Fluid level sensor (contact type)
E32-D82F
High-accuracy detection of
fluid level in washing tank.
● Uses Teflon (PFA) with excellent chemical and oil
resistance.
● Capable of detecting high-temperature fluids
such as sulfuric acid in a wafer washing tank.
(-40 to +200°C)
● Achieves a high repetition precision of 0.5 mm
(in pure water).
● Employs a dripping prevention mechanism.
Ordering Information
Fiber Units
Sensor type
Shape
Diffuse-reflective
Rating/performance
Sensor type
Item
Model
Standard sensing object
Differential distance
Repetition precision
Permissible angle of detection
object inclination
Perim-
Teflon section within
eter
1.5 m of fiber tip*1
Tem-
Parts other than the
pera-
above
ture
Ambient humidity
Peripheral pressure
Admissible bending radius
(10% under fluid level)
Length of no-
average)
bending section
Sensor case
Material
Fiber cladding
Connector
Protective structure
Weight (Packed state)
Accessories
*1. Teflon is a registered trademark of Dupont Company and Mitsui Dupont Chemical Company for their
fluoride resin.
*2. Only applies to Teflon section; the standard requires no bubbling when air at 98 kPa is injected for 30 sec-
onds at a depth of 100 mm in water.
E32-D82F
Model
Length of no-bending section:
E32-D82F1
150 mm from tip
Length of no-bending section:
E32-D82F2
350 mm from tip
Diffuse-reflective
E32-D82F1
Pure water at 25°C
3 mm max.
0.5 mm or less
±10° or less
Operating: -40 to +200°C, Storage: -40°C to +85°C
(with no icing or condensation)
Operating/storage: -40 to +85°C
(no ice formation or condensation)
Operating/storage: 35 to 85% RH
Operating: -50 kPa to 500 kPa
40 mm or higher (25 mm for plastic fiber section)
150 mm from tip
350 mm from tip
Teflon (PFA)
Black polyethylene
Brass-nickel coating
IEC Standard IP68*2
Approx. 75 g
Fiber cutter
Applicable amplifier unit
Remarks
E3X-DA-N
E3X-NA
Principle of operation
E32-D82F2
• In air, the difference between the index
of refraction of the Teflon section and
that of air is larger, and the light is
reflected by the detected surface and
returns to the light receiver.
• In the fluid, there is almost no difference
between the index of refraction of the
Teflon section and that of the fluid, and
the light radiates into the fluid.
Model
Air
Liquid
A-361

Advertisement

loading

Summary of Contents for Omron E32-D82F

  • Page 1 *1. Teflon is a registered trademark of Dupont Company and Mitsui Dupont Chemical Company for their fluoride resin. *2. Only applies to Teflon section; the standard requires no bubbling when air at 98 kPa is injected for 30 sec- onds at a depth of 100 mm in water.
  • Page 2 2,000 * 1. ( ): E32-D82F2 dimensions * 2. Freely cut because 2m part of optical fiber at amplifier side is made from a plastic fiber. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.