Terminal Plate; Wiring Method - Omron WLM Datasheet

Long-life two-circuit limit switch
Table of Contents

Advertisement

Wiring
Use 1.25-mm lead wires and M4-insulation covered crimp terminals
for wiring.
Crimp Terminal External Dimensions
D dia.
dz dia. 4.3
D dia.
4.5
B:
8.5
L:
21.0
F:
7.8
l:
9.0 (mm)

Wiring Method

Switch Box Section
Ground terminal
NO terminal
NC terminal
Note: Ground terminals are not installed on the standard models.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. C112-E1-02
F-108
Long-life Two-circuit Limit Switch
dz dia.
In the interest of product improvement, specifications are subject to change without notice.
WLM@
Operation Set Position
There is a set position marker slit on the rubber cap of the head.
After operation, set the slit on the rubber cap so that the fluorescent
color on the shaft section can be seen.

Terminal Plate

By using a short circuit plate, as shown in the following diagram, the
Switch can be fabricated into a single-polarity double-break model.
When ordering specify WL Terminal-Plate (IWPA01).
.
9+
16±
0.2
2.1R
3R
0.15
2R
t = 0.6 Copper plate

Advertisement

Table of Contents
loading

Table of Contents