Omron H8PS Manual page 28

Cam positioner
Hide thumbs Also See for H8PS:
Table of Contents

Advertisement

Pulse Output (f1/f2)
Outputs a preset number of pulses per Encoder rotation. Pulses are
output at a 1:1 ON/OFF ratio and pulse output can be started from a
specified angle.
Operation for 9 Output Pulses and a Start Angle of 0
1
2
3
4
5
0
90
180
Output start angle
Operation for 9 Output Pulses and a Start Angle of 10
1
2
3
4
0 10
90
180
Output start angle
Number of Output Pulses (f1)
Select the number of pulses per rotation from the following table.
Encoder resolution
256
1, 2, 3, 4, 5, 6,
30, 36,
360
1, 2, 3, 4, 5, 6,
30, 36,
720
1, 2, 3, 4, 5, 6, 8, 9, 10, 12, 15, 18, 20, 24,
30, 36, 40, 45,
Note: Default settings are shown in reverse type.
Example: Setting 90 Pulses per Rotation
The number of pulses is set using the F1 menu in the Function
Setting Mode.
Setting Display
PRG
Set the number of pulses with the
ANGLE Keys
WRITE
STEP
CAM
Pulse Output Start Angle (f2)
The setting ranges are given in the following table.
Encoder
Resolution
Display
angle
256
256
0
to 255
256
360
0
to 359 (See note 2.)
360
---
0
to 359
720
---
0
to 359.5
Note: 1. Default settings are shown in reverse type.
2. The output accuracy is 2 maximum, so not all angles can
be set.
Example: Setting the Pulse Output Start Angle to 100
The starting angle for pulse outputs is set using the F2 menu in the
Function Setting Mode.
Setting Display
PRG
Set the pulse output start angle to 100
with the ANGLE Keys
press the
CAM
STEP
28
Cam Positioner
6
7
8
9
270
5
6
7
8
9
270
Settable number of pulses
9, 10, 12, 15, 18, 20,
45,
60
,
90
9, 10, 12, 15, 18, 20,
45,
60
,
90,
180
60
, 72, 90, 120, 180, 360
and then press the
Key.
Start angle
and then
Key.
WRITE
H8PS
Speed Alarm Outputs (f3/f4)
Specific cam outputs can be used as Encoder speed alarm outputs.
Alarms can be output for upper and lower speed limits.
Upper limit SV
Lower limit SV
0
Upper Limit Alarm Output
Lower Limit Alarm Output
The speed alarm outputs are assigned to cam outputs as shown in
the following table. The speed alarms are set to "- - -" for the default
0
settings, i.e., the normal cam outputs are enabled. If a speed alarm is
set to any value but "- - -", the normal cam output for the
corresponding cam number will be disabled.
H8PS-8@ (8 outputs)
H8PS-16@ (16 outputs) Cam 15
H8PS-32@ (32 outputs) Cam 31
The setting ranges for the upper and lower limits speed alarm are
given in the following table.
Encoder resolution
256, 360
720
Note: Default settings are shown in reverse type.
Speed Alarm Upper Limit (f3)
Example: Setting the Upper Limit Set Value to 700 r/min for a 16-
output Model
The upper limit set value is set using the F3 menu in the Function
Setting Mode.
Upper Limit Setting Display
STEP
CAM
Note: If banks are being used, the bank number must be set.
Speed Alarm Lower Limit (f4)
Example: Setting the Lower Limit Set Value to 20 r/min for a 16-
output Model
The lower limit set value is set using the F4 menu in the Function
Setting Mode.
Lower Limit Setting Display
STEP
CAM
Note: If banks are being used, the bank number must be set.
Speed
Upper Limit
Lower Limit
Alarm Output
Alarm Output
Cam 7
Cam 8
Cam 16
Cam 32
Speed
"
- - -
" or 0 to 1,600 r/min
"
- - -
" or 0 to 800 r/min
PRG
Set the upper limit set value to 700 with
the ANGLE Keys
and then press
the
Key. (See note.)
WRITE
PRG
Set the upper limit set value to 20 with
the ANGLE Keys
and then press
the
Key.
WRITE