FHSCP-UNV-16W-L-SD-HV
Emergency LED Driver

Emergency LED Driver
Universal Voltage: 120-305VAC, 50/60Hz
Output Voltage Range: 120-300V
Output Current: 53-134mA
Input Voltage / Frequency
Input Current
Input Power
Standby Power
Input Power Pass-Through Rating (AC Driver Line)
Max Output Rating (LED+ LED- Terminal)
Driver Type
Output Current Rated
Output Voltage Range
Output Power
Number of Output Channels
Input Surge Protection
RFI/ EMI
Output Type
Battery Type
Battery Voltage
Battery Capacity Available
Battery Rating
Battery Recharge Time
Battery Discharge Time
Rated Ambient (ta)
Protections
Sound Rating
Humidity
Safety Standards
Service Life
Warranty
Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: 1-323-779-2980 Fax.: 1-323-754-9060.
Specifications subject to change without notice.
Output Wattage: 16W
Output Type: No-Class 2
 Number of Output Channels: 1 Channel
 Dry and Damp
120-305VAC , 50/60Hz
0.12A
6.5W Max
<0.85W
5A
2A, 300V Max
Constant Power
134mA Max.
100 - 300VDC
Typical 16W
1 Channel
3KV/6KV Ring wave
FCC Part 15A
No-Class 2
Ternary Lithium Battery
10.95V
5000mAh
54.75Wh
24 Hours Max
TBD
1.5 Hours Min.
0°C to 55°C (32°F to 131°F)
Over / Under Voltage Protection
Overload Protection
Output Open Circuit Protection
A
5% - 95%
UL 924, UL 1310, CSA C22.2 No.141-10
50,000 Hours
5 Years From the date of manufacture when properly installed
order@fulham.com www.fulham.com
2023-XXX Rev A
Page 1 of 7

Advertisement

loading
Need help?

Need help?

Do you have a question about the FIREHORSE HOTSPOT FULHAM FHSCP-UNV-16W-L-SD-HV and is the answer not in the manual?

Questions and answers

Summary of Contents for Fulham FIREHORSE HOTSPOT FULHAM FHSCP-UNV-16W-L-SD-HV

  • Page 1 Service Life Warranty 5 Years From the date of manufacture when properly installed Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: 1-323-779-2980 Fax.: 1-323-754-9060. order@fulham.com www.fulham.com Specifications subject to change without notice. Page 1 of 7...
  • Page 2: Mechanical Data

    1.34" Height (34mm) 9.45" [240mm] 9.10" [231mm] 8.8" [224mm] FHSCP-UNV-16W-L-SD-HV Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: 1-323-779-2980 Fax.: 1-323-754-9060. order@fulham.com www.fulham.com Specifications subject to change without notice. Page 2 of 7 2023-XXX Rev A...
  • Page 3 1.“Charge push to Test”plate white with black lettering 2. (2) 6-32 x ½”LG mounting screws Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: 1-323-779-2980 Fax.: 1-323-754-9060. order@fulham.com www.fulham.com Specifications subject to change without notice. Page 3 of 7...
  • Page 4: Wiring Diagram

    BATTERY CONNECTOR RED (Form LED driver) BLU/WHT RED/WHT LEDARRAY Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: 1-323-779-2980 Fax.: 1-323-754-9060. order@fulham.com www.fulham.com Specifications subject to change without notice. Page 4 of 7 2023-XXX Rev A...
  • Page 5 Press and hold the test switch for 3 seconds during EM output condition to turn off EM output. This is useful for production environment to turn off the EM output once a luminaire has completed functionality testing. Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: 1-323-779-2980 Fax.: 1-323-754-9060. order@fulham.com www.fulham.com Specifications subject to change without notice.
  • Page 6 LED Load • Fulham’s Hotspot Constant Power Emergency LED drivers are designed to drive passive LED’s, COB’s and LED assemblies. Proper function is not guaranteed when (LED) loads with active components are used. Mounting and cooling •...
  • Page 7: Outer Dimension

    - 1 6 QUANTITY L - S D - H Weight Weight Fulham Co. Inc.: 12705 South Van Ness Ave., Hawthorne, CA 90250 Tel.: 1-323-779-2980 Fax.: 1-323-754-9060. order@fulham.com www.fulham.com Specifications subject to change without notice. Page 7 of 7 2023-XXX Rev A...

This manual is also suitable for:

Firehorse hotspot fhups1-unv-50l-sdFirehorse hotspot fhscp-unv-15p-s-sdFirehorse hotspot fhscp-unv-16w-l-sd-hvFirehorse hotspot fhcs-unv3-20p-40c