Download Print this page

Dimensions (Unit: Mm) - Omron E3S-C Datasheet

Oil-resistive, compact photoelectric sensor in metal housing
Hide thumbs Also See for E3S-C:

Advertisement

Optical axis position of through-beam model
Unlike the conventional product, the through-beam model has
two lenses, but the one actually used is as shown below.
When fitting the slit, use it after matching the slit hole with the
used lens.
(Horizontal model) (Vertical model)
Lens in use.
The slit must be on this side.
Lens not in use.
Water Resistance
To ensure water resistance, tighten the operation panel cover
screws to 0.34 Nm to 0.54 Nm torque.

Dimensions (Unit: mm)

Sensors
Through-beam model (horizontal model)
E3S-CT11(-M1J)
Emitter: E3S-CT##-L
Receiver: E3S-CT##-D
Lens (17 x 11)
Optical axis
23
( A ) *
1
2-M4
* Note: 1. Mounting bracket can be attached to side A.
2. The emitter for through-beam sensors have only the power supply indicator.
3. The cable for emitters for through-beam sensors is two-conductor, 4 dia. (27 x 12 dia.).
A-108
Lens in use.
Lens not in use.
With mounting bracket
50
18.5
22.2
Stability
indicator
(green)
9.2
6.2
2.2
4
18
9.3
20.8
1.5
Miscellaneous
Oil resistance/chemical resistance
• Though E3S-C has a high oil resistance, it may not be able
to exhibit its performance depending on the oil type. Use oil
in compliance with the following table.
• Regarding the oil resistance of E3S-C, it has passed tests
on the oils given in the following table. Refer to the table for
examining the oil to be used.
Testing
JIS classi-
oil classi-
fication
fication
Lubricant
---
Class 2
Water-in-
No. 5
soluble
coolant
Class 2
No. 11
Class W1
No. 1
Water-
Class W1
soluble
No. 2
coolant
Class W2
No. 1
Note: 1 . The E3S-C was immersed in the oils in the above table at 50°C for 240
hours, and passed the test of 100-M or more insulation resistance.
2 . For use in the environment where the E3S-C is exposed to the oil other
than those in the above table, use the dynamic viscosity and PH in the
above table. Pre-examine the oils since the sensor may be affected by
additives and like in the oils.
Vinyl-insulated round cable with
three conductors, 4 dia.
(18 x 0.12 dia.); standard length: 0.3 m
M3 x 5
Vinyl-insulated round cable with
three conductors, 4 dia.
* 2
(18 x 0.12 dia.); standard length: 2 m * 3
Light indicator (red)
20
20.4
20
4.2
4.2
8.3
Stainless steel
(SUS304)
38.2
29.5
17.3
25.4
Dynamic vis-
Product name
cosity (mm
at 40°C
Velocity No. 3
2.02
Not less than
Daphne Cut
10 to less than
50
Yushiron Oil No. 2ac
Less than 10
Yushiroken EC50T-3
Yushiron Lubic HWC68
---
Gryton 1700D
Yushiroken S50N
Junction connector models (-M1J)
M12 x 1
16 dia.
Mounting holes
2-M4
25.4
Standard Photoelectric Sensors
2
/s)
PH
---
7 to 9.5
7 to 9.9
7 to 9.2
7 to 9.8

Advertisement