Power Supply and Ground
2-4-2

Protective Conductor (Earth) Wiring

!Caution
Class I
(with protective conductor
terminal)
2-4-3

Wiring the Power Supply

!Caution
Power Supplies
Applicable wire size: Insulated wire of 1.31 to 1.65 mm
(AWG16 to AWG15)
Wire the ground as shown in the following diagram.
Use an appropriate ground. An insufficient ground can
affect F150 operation or result in damage to F150 compo-
nents.
• To avoid damage to the equipment, do not share the pro-
tective conductor wiring with any other devices nor wire
the protective conductor terminal to the girder. Be sure to
wire the protective conductor of the equipment indepen-
dently.
• Keep the ground line as short as possible.
Use DC power supplies with safe extra low-voltage circuits
that prevent occurrences of high voltages in the main
F150 power supply and power supplies for the terminal
blocks.
Use a power supply with the following specifications. We rec-
ommend using OMRON's S82K-01524 Power Supply.
Item
Output current
Power supply voltage
When connecting the F150, Two-camera Unit, and F150-
M05L LCD Monitor to a single power supply, use a power sup-
ply that meets the following specifications. We recommend
using OMRON's S82K-05024 Power Supply.
Specification
0.6 A min.
+10%
24 VDC
/
-15%