• Status LED – The status LED is only visible from the top of the sensor:
4-2-3 Push buttons on the sensor
On the sensor, there are three push buttons for the setting of the sensor:
•
Minus key
•
Plus key
•
Enter key
With these three push buttons, the operator moves through the sensor's menu and sets the parameters in
accordance with the application. Therefore, all parameters can be set directly on the sensor.
4-2-4 Set-up via a PC
All parameters of the sensor can be set also with a PC (or Laptop) and the OMRON SensorSupportSoftware
S3. The connection between the sensor and the PC is established via an optical data interface (E3NT-AL232
2m). The data interface is connected to a free COM port of a PC/laptop. Also the USB – RS232 Converter of
OMRON can be used to realize the connection. Refer to the separate operating instructions ABBO0018 for
further information on setting with a PC and the SensorSupportSoftware S3 .
4-3 User set parameters
The following parameters can be user set either by push buttons on the sensor or with a PC and the set-up
software S3 via the optical data interface (order separately):
•
Output function
•
Output switching
•
Function on connector pins 2 and 5
•
Switch-on and off delay
•
Type of time delay function
•
Keyboard lock
•
Energy saving mode
•
Display direction
•
Reset to factory defaults
The following functions can only be set with a PC and the set-up software S3 via the optical data interface
(order separately):
•
Complete sensor locking
4-3-1 Output function
The output function can be set for the output:
•
Light on (factory default):
The output is active when the reflected light is detected at the receiver.
•
Dark on:
The output is active when no reflected light is detected at the receiver.
16
ON:
Set-up menu selected
Blinking:
Menu level with change
OFF:
RUN (normal) mode
SECTION 4: Function