Screwless clamp terminal socket

Advertisement

Quick Links

Screwless Clamp Terminal Socket
PYF@@S
• Screwless clamping greatly contributes to reducing wiring time.
• No over or under tightening of cable connection so better con-
tact reliability is achieved.
• Double wiring possible on all the terminals, and easy bridge and
branch connections.
• Use either solid or stranded wires from 0.2 to 1.5 mm
to AWG16).
• Safe terminal arrangement: Coil terminals separated from con-
tact terminals.
• Unique ejector enables easy relay replacement.
• Nameplate available
• Finger-protection
Ordering Information
■ List of Models
Socket
Clip & Release Lever
Nameplate
Socket Bridge
Specifications
■ Ratings/Characteristics
Item
Relay
Dimensions
Rated voltage
Rated carry current
Applicable wires
Number of wire connections
Clamping force
■ Approved Standards
Standard
VDE0627 (IEC664, EN60999)
UL508 (UL1059)
CSA C22.2 No. 14 (CSA C22.2 No. 158)
2
(AWG24
4-pole for MY4/MY2
PYF14S
PYCM-14S
PYDM-14SR, PYDM-14SB
PYF14S
MY2 Series
MY4 Series
31 × 85 × 36.5 mm max. (W × H × D)
10 A at 55°C with MY2 (S)
7 A at 70°C with MY2 (S)
5 A at 70°C with MY4 (S)
0.2 to 1.5 mm
2 wires per terminal (1 wire per hole)
File No.
112467UG
E87929 Vol. 3
LR31928
PYF08S
PYCM-08S
R99-11
PYDM-08SR, PYDM-08SB
MY2 Series
23.2 × 85 × 36.5 mm max. (W × H × D)
250 VAC
10 A at 55°C with MY2 (S)
7 A at 70°C with MY2 (S)
2
(AWG24 to AWG16)
Solid wire
Stranded wire
10 N min. (0.2 mm
2
)
40 N min. (1.5 mm
2
)
Screwless Clamp Terminal Socket
2-pole for MY2
PYF08S
---
---
---
VDE0627
---
---
EN60999
PYF@@S
Remarks
1

Advertisement

loading

Summary of Contents for Omron PYF S

  • Page 1 Screwless Clamp Terminal Socket PYF@@S • Screwless clamping greatly contributes to reducing wiring time. • No over or under tightening of cable connection so better con- tact reliability is achieved. • Double wiring possible on all the terminals, and easy bridge and branch connections.
  • Page 2: Terminal Arrangement

    PYF14S PYF08S Common contacts Make contacts Break contacts Coil Note: In case MY2 relay will be used in combination with PYF14S terminals 21, 22, 24 and 31, 32, 34 are not connected. Mounting Height (With Lever) PYF14S PYF08S 73.6 typ.
  • Page 3: Installation

    (AEF. 3 × 75E) Examples: VESSEL No. 9900-(-)2.5 × 75 (No. 9900-(-)3 × 100) WAGO 210-119 WIHA 260/2.5 × 40 (260/3 × 50) *Chamfering the tip of the driver improves insertion when used as an exclusive tool. PYF@@S Screwless Clamp Terminal Socket...
  • Page 4: Applicable Wires

    Applicable Wire Type Solid wires, stranded wires, flexible wires, or wires with ferules can Note: 1. If the outer diameter D of the wire is less than 2.2 mm and be used. the exposed conductor length is less than 8 mm potentially bad connection might occur in case wire is pushed to far in- (See note 1.) <...
  • Page 5: Precautions For Connection

    ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. Cat. No. J122-E2-04-X...

This manual is also suitable for:

Pyf14sPyf08s