Omron NQ HMI Getting Started Manual page 41

Nq-series hmi
Table of Contents

Advertisement

Using NQ-Designer
Register
Tag name
s0017
Invalid key beeper
s0019
Invalid date entry
s0020
Popup screen control coil Read/Write
s0021
Communication recover
enable bit: port1
s0028
Bittask datalogger-logger
group1 bit
s0029
Bittask datalogger-logger
group2 bit
s0030
Bittask datalogger-logger
group3 bit
s0031
Bittask datalogger-logger
group4 bit
s0032
Lock data entry
Read/Write
Description
Read/Write
0: disable valid screen
beeper
1: enable valid screen
beeper.
When set to 0 the NQ-
Series will only generate
a beep when an input
area is pressed.
This bit can be changed
during operation
Read
0: valid date
1: invalid date (range
not within defined
ranges e.g. month > 12)
Triggers the popup
screen number stored in
S0023
Read/Write
If this bit is set
communication with the
failed nodes is detected
after scan time S0018
for port1 (on by default)
Read/Write
User can start/stop
logging in bit task mode
for group1 by using this
bit.
1: Start logging
0: Stop logging
Read/Write
User can start/stop
logging in bit task mode
for group2 by using this
bit.
1: Start logging
0: Stop logging
Read/Write
User can start/stop
logging in bit task mode
for group3 by using this
bit.
1: Start logging
0: Stop logging
Read/Write
User can start/stop
logging in bit task mode
for group4 by using this
bit.
1: Start logging
0: Stop logging
Read/Write
User can lock/unlock
the data entry (keypad
entry).
0: data entry unlock
1: data entry lock
Section 4-2
27