Specifications

Ratings
Item
Control supply voltage
Rated frequency
Carry current
Operating voltage range
Voltage fluctuation compensation
range
Operating current
Releasing current
Operate time
Gate input voltage range (for
models with gate input terminals)
Control output
Power consumption
Characteristics
Setting accuracy
Repeat accuracy
Influence of temperature
Influence of voltage
Influence of frequency
Insulation resistance
Dielectric strength
Overcurrent
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight
Note: The logical value is an operating value within a range of 0.85 to 1.1 with a voltage fluctuation of 85% to 110%, based on the value at the
control supply voltage measured as 1.
2
K2CU-F
100, 110, 200, 220 VAC
50/60 Hz
1.25 times as large as each model's
maximum operating current
85% to 110% of control supply voltage
85% to 110% of control supply voltage
4 to 10 A, 8 to 20 A, 16 to 40 A, 32 to 80 A
(continuously variable)
105% max. of operating current
0.5 s max. (when current changes from 150% to 0%)
5 to 30 VDC
2 A at 220 VAC, SPDT (cosφ = 0.4)
Input: 0.5 VA max.
Power supply: 5 VA max.
±7% max.
±3% max.
±10% max. (at 20°C±30°C)
Models without voltage fluctuation compensation:
±3% max. of the value measured at the control supply voltage, on condition that the voltage
fluctuation is 85% to 110% of the control supply voltage
Models with voltage fluctuation compensation:
±5% max. of the logical value, on condition that the voltage fluctuation is 85% to 110% of the
control supply voltage. (see note)
±3% max. (at ±5% of rated frequency)
10 MΩ min. (at 500 VDC) between electric circuits and mounting panel
2,000 VAC, 50/60 Hz for 1 min between electric circuits and mounting panel
20 times of max. set value of operating current for 2 s
Destruction: 16.7 Hz, 1-mm double amplitude for 10 min each in X, Y, and Z directions
2
Destruction: 100 m/s
(approx. 10G)
Operating: –10°C to 55°C (with no icing)
Operating: 45% to 85%
K2CU-F: approx. 390 g; K2CU-P: approx. 300 g
K2CU-P
100/200, 110/220 VAC
2.5 A for K2CU-P0.5A-A/-B;
5 A
85% to 110% of control supply voltage
(applicable only on models with voltage
fluctuation compensation)
0.25 to 0.5 A, 0.5 to 1 A, 1 to 2 A, 2 to 4 A
(continuously variable)
110% max. of operating current
---
Input: 1 VA max.
Power supply: 4 VA max.
K2CU