Note
Communication parameters defined on the unit's COM1 port and in the PLC settings should match.
Node ID Set in NQ-Designer node information and communications setup settings from the PLC settings
should match.
PLC cable connected between PLC port and NQ-Series' COM port should be selected correctly.
Cable should be connected correctly.
Select a correct tag address and the same tag should be embedded on the unit screen.
The following messages are displayed on the unit screen if the notes above are not taken into consideration:
!!! no connection
??? connection established, address unknown
119