Omron F250-UME Software Manual page 366

Table of Contents

Advertisement

EC Defect
CHECK
2-15-(33)
Only parallel lines that match the set defect width and length will be detected
as defects. Width and length conditions can be set to exclude measurement
outlines from being detected as defects, even if the outline is box-shaped and
the edges are parallel.
1.
Select Inspected regions.
1.EC defect
A list of inspected regions will be displayed.
Inspected regions
2.
Select a region number.
The measurement method selections will be displayed.
3.
Select Defect.
The initial Defect Screen will be displayed.
4.
Select Measurement conditions.
The Measurement Conditions Settings Screen will be displayed.
Measurement conditions
Measurement image
Extract edges
Removal regions
Removal image
Inspected regions
Coordinate mode
Region0
Region1
Region2
Region3
Region4
Region5
Region6
Region7
Defect
Labeling
Gravity and area
Measurement conditions
Inspected region
Clear
Extracting level :
Defect color
:
Defect width
: [
1:10]pix
Defect length
: [
1:50]pix
End
Section 2-15
3
Black

Advertisement

Table of Contents
loading