug Console] or changing the mode from the
CX-Programmer can not be performed during Disconnect.
Change the execution mode after [Connect].
Mode
Program
Monitor
Mode
mode
Follow the settings.
: Continuous Run
: Stop mode
: No change
: No change
Section 4-2
Run mode
Same as the Moni-
tor mode.
Changed only by the
CX-Programmer
setting.
103